Sample preparation: the weak link in microfluidics-based biodetection
As a broad generalization, clinicians and laboratory personnel who use microfluidics-based automated or semi-automated instrumentation to perform biomedical assays on real-world samples are more pleased with the state of the assays than they are with the state of the front-end sample preparation. Th...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7088034/ https://www.ncbi.nlm.nih.gov/pubmed/18483862 http://dx.doi.org/10.1007/s10544-008-9190-7 |
_version_ | 1783509457698816000 |
---|---|
author | Mariella, Raymond |
author_facet | Mariella, Raymond |
author_sort | Mariella, Raymond |
collection | PubMed |
description | As a broad generalization, clinicians and laboratory personnel who use microfluidics-based automated or semi-automated instrumentation to perform biomedical assays on real-world samples are more pleased with the state of the assays than they are with the state of the front-end sample preparation. The end-to-end procedure requires one to collect, manipulate, prepare, and analyze the sample. The appeal of microfluidics for this procedure is partly based on its combination of small size and its ability to process very small liquid volumes, thus minimizing the use of possibly expensive reagents. However, real-world samples are often large and incompatible with the input port and the μm-scale channels of a microfluidic device, and very small liquid volumes can be inappropriate in analyzing low concentrations of target analytes. It can be a worthy challenge to take a raw sample, introduce it into a microfluidics-based system, and perform the sample preparation, which may include separation and concentration of the target analytes, so that one can benefit from the reagent-conserving small volumes and obtain the correct answer when finally implementing the assay of interest. |
format | Online Article Text |
id | pubmed-7088034 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-70880342020-03-23 Sample preparation: the weak link in microfluidics-based biodetection Mariella, Raymond Biomed Microdevices Article As a broad generalization, clinicians and laboratory personnel who use microfluidics-based automated or semi-automated instrumentation to perform biomedical assays on real-world samples are more pleased with the state of the assays than they are with the state of the front-end sample preparation. The end-to-end procedure requires one to collect, manipulate, prepare, and analyze the sample. The appeal of microfluidics for this procedure is partly based on its combination of small size and its ability to process very small liquid volumes, thus minimizing the use of possibly expensive reagents. However, real-world samples are often large and incompatible with the input port and the μm-scale channels of a microfluidic device, and very small liquid volumes can be inappropriate in analyzing low concentrations of target analytes. It can be a worthy challenge to take a raw sample, introduce it into a microfluidics-based system, and perform the sample preparation, which may include separation and concentration of the target analytes, so that one can benefit from the reagent-conserving small volumes and obtain the correct answer when finally implementing the assay of interest. Springer US 2008-05-16 2008 /pmc/articles/PMC7088034/ /pubmed/18483862 http://dx.doi.org/10.1007/s10544-008-9190-7 Text en © Springer Science+Business Media, LLC 2008 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic. |
spellingShingle | Article Mariella, Raymond Sample preparation: the weak link in microfluidics-based biodetection |
title | Sample preparation: the weak link in microfluidics-based biodetection |
title_full | Sample preparation: the weak link in microfluidics-based biodetection |
title_fullStr | Sample preparation: the weak link in microfluidics-based biodetection |
title_full_unstemmed | Sample preparation: the weak link in microfluidics-based biodetection |
title_short | Sample preparation: the weak link in microfluidics-based biodetection |
title_sort | sample preparation: the weak link in microfluidics-based biodetection |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7088034/ https://www.ncbi.nlm.nih.gov/pubmed/18483862 http://dx.doi.org/10.1007/s10544-008-9190-7 |
work_keys_str_mv | AT mariellaraymond samplepreparationtheweaklinkinmicrofluidicsbasedbiodetection |