A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves
An inexpensive, disposable, integrated, polymer-based cassette for loop-mediated isothermal amplification (LAMP) of target nucleic acids was designed, fabricated, and tested. The LAMP chamber was equipped with single-use, thermally actuated valves made with a composite consisting of a mixture of PDM...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer-Verlag
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7088409/ https://www.ncbi.nlm.nih.gov/pubmed/32214952 http://dx.doi.org/10.1007/s10404-011-0788-3 |
_version_ | 1783509535691898880 |
---|---|
author | Liu, Changchun Mauk, Michael G. Bau, Haim H. |
author_facet | Liu, Changchun Mauk, Michael G. Bau, Haim H. |
author_sort | Liu, Changchun |
collection | PubMed |
description | An inexpensive, disposable, integrated, polymer-based cassette for loop-mediated isothermal amplification (LAMP) of target nucleic acids was designed, fabricated, and tested. The LAMP chamber was equipped with single-use, thermally actuated valves made with a composite consisting of a mixture of PDMS and expandable microspheres. The effect of the composite composition on its expansion was investigated, and the valve’s performance was evaluated. In its closed state, the valve can hold pressures as high as 200 kPa without any significant leakage. Both the LAMP chamber and the valves were actuated with thin film heaters. The utility of the cassette was demonstrated by carrying out LAMP of Escherichia coli DNA target and reverse transcribed loop meditated isothermal amplification (RT-LAMP) of RNA targets. The amplicons were detected in real time with a portable, compact detector. The system was capable of detecting as few as 10 target molecules per sample in well under 1 h. The portable, integrated cassette system described here is particularly suited for applications at the point of care and in resource-poor countries, where funds and trained personnel are in short supply. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10404-011-0788-3) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-7088409 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Springer-Verlag |
record_format | MEDLINE/PubMed |
spelling | pubmed-70884092020-03-23 A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves Liu, Changchun Mauk, Michael G. Bau, Haim H. Microfluid Nanofluidics Research Paper An inexpensive, disposable, integrated, polymer-based cassette for loop-mediated isothermal amplification (LAMP) of target nucleic acids was designed, fabricated, and tested. The LAMP chamber was equipped with single-use, thermally actuated valves made with a composite consisting of a mixture of PDMS and expandable microspheres. The effect of the composite composition on its expansion was investigated, and the valve’s performance was evaluated. In its closed state, the valve can hold pressures as high as 200 kPa without any significant leakage. Both the LAMP chamber and the valves were actuated with thin film heaters. The utility of the cassette was demonstrated by carrying out LAMP of Escherichia coli DNA target and reverse transcribed loop meditated isothermal amplification (RT-LAMP) of RNA targets. The amplicons were detected in real time with a portable, compact detector. The system was capable of detecting as few as 10 target molecules per sample in well under 1 h. The portable, integrated cassette system described here is particularly suited for applications at the point of care and in resource-poor countries, where funds and trained personnel are in short supply. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10404-011-0788-3) contains supplementary material, which is available to authorized users. Springer-Verlag 2011-03-18 2011 /pmc/articles/PMC7088409/ /pubmed/32214952 http://dx.doi.org/10.1007/s10404-011-0788-3 Text en © Springer-Verlag 2011 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic. |
spellingShingle | Research Paper Liu, Changchun Mauk, Michael G. Bau, Haim H. A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves |
title | A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves |
title_full | A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves |
title_fullStr | A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves |
title_full_unstemmed | A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves |
title_short | A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves |
title_sort | disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7088409/ https://www.ncbi.nlm.nih.gov/pubmed/32214952 http://dx.doi.org/10.1007/s10404-011-0788-3 |
work_keys_str_mv | AT liuchangchun adisposableintegratedloopmediatedisothermalamplificationcassettewiththermallyactuatedvalves AT maukmichaelg adisposableintegratedloopmediatedisothermalamplificationcassettewiththermallyactuatedvalves AT bauhaimh adisposableintegratedloopmediatedisothermalamplificationcassettewiththermallyactuatedvalves AT liuchangchun disposableintegratedloopmediatedisothermalamplificationcassettewiththermallyactuatedvalves AT maukmichaelg disposableintegratedloopmediatedisothermalamplificationcassettewiththermallyactuatedvalves AT bauhaimh disposableintegratedloopmediatedisothermalamplificationcassettewiththermallyactuatedvalves |