Cargando…

A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves

An inexpensive, disposable, integrated, polymer-based cassette for loop-mediated isothermal amplification (LAMP) of target nucleic acids was designed, fabricated, and tested. The LAMP chamber was equipped with single-use, thermally actuated valves made with a composite consisting of a mixture of PDM...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Changchun, Mauk, Michael G., Bau, Haim H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer-Verlag 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7088409/
https://www.ncbi.nlm.nih.gov/pubmed/32214952
http://dx.doi.org/10.1007/s10404-011-0788-3
_version_ 1783509535691898880
author Liu, Changchun
Mauk, Michael G.
Bau, Haim H.
author_facet Liu, Changchun
Mauk, Michael G.
Bau, Haim H.
author_sort Liu, Changchun
collection PubMed
description An inexpensive, disposable, integrated, polymer-based cassette for loop-mediated isothermal amplification (LAMP) of target nucleic acids was designed, fabricated, and tested. The LAMP chamber was equipped with single-use, thermally actuated valves made with a composite consisting of a mixture of PDMS and expandable microspheres. The effect of the composite composition on its expansion was investigated, and the valve’s performance was evaluated. In its closed state, the valve can hold pressures as high as 200 kPa without any significant leakage. Both the LAMP chamber and the valves were actuated with thin film heaters. The utility of the cassette was demonstrated by carrying out LAMP of Escherichia coli DNA target and reverse transcribed loop meditated isothermal amplification (RT-LAMP) of RNA targets. The amplicons were detected in real time with a portable, compact detector. The system was capable of detecting as few as 10 target molecules per sample in well under 1 h. The portable, integrated cassette system described here is particularly suited for applications at the point of care and in resource-poor countries, where funds and trained personnel are in short supply. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10404-011-0788-3) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-7088409
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-70884092020-03-23 A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves Liu, Changchun Mauk, Michael G. Bau, Haim H. Microfluid Nanofluidics Research Paper An inexpensive, disposable, integrated, polymer-based cassette for loop-mediated isothermal amplification (LAMP) of target nucleic acids was designed, fabricated, and tested. The LAMP chamber was equipped with single-use, thermally actuated valves made with a composite consisting of a mixture of PDMS and expandable microspheres. The effect of the composite composition on its expansion was investigated, and the valve’s performance was evaluated. In its closed state, the valve can hold pressures as high as 200 kPa without any significant leakage. Both the LAMP chamber and the valves were actuated with thin film heaters. The utility of the cassette was demonstrated by carrying out LAMP of Escherichia coli DNA target and reverse transcribed loop meditated isothermal amplification (RT-LAMP) of RNA targets. The amplicons were detected in real time with a portable, compact detector. The system was capable of detecting as few as 10 target molecules per sample in well under 1 h. The portable, integrated cassette system described here is particularly suited for applications at the point of care and in resource-poor countries, where funds and trained personnel are in short supply. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10404-011-0788-3) contains supplementary material, which is available to authorized users. Springer-Verlag 2011-03-18 2011 /pmc/articles/PMC7088409/ /pubmed/32214952 http://dx.doi.org/10.1007/s10404-011-0788-3 Text en © Springer-Verlag 2011 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Research Paper
Liu, Changchun
Mauk, Michael G.
Bau, Haim H.
A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves
title A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves
title_full A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves
title_fullStr A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves
title_full_unstemmed A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves
title_short A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves
title_sort disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7088409/
https://www.ncbi.nlm.nih.gov/pubmed/32214952
http://dx.doi.org/10.1007/s10404-011-0788-3
work_keys_str_mv AT liuchangchun adisposableintegratedloopmediatedisothermalamplificationcassettewiththermallyactuatedvalves
AT maukmichaelg adisposableintegratedloopmediatedisothermalamplificationcassettewiththermallyactuatedvalves
AT bauhaimh adisposableintegratedloopmediatedisothermalamplificationcassettewiththermallyactuatedvalves
AT liuchangchun disposableintegratedloopmediatedisothermalamplificationcassettewiththermallyactuatedvalves
AT maukmichaelg disposableintegratedloopmediatedisothermalamplificationcassettewiththermallyactuatedvalves
AT bauhaimh disposableintegratedloopmediatedisothermalamplificationcassettewiththermallyactuatedvalves