Cargando…

Recombinase polymerase amplification–nucleic acid lateral flow immunoassays for Newcastle disease virus and infectious bronchitis virus detection

Newcastle disease virus (NDV) and infectious bronchitis virus (IBV) are two poultry pathogens affecting the respiratory tract of chickens, and cause major economic losses in the industry. Rapid detection of these viruses is crucial to inform implementation of appropriate control measures. The object...

Descripción completa

Detalles Bibliográficos
Autores principales: El-Tholoth, Mohamed, Branavan, Manoharanehru, Naveenathayalan, Angel, Balachandran, Wamadeva
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7089497/
https://www.ncbi.nlm.nih.gov/pubmed/31549369
http://dx.doi.org/10.1007/s11033-019-05085-y
_version_ 1783509749416853504
author El-Tholoth, Mohamed
Branavan, Manoharanehru
Naveenathayalan, Angel
Balachandran, Wamadeva
author_facet El-Tholoth, Mohamed
Branavan, Manoharanehru
Naveenathayalan, Angel
Balachandran, Wamadeva
author_sort El-Tholoth, Mohamed
collection PubMed
description Newcastle disease virus (NDV) and infectious bronchitis virus (IBV) are two poultry pathogens affecting the respiratory tract of chickens, and cause major economic losses in the industry. Rapid detection of these viruses is crucial to inform implementation of appropriate control measures. The objective of our study is developing a simple, rapid and field applicable recombinase polymerase amplification (RPA)–nucleic acid lateral flow (NALF) immunoassay for detection of NDV and IBV. Isothermal amplification of the matrix protein (M) gene of NDV and the nucleoprotein (N) gene of IBV was implemented via recombinase polymerase amplification at 38 °C for 40 min and 20 min, respectively using modified labeled primers. NALF device used in this study utilizes antibodies for detection of labeled RPA amplicons. The results revealed that RPA-NALF immunoassays can detect both viruses after 40 min at 38 °C and only NDV after 20 min. The limit of detection (LOD) was 10 genomic copies/RPA reaction. The assays results on clinical samples collected from diseased chicken farms demonstrated a good performance in comparison with quantitative real time reverse transcription polymerase chain reaction (qRT-PCR). The assays established in this study can facilitate rapid, on-site molecular diagnosis of suspected cases of ND and IB viral infections as the results can be detected by the naked eye without the need for measuring fluorescence. Furthermore, the NALF device could be adapted to detect other infectious agents.
format Online
Article
Text
id pubmed-7089497
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-70894972020-03-23 Recombinase polymerase amplification–nucleic acid lateral flow immunoassays for Newcastle disease virus and infectious bronchitis virus detection El-Tholoth, Mohamed Branavan, Manoharanehru Naveenathayalan, Angel Balachandran, Wamadeva Mol Biol Rep Original Article Newcastle disease virus (NDV) and infectious bronchitis virus (IBV) are two poultry pathogens affecting the respiratory tract of chickens, and cause major economic losses in the industry. Rapid detection of these viruses is crucial to inform implementation of appropriate control measures. The objective of our study is developing a simple, rapid and field applicable recombinase polymerase amplification (RPA)–nucleic acid lateral flow (NALF) immunoassay for detection of NDV and IBV. Isothermal amplification of the matrix protein (M) gene of NDV and the nucleoprotein (N) gene of IBV was implemented via recombinase polymerase amplification at 38 °C for 40 min and 20 min, respectively using modified labeled primers. NALF device used in this study utilizes antibodies for detection of labeled RPA amplicons. The results revealed that RPA-NALF immunoassays can detect both viruses after 40 min at 38 °C and only NDV after 20 min. The limit of detection (LOD) was 10 genomic copies/RPA reaction. The assays results on clinical samples collected from diseased chicken farms demonstrated a good performance in comparison with quantitative real time reverse transcription polymerase chain reaction (qRT-PCR). The assays established in this study can facilitate rapid, on-site molecular diagnosis of suspected cases of ND and IB viral infections as the results can be detected by the naked eye without the need for measuring fluorescence. Furthermore, the NALF device could be adapted to detect other infectious agents. Springer Netherlands 2019-09-23 2019 /pmc/articles/PMC7089497/ /pubmed/31549369 http://dx.doi.org/10.1007/s11033-019-05085-y Text en © Springer Nature B.V. 2019 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Original Article
El-Tholoth, Mohamed
Branavan, Manoharanehru
Naveenathayalan, Angel
Balachandran, Wamadeva
Recombinase polymerase amplification–nucleic acid lateral flow immunoassays for Newcastle disease virus and infectious bronchitis virus detection
title Recombinase polymerase amplification–nucleic acid lateral flow immunoassays for Newcastle disease virus and infectious bronchitis virus detection
title_full Recombinase polymerase amplification–nucleic acid lateral flow immunoassays for Newcastle disease virus and infectious bronchitis virus detection
title_fullStr Recombinase polymerase amplification–nucleic acid lateral flow immunoassays for Newcastle disease virus and infectious bronchitis virus detection
title_full_unstemmed Recombinase polymerase amplification–nucleic acid lateral flow immunoassays for Newcastle disease virus and infectious bronchitis virus detection
title_short Recombinase polymerase amplification–nucleic acid lateral flow immunoassays for Newcastle disease virus and infectious bronchitis virus detection
title_sort recombinase polymerase amplification–nucleic acid lateral flow immunoassays for newcastle disease virus and infectious bronchitis virus detection
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7089497/
https://www.ncbi.nlm.nih.gov/pubmed/31549369
http://dx.doi.org/10.1007/s11033-019-05085-y
work_keys_str_mv AT eltholothmohamed recombinasepolymeraseamplificationnucleicacidlateralflowimmunoassaysfornewcastlediseasevirusandinfectiousbronchitisvirusdetection
AT branavanmanoharanehru recombinasepolymeraseamplificationnucleicacidlateralflowimmunoassaysfornewcastlediseasevirusandinfectiousbronchitisvirusdetection
AT naveenathayalanangel recombinasepolymeraseamplificationnucleicacidlateralflowimmunoassaysfornewcastlediseasevirusandinfectiousbronchitisvirusdetection
AT balachandranwamadeva recombinasepolymeraseamplificationnucleicacidlateralflowimmunoassaysfornewcastlediseasevirusandinfectiousbronchitisvirusdetection