Cargando…
Prospective evaluation of 25-gauge Franseen needles for endoscopic ultrasound-guided fine-needle biopsy of solid pancreatic masses
Background and study aims The ideal puncture needle for endoscopic ultrasound (EUS)-guided sampling is maneuverable and easy to puncture with, and can obtain sufficient material in almost one pass. The novel 25-gauge Franseen needle may provide a good balance between maneuverability and sample yiel...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
© Georg Thieme Verlag KG
2020
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7089784/ https://www.ncbi.nlm.nih.gov/pubmed/32258381 http://dx.doi.org/10.1055/a-1119-6673 |
_version_ | 1783509800661811200 |
---|---|
author | Inoue, Tadahisa Tsuzuki, Toyonori Takahara, Taishi Ibusuki, Mayu Kitano, Rena Kobayashi, Yuji Ohashi, Tomohiko Nakade, Yukiomi Sumida, Yoshio Ito, Kiyoaki Yoneda, Masashi |
author_facet | Inoue, Tadahisa Tsuzuki, Toyonori Takahara, Taishi Ibusuki, Mayu Kitano, Rena Kobayashi, Yuji Ohashi, Tomohiko Nakade, Yukiomi Sumida, Yoshio Ito, Kiyoaki Yoneda, Masashi |
author_sort | Inoue, Tadahisa |
collection | PubMed |
description | Background and study aims The ideal puncture needle for endoscopic ultrasound (EUS)-guided sampling is maneuverable and easy to puncture with, and can obtain sufficient material in almost one pass. The novel 25-gauge Franseen needle may provide a good balance between maneuverability and sample yield. Patients and methods Between July 2017 and December 2018, 116 patients with solid pancreatic masses were prospectively enrolled and investigated. We evaluated the diagnostic yield associated with using the 25-gauge Franseen needle for EUS-guided sampling of pancreatic masses. Results The technical success rate was 100 % (116/116). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for malignancy were 98 % (105/107), 100 % (9/9), 100 % (105/105), 82 % (9/11), and 98 % (114/116), respectively. Cumulative sensitivities for malignancy were 87 % (93/107) on pass 1, 97 % (104/107) on pass 2, and 98 % (105/107) on pass 3, respectively, with no increase in sensitivity after 4 or more. An adequate specimen for histological assessment was obtained in 79 % (92/116) of cases. Multivariate logistic analyses showed that lesion size smaller than 13 mm was a risk factor for failure of obtaining an adequate specimen for histological assessment ( P = 0.010) Conclusions The novel 25-gauge Franseen needle showed excellent diagnostic yield for solid pancreatic masses. However, its ability to obtain an adequate specimen for histological assessment may still be insufficient, especially when dealing with small lesions. |
format | Online Article Text |
id | pubmed-7089784 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | © Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-70897842020-04-01 Prospective evaluation of 25-gauge Franseen needles for endoscopic ultrasound-guided fine-needle biopsy of solid pancreatic masses Inoue, Tadahisa Tsuzuki, Toyonori Takahara, Taishi Ibusuki, Mayu Kitano, Rena Kobayashi, Yuji Ohashi, Tomohiko Nakade, Yukiomi Sumida, Yoshio Ito, Kiyoaki Yoneda, Masashi Endosc Int Open Background and study aims The ideal puncture needle for endoscopic ultrasound (EUS)-guided sampling is maneuverable and easy to puncture with, and can obtain sufficient material in almost one pass. The novel 25-gauge Franseen needle may provide a good balance between maneuverability and sample yield. Patients and methods Between July 2017 and December 2018, 116 patients with solid pancreatic masses were prospectively enrolled and investigated. We evaluated the diagnostic yield associated with using the 25-gauge Franseen needle for EUS-guided sampling of pancreatic masses. Results The technical success rate was 100 % (116/116). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for malignancy were 98 % (105/107), 100 % (9/9), 100 % (105/105), 82 % (9/11), and 98 % (114/116), respectively. Cumulative sensitivities for malignancy were 87 % (93/107) on pass 1, 97 % (104/107) on pass 2, and 98 % (105/107) on pass 3, respectively, with no increase in sensitivity after 4 or more. An adequate specimen for histological assessment was obtained in 79 % (92/116) of cases. Multivariate logistic analyses showed that lesion size smaller than 13 mm was a risk factor for failure of obtaining an adequate specimen for histological assessment ( P = 0.010) Conclusions The novel 25-gauge Franseen needle showed excellent diagnostic yield for solid pancreatic masses. However, its ability to obtain an adequate specimen for histological assessment may still be insufficient, especially when dealing with small lesions. © Georg Thieme Verlag KG 2020-04 2020-03-23 /pmc/articles/PMC7089784/ /pubmed/32258381 http://dx.doi.org/10.1055/a-1119-6673 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited. |
spellingShingle | Inoue, Tadahisa Tsuzuki, Toyonori Takahara, Taishi Ibusuki, Mayu Kitano, Rena Kobayashi, Yuji Ohashi, Tomohiko Nakade, Yukiomi Sumida, Yoshio Ito, Kiyoaki Yoneda, Masashi Prospective evaluation of 25-gauge Franseen needles for endoscopic ultrasound-guided fine-needle biopsy of solid pancreatic masses |
title | Prospective evaluation of 25-gauge Franseen needles for endoscopic ultrasound-guided fine-needle biopsy of solid pancreatic masses |
title_full | Prospective evaluation of 25-gauge Franseen needles for endoscopic ultrasound-guided fine-needle biopsy of solid pancreatic masses |
title_fullStr | Prospective evaluation of 25-gauge Franseen needles for endoscopic ultrasound-guided fine-needle biopsy of solid pancreatic masses |
title_full_unstemmed | Prospective evaluation of 25-gauge Franseen needles for endoscopic ultrasound-guided fine-needle biopsy of solid pancreatic masses |
title_short | Prospective evaluation of 25-gauge Franseen needles for endoscopic ultrasound-guided fine-needle biopsy of solid pancreatic masses |
title_sort | prospective evaluation of 25-gauge franseen needles for endoscopic ultrasound-guided fine-needle biopsy of solid pancreatic masses |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7089784/ https://www.ncbi.nlm.nih.gov/pubmed/32258381 http://dx.doi.org/10.1055/a-1119-6673 |
work_keys_str_mv | AT inouetadahisa prospectiveevaluationof25gaugefranseenneedlesforendoscopicultrasoundguidedfineneedlebiopsyofsolidpancreaticmasses AT tsuzukitoyonori prospectiveevaluationof25gaugefranseenneedlesforendoscopicultrasoundguidedfineneedlebiopsyofsolidpancreaticmasses AT takaharataishi prospectiveevaluationof25gaugefranseenneedlesforendoscopicultrasoundguidedfineneedlebiopsyofsolidpancreaticmasses AT ibusukimayu prospectiveevaluationof25gaugefranseenneedlesforendoscopicultrasoundguidedfineneedlebiopsyofsolidpancreaticmasses AT kitanorena prospectiveevaluationof25gaugefranseenneedlesforendoscopicultrasoundguidedfineneedlebiopsyofsolidpancreaticmasses AT kobayashiyuji prospectiveevaluationof25gaugefranseenneedlesforendoscopicultrasoundguidedfineneedlebiopsyofsolidpancreaticmasses AT ohashitomohiko prospectiveevaluationof25gaugefranseenneedlesforendoscopicultrasoundguidedfineneedlebiopsyofsolidpancreaticmasses AT nakadeyukiomi prospectiveevaluationof25gaugefranseenneedlesforendoscopicultrasoundguidedfineneedlebiopsyofsolidpancreaticmasses AT sumidayoshio prospectiveevaluationof25gaugefranseenneedlesforendoscopicultrasoundguidedfineneedlebiopsyofsolidpancreaticmasses AT itokiyoaki prospectiveevaluationof25gaugefranseenneedlesforendoscopicultrasoundguidedfineneedlebiopsyofsolidpancreaticmasses AT yonedamasashi prospectiveevaluationof25gaugefranseenneedlesforendoscopicultrasoundguidedfineneedlebiopsyofsolidpancreaticmasses |