Cargando…

Comparison of the Efficacy and Safety of Insulin Detemir Administered Once Daily According to Two Titration Algorithms (3-0-3 and 2-4-6-8) in Patients with Type 2 Diabetes Mellitus

BACKGROUND: This study was conducted to compare glycaemic control with insulin detemir administered according to two titration algorithms (3-0-3 and 2-4-6-8) after 20 weeks of treatment in subjects with type 2 diabetes mellitus inadequately controlled on metformin. METHODS: This was a 20-week, rando...

Descripción completa

Detalles Bibliográficos
Autores principales: Yu, Hea Min, Park, Kang Seo, Hong, Jun Hwa, Park, Keun Yong, Lee, Jong Min, Ku, Bon Jeong, Kim, Yeo Joo, Oh, Tae Kun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Endocrine Society 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7090293/
https://www.ncbi.nlm.nih.gov/pubmed/32207274
http://dx.doi.org/10.3803/EnM.2020.35.1.142
_version_ 1783509902536212480
author Yu, Hea Min
Park, Kang Seo
Hong, Jun Hwa
Park, Keun Yong
Lee, Jong Min
Ku, Bon Jeong
Kim, Yeo Joo
Oh, Tae Kun
author_facet Yu, Hea Min
Park, Kang Seo
Hong, Jun Hwa
Park, Keun Yong
Lee, Jong Min
Ku, Bon Jeong
Kim, Yeo Joo
Oh, Tae Kun
author_sort Yu, Hea Min
collection PubMed
description BACKGROUND: This study was conducted to compare glycaemic control with insulin detemir administered according to two titration algorithms (3-0-3 and 2-4-6-8) after 20 weeks of treatment in subjects with type 2 diabetes mellitus inadequately controlled on metformin. METHODS: This was a 20-week, randomised, multicentre, open-labelled, treat-to-target trial. Forty-six patients were randomised in a 1:1 manner to either the 3-0-3 (G3, n=23) or 2-4-6-8 (G2, n=23) algorithm. The primary endpoint was change of haemoglobin A1c (HbA1c), and the secondary safety endpoint included hypoglycaemic events. RESULTS: After 20 weeks, HbA1c decreased similarly in the G3 and G2 groups, with a mean change of −0.9% from baseline. The mean change in fasting plasma glucose was numerically similar in both groups. The hypoglycaemia event rate per 100-patient-years of exposure (r) in the G2 group (r=1,427) was higher than that in the G3 group (r=807). CONCLUSION: Both treatment groups had numerically similar HbA1c reductions. A trend towards fewer hypoglycaemia episodes after dose stabilisation was seen with the simpler G3. Clinically, this may be an important observation, as a simpler titration algorithm may support self-management and maintenance of insulin therapy.
format Online
Article
Text
id pubmed-7090293
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Korean Endocrine Society
record_format MEDLINE/PubMed
spelling pubmed-70902932020-04-01 Comparison of the Efficacy and Safety of Insulin Detemir Administered Once Daily According to Two Titration Algorithms (3-0-3 and 2-4-6-8) in Patients with Type 2 Diabetes Mellitus Yu, Hea Min Park, Kang Seo Hong, Jun Hwa Park, Keun Yong Lee, Jong Min Ku, Bon Jeong Kim, Yeo Joo Oh, Tae Kun Endocrinol Metab (Seoul) Original Article BACKGROUND: This study was conducted to compare glycaemic control with insulin detemir administered according to two titration algorithms (3-0-3 and 2-4-6-8) after 20 weeks of treatment in subjects with type 2 diabetes mellitus inadequately controlled on metformin. METHODS: This was a 20-week, randomised, multicentre, open-labelled, treat-to-target trial. Forty-six patients were randomised in a 1:1 manner to either the 3-0-3 (G3, n=23) or 2-4-6-8 (G2, n=23) algorithm. The primary endpoint was change of haemoglobin A1c (HbA1c), and the secondary safety endpoint included hypoglycaemic events. RESULTS: After 20 weeks, HbA1c decreased similarly in the G3 and G2 groups, with a mean change of −0.9% from baseline. The mean change in fasting plasma glucose was numerically similar in both groups. The hypoglycaemia event rate per 100-patient-years of exposure (r) in the G2 group (r=1,427) was higher than that in the G3 group (r=807). CONCLUSION: Both treatment groups had numerically similar HbA1c reductions. A trend towards fewer hypoglycaemia episodes after dose stabilisation was seen with the simpler G3. Clinically, this may be an important observation, as a simpler titration algorithm may support self-management and maintenance of insulin therapy. Korean Endocrine Society 2020-03 2020-03-19 /pmc/articles/PMC7090293/ /pubmed/32207274 http://dx.doi.org/10.3803/EnM.2020.35.1.142 Text en Copyright © 2020 Korean Endocrine Society http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yu, Hea Min
Park, Kang Seo
Hong, Jun Hwa
Park, Keun Yong
Lee, Jong Min
Ku, Bon Jeong
Kim, Yeo Joo
Oh, Tae Kun
Comparison of the Efficacy and Safety of Insulin Detemir Administered Once Daily According to Two Titration Algorithms (3-0-3 and 2-4-6-8) in Patients with Type 2 Diabetes Mellitus
title Comparison of the Efficacy and Safety of Insulin Detemir Administered Once Daily According to Two Titration Algorithms (3-0-3 and 2-4-6-8) in Patients with Type 2 Diabetes Mellitus
title_full Comparison of the Efficacy and Safety of Insulin Detemir Administered Once Daily According to Two Titration Algorithms (3-0-3 and 2-4-6-8) in Patients with Type 2 Diabetes Mellitus
title_fullStr Comparison of the Efficacy and Safety of Insulin Detemir Administered Once Daily According to Two Titration Algorithms (3-0-3 and 2-4-6-8) in Patients with Type 2 Diabetes Mellitus
title_full_unstemmed Comparison of the Efficacy and Safety of Insulin Detemir Administered Once Daily According to Two Titration Algorithms (3-0-3 and 2-4-6-8) in Patients with Type 2 Diabetes Mellitus
title_short Comparison of the Efficacy and Safety of Insulin Detemir Administered Once Daily According to Two Titration Algorithms (3-0-3 and 2-4-6-8) in Patients with Type 2 Diabetes Mellitus
title_sort comparison of the efficacy and safety of insulin detemir administered once daily according to two titration algorithms (3-0-3 and 2-4-6-8) in patients with type 2 diabetes mellitus
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7090293/
https://www.ncbi.nlm.nih.gov/pubmed/32207274
http://dx.doi.org/10.3803/EnM.2020.35.1.142
work_keys_str_mv AT yuheamin comparisonoftheefficacyandsafetyofinsulindetemiradministeredoncedailyaccordingtotwotitrationalgorithms303and2468inpatientswithtype2diabetesmellitus
AT parkkangseo comparisonoftheefficacyandsafetyofinsulindetemiradministeredoncedailyaccordingtotwotitrationalgorithms303and2468inpatientswithtype2diabetesmellitus
AT hongjunhwa comparisonoftheefficacyandsafetyofinsulindetemiradministeredoncedailyaccordingtotwotitrationalgorithms303and2468inpatientswithtype2diabetesmellitus
AT parkkeunyong comparisonoftheefficacyandsafetyofinsulindetemiradministeredoncedailyaccordingtotwotitrationalgorithms303and2468inpatientswithtype2diabetesmellitus
AT leejongmin comparisonoftheefficacyandsafetyofinsulindetemiradministeredoncedailyaccordingtotwotitrationalgorithms303and2468inpatientswithtype2diabetesmellitus
AT kubonjeong comparisonoftheefficacyandsafetyofinsulindetemiradministeredoncedailyaccordingtotwotitrationalgorithms303and2468inpatientswithtype2diabetesmellitus
AT kimyeojoo comparisonoftheefficacyandsafetyofinsulindetemiradministeredoncedailyaccordingtotwotitrationalgorithms303and2468inpatientswithtype2diabetesmellitus
AT ohtaekun comparisonoftheefficacyandsafetyofinsulindetemiradministeredoncedailyaccordingtotwotitrationalgorithms303and2468inpatientswithtype2diabetesmellitus