Cargando…
Spondyloarthritis Research Consortium of Canada sacroiliac joint inflammation and structural scores: change score reliability and recalibration utility in children
BACKGROUND: The SPARCC sacroiliac joint inflammation (SIS) and structural (SSS) scores are reliable measures to quantify abnormalities in the pediatric sacroiliac joint. We aimed to evaluate the utility of online calibration modules for the SIS and SSS and the reliability of their component change s...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7092669/ https://www.ncbi.nlm.nih.gov/pubmed/32209120 http://dx.doi.org/10.1186/s13075-020-02157-4 |
_version_ | 1783510149883756544 |
---|---|
author | Weiss, Pamela F. Maksymowych, Walter P. Xiao, Rui Biko, David M. Francavilla, Michael L. Lambert, Robert G. Jaremko, Jacob L. Heshin-Bekenstein, Merav Brandon, Timothy G. Chauvin, Nancy A. |
author_facet | Weiss, Pamela F. Maksymowych, Walter P. Xiao, Rui Biko, David M. Francavilla, Michael L. Lambert, Robert G. Jaremko, Jacob L. Heshin-Bekenstein, Merav Brandon, Timothy G. Chauvin, Nancy A. |
author_sort | Weiss, Pamela F. |
collection | PubMed |
description | BACKGROUND: The SPARCC sacroiliac joint inflammation (SIS) and structural (SSS) scores are reliable measures to quantify abnormalities in the pediatric sacroiliac joint. We aimed to evaluate the utility of online calibration modules for the SIS and SSS and the reliability of their component change scores. METHODS: Change score reliability of 6 raters was assessed by overall and pairwise intraclass correlation coefficients (ICCs) before and after the use of real-time iterative calibration (RETIC) modules for both the SIS and SSS comprised of 20 adult cases. Acceptable ICC for change scores was > 0.7 for SIS and > 0.5 for all SSS components. Sensitivity to change was assessed by the standardized response mean (SRM). RESULTS: In scoring exercise 1, the SIS had acceptable reliability with a change score ICC of 0.80 and sclerosis was the only SSS lesion that met the acceptability threshold with a change score ICC of 0.52. After RETIC calibration, the SIS overall (ICC = 0.83) and mean pairwise (ICC = 0.83) change scores remained reliable with a large SRM (0.90). All SSS components except sclerosis met the overall and mean pairwise change score ICC acceptability thresholds—backfill: overall = 0.54, mean pairwise = 0.50; fat metaplasia: overall = 0.65, mean pairwise = 0.57; erosion: overall = 0.60, mean pairwise = 0.58; and ankylosis: overall = 0.96, mean pairwise = 0.96. The SSS RETIC module augmented the number of SSS components surpassing the acceptability threshold from 1 to 4. Sensitivity to change, as measured by the SRM, was large for erosion (0.96), moderate for backfill (0.55) and sclerosis (0.70), and small for fat metaplasia (0.36) and ankylosis (0.28). CONCLUSION: RETIC modules improved the overall reliability of SPARCC SIS and SSS change scores for previously calibrated raters. SIS recalibration was not as helpful to the most experienced raters who achieved high levels of agreement before recalibration. The SPARCC SIS and all SSS components except sclerosis are reliable measures to quantify change over time in children. A pediatric-specific RETIC tool should be developed to enhance the calibration of readers. |
format | Online Article Text |
id | pubmed-7092669 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-70926692020-03-27 Spondyloarthritis Research Consortium of Canada sacroiliac joint inflammation and structural scores: change score reliability and recalibration utility in children Weiss, Pamela F. Maksymowych, Walter P. Xiao, Rui Biko, David M. Francavilla, Michael L. Lambert, Robert G. Jaremko, Jacob L. Heshin-Bekenstein, Merav Brandon, Timothy G. Chauvin, Nancy A. Arthritis Res Ther Research Article BACKGROUND: The SPARCC sacroiliac joint inflammation (SIS) and structural (SSS) scores are reliable measures to quantify abnormalities in the pediatric sacroiliac joint. We aimed to evaluate the utility of online calibration modules for the SIS and SSS and the reliability of their component change scores. METHODS: Change score reliability of 6 raters was assessed by overall and pairwise intraclass correlation coefficients (ICCs) before and after the use of real-time iterative calibration (RETIC) modules for both the SIS and SSS comprised of 20 adult cases. Acceptable ICC for change scores was > 0.7 for SIS and > 0.5 for all SSS components. Sensitivity to change was assessed by the standardized response mean (SRM). RESULTS: In scoring exercise 1, the SIS had acceptable reliability with a change score ICC of 0.80 and sclerosis was the only SSS lesion that met the acceptability threshold with a change score ICC of 0.52. After RETIC calibration, the SIS overall (ICC = 0.83) and mean pairwise (ICC = 0.83) change scores remained reliable with a large SRM (0.90). All SSS components except sclerosis met the overall and mean pairwise change score ICC acceptability thresholds—backfill: overall = 0.54, mean pairwise = 0.50; fat metaplasia: overall = 0.65, mean pairwise = 0.57; erosion: overall = 0.60, mean pairwise = 0.58; and ankylosis: overall = 0.96, mean pairwise = 0.96. The SSS RETIC module augmented the number of SSS components surpassing the acceptability threshold from 1 to 4. Sensitivity to change, as measured by the SRM, was large for erosion (0.96), moderate for backfill (0.55) and sclerosis (0.70), and small for fat metaplasia (0.36) and ankylosis (0.28). CONCLUSION: RETIC modules improved the overall reliability of SPARCC SIS and SSS change scores for previously calibrated raters. SIS recalibration was not as helpful to the most experienced raters who achieved high levels of agreement before recalibration. The SPARCC SIS and all SSS components except sclerosis are reliable measures to quantify change over time in children. A pediatric-specific RETIC tool should be developed to enhance the calibration of readers. BioMed Central 2020-03-24 2020 /pmc/articles/PMC7092669/ /pubmed/32209120 http://dx.doi.org/10.1186/s13075-020-02157-4 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Weiss, Pamela F. Maksymowych, Walter P. Xiao, Rui Biko, David M. Francavilla, Michael L. Lambert, Robert G. Jaremko, Jacob L. Heshin-Bekenstein, Merav Brandon, Timothy G. Chauvin, Nancy A. Spondyloarthritis Research Consortium of Canada sacroiliac joint inflammation and structural scores: change score reliability and recalibration utility in children |
title | Spondyloarthritis Research Consortium of Canada sacroiliac joint inflammation and structural scores: change score reliability and recalibration utility in children |
title_full | Spondyloarthritis Research Consortium of Canada sacroiliac joint inflammation and structural scores: change score reliability and recalibration utility in children |
title_fullStr | Spondyloarthritis Research Consortium of Canada sacroiliac joint inflammation and structural scores: change score reliability and recalibration utility in children |
title_full_unstemmed | Spondyloarthritis Research Consortium of Canada sacroiliac joint inflammation and structural scores: change score reliability and recalibration utility in children |
title_short | Spondyloarthritis Research Consortium of Canada sacroiliac joint inflammation and structural scores: change score reliability and recalibration utility in children |
title_sort | spondyloarthritis research consortium of canada sacroiliac joint inflammation and structural scores: change score reliability and recalibration utility in children |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7092669/ https://www.ncbi.nlm.nih.gov/pubmed/32209120 http://dx.doi.org/10.1186/s13075-020-02157-4 |
work_keys_str_mv | AT weisspamelaf spondyloarthritisresearchconsortiumofcanadasacroiliacjointinflammationandstructuralscoreschangescorereliabilityandrecalibrationutilityinchildren AT maksymowychwalterp spondyloarthritisresearchconsortiumofcanadasacroiliacjointinflammationandstructuralscoreschangescorereliabilityandrecalibrationutilityinchildren AT xiaorui spondyloarthritisresearchconsortiumofcanadasacroiliacjointinflammationandstructuralscoreschangescorereliabilityandrecalibrationutilityinchildren AT bikodavidm spondyloarthritisresearchconsortiumofcanadasacroiliacjointinflammationandstructuralscoreschangescorereliabilityandrecalibrationutilityinchildren AT francavillamichaell spondyloarthritisresearchconsortiumofcanadasacroiliacjointinflammationandstructuralscoreschangescorereliabilityandrecalibrationutilityinchildren AT lambertrobertg spondyloarthritisresearchconsortiumofcanadasacroiliacjointinflammationandstructuralscoreschangescorereliabilityandrecalibrationutilityinchildren AT jaremkojacobl spondyloarthritisresearchconsortiumofcanadasacroiliacjointinflammationandstructuralscoreschangescorereliabilityandrecalibrationutilityinchildren AT heshinbekensteinmerav spondyloarthritisresearchconsortiumofcanadasacroiliacjointinflammationandstructuralscoreschangescorereliabilityandrecalibrationutilityinchildren AT brandontimothyg spondyloarthritisresearchconsortiumofcanadasacroiliacjointinflammationandstructuralscoreschangescorereliabilityandrecalibrationutilityinchildren AT chauvinnancya spondyloarthritisresearchconsortiumofcanadasacroiliacjointinflammationandstructuralscoreschangescorereliabilityandrecalibrationutilityinchildren |