Cargando…

Chronic Kidney Disease in Patients Undergoing Cardiac Device Placement: Results of a Retrospective Study

BACKGROUND: Cardiovascular issues (especially arrhythmia and sudden cardiac death) are one of the most common causes of mortality in patients with chronic kidney disease (CKD). To minimize cardiac mortality, these patients frequently require various cardiac devices, such as pacemakers, loop recorder...

Descripción completa

Detalles Bibliográficos
Autores principales: Hossain, Mohammad A., Ajam, Firas, Mahida, Hetavi, Alrefaee, Anas, Patel, Swapnil, Agarwal, Khushboo, Alidoost, Marjan, Dahab, Shereen, Quinlan, Amy, Orange, Michael, Mushtaq, Arman, Asif, Arif
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elmer Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7092765/
https://www.ncbi.nlm.nih.gov/pubmed/32231754
http://dx.doi.org/10.14740/jocmr4075
_version_ 1783510165213937664
author Hossain, Mohammad A.
Ajam, Firas
Mahida, Hetavi
Alrefaee, Anas
Patel, Swapnil
Agarwal, Khushboo
Alidoost, Marjan
Dahab, Shereen
Quinlan, Amy
Orange, Michael
Mushtaq, Arman
Asif, Arif
author_facet Hossain, Mohammad A.
Ajam, Firas
Mahida, Hetavi
Alrefaee, Anas
Patel, Swapnil
Agarwal, Khushboo
Alidoost, Marjan
Dahab, Shereen
Quinlan, Amy
Orange, Michael
Mushtaq, Arman
Asif, Arif
author_sort Hossain, Mohammad A.
collection PubMed
description BACKGROUND: Cardiovascular issues (especially arrhythmia and sudden cardiac death) are one of the most common causes of mortality in patients with chronic kidney disease (CKD). To minimize cardiac mortality, these patients frequently require various cardiac devices, such as pacemakers, loop recorders, and defibrillators which can compromise their vascular access. In this study, we aim to determine the prevalence of CKD in patients undergoing cardiac device placement and their progression of CKD. METHODS: Institutional review board approval was obtained for this study. A total of 688 patients undergoing cardiac device placement were included in this study over a 3-year period at Jersey Shore University Medical Center. Demographic characteristics, comorbidities, base-line renal functions during the procedure, types of cardiac devices, sites of vascular access and follow-up renal function when available were assessed retrospectively. Patients were categorized into CKD stages 1 - 5 based on the National Kidney Foundation-Kidney Disease Outcomes Quality Initiative (NKF-KDOQI) guidelines. The patients who were already on hemodialysis were excluded in this study. RESULTS: The average age of the patient were 73.9 years with male predominance (60%). A total of 227 patients (33%) had estimated glomerular filtration rate (eGFR) < 60 mL/min consistent with the evidence of advanced-stage CKD (stages 3 - 5) at the time of cardiac device placement. The most common types of device placements were new insertion/replacement of atrial and ventricular leads (39.5%), loop recorder implantation (21.1%) and generator changes on an already implanted device (11%). Only 4% (28/688) had a leadless cardiac device placement. The most common access sites were subclavian (47.1%), axillary (32.3%) and femoral (12.2%). CONCLUSIONS: The present study demonstrated that nearly one-third of the patient undergoing cardiac device placement had an advanced degree of renal failure. Because CKD is a progressive disease, many of these patients might require renal replacement therapy in the future. Transvenous devices is not a good choice in this group of patients as they will ultimately require an arteriovenous fistula. Subcutaneous leadless cardiac device insertion might be a better option in patients with advanced CKD.
format Online
Article
Text
id pubmed-7092765
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elmer Press
record_format MEDLINE/PubMed
spelling pubmed-70927652020-03-30 Chronic Kidney Disease in Patients Undergoing Cardiac Device Placement: Results of a Retrospective Study Hossain, Mohammad A. Ajam, Firas Mahida, Hetavi Alrefaee, Anas Patel, Swapnil Agarwal, Khushboo Alidoost, Marjan Dahab, Shereen Quinlan, Amy Orange, Michael Mushtaq, Arman Asif, Arif J Clin Med Res Original Article BACKGROUND: Cardiovascular issues (especially arrhythmia and sudden cardiac death) are one of the most common causes of mortality in patients with chronic kidney disease (CKD). To minimize cardiac mortality, these patients frequently require various cardiac devices, such as pacemakers, loop recorders, and defibrillators which can compromise their vascular access. In this study, we aim to determine the prevalence of CKD in patients undergoing cardiac device placement and their progression of CKD. METHODS: Institutional review board approval was obtained for this study. A total of 688 patients undergoing cardiac device placement were included in this study over a 3-year period at Jersey Shore University Medical Center. Demographic characteristics, comorbidities, base-line renal functions during the procedure, types of cardiac devices, sites of vascular access and follow-up renal function when available were assessed retrospectively. Patients were categorized into CKD stages 1 - 5 based on the National Kidney Foundation-Kidney Disease Outcomes Quality Initiative (NKF-KDOQI) guidelines. The patients who were already on hemodialysis were excluded in this study. RESULTS: The average age of the patient were 73.9 years with male predominance (60%). A total of 227 patients (33%) had estimated glomerular filtration rate (eGFR) < 60 mL/min consistent with the evidence of advanced-stage CKD (stages 3 - 5) at the time of cardiac device placement. The most common types of device placements were new insertion/replacement of atrial and ventricular leads (39.5%), loop recorder implantation (21.1%) and generator changes on an already implanted device (11%). Only 4% (28/688) had a leadless cardiac device placement. The most common access sites were subclavian (47.1%), axillary (32.3%) and femoral (12.2%). CONCLUSIONS: The present study demonstrated that nearly one-third of the patient undergoing cardiac device placement had an advanced degree of renal failure. Because CKD is a progressive disease, many of these patients might require renal replacement therapy in the future. Transvenous devices is not a good choice in this group of patients as they will ultimately require an arteriovenous fistula. Subcutaneous leadless cardiac device insertion might be a better option in patients with advanced CKD. Elmer Press 2020-03 2020-03-02 /pmc/articles/PMC7092765/ /pubmed/32231754 http://dx.doi.org/10.14740/jocmr4075 Text en Copyright 2020, Hossain et al. http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Non-Commercial 4.0 International License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Hossain, Mohammad A.
Ajam, Firas
Mahida, Hetavi
Alrefaee, Anas
Patel, Swapnil
Agarwal, Khushboo
Alidoost, Marjan
Dahab, Shereen
Quinlan, Amy
Orange, Michael
Mushtaq, Arman
Asif, Arif
Chronic Kidney Disease in Patients Undergoing Cardiac Device Placement: Results of a Retrospective Study
title Chronic Kidney Disease in Patients Undergoing Cardiac Device Placement: Results of a Retrospective Study
title_full Chronic Kidney Disease in Patients Undergoing Cardiac Device Placement: Results of a Retrospective Study
title_fullStr Chronic Kidney Disease in Patients Undergoing Cardiac Device Placement: Results of a Retrospective Study
title_full_unstemmed Chronic Kidney Disease in Patients Undergoing Cardiac Device Placement: Results of a Retrospective Study
title_short Chronic Kidney Disease in Patients Undergoing Cardiac Device Placement: Results of a Retrospective Study
title_sort chronic kidney disease in patients undergoing cardiac device placement: results of a retrospective study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7092765/
https://www.ncbi.nlm.nih.gov/pubmed/32231754
http://dx.doi.org/10.14740/jocmr4075
work_keys_str_mv AT hossainmohammada chronickidneydiseaseinpatientsundergoingcardiacdeviceplacementresultsofaretrospectivestudy
AT ajamfiras chronickidneydiseaseinpatientsundergoingcardiacdeviceplacementresultsofaretrospectivestudy
AT mahidahetavi chronickidneydiseaseinpatientsundergoingcardiacdeviceplacementresultsofaretrospectivestudy
AT alrefaeeanas chronickidneydiseaseinpatientsundergoingcardiacdeviceplacementresultsofaretrospectivestudy
AT patelswapnil chronickidneydiseaseinpatientsundergoingcardiacdeviceplacementresultsofaretrospectivestudy
AT agarwalkhushboo chronickidneydiseaseinpatientsundergoingcardiacdeviceplacementresultsofaretrospectivestudy
AT alidoostmarjan chronickidneydiseaseinpatientsundergoingcardiacdeviceplacementresultsofaretrospectivestudy
AT dahabshereen chronickidneydiseaseinpatientsundergoingcardiacdeviceplacementresultsofaretrospectivestudy
AT quinlanamy chronickidneydiseaseinpatientsundergoingcardiacdeviceplacementresultsofaretrospectivestudy
AT orangemichael chronickidneydiseaseinpatientsundergoingcardiacdeviceplacementresultsofaretrospectivestudy
AT mushtaqarman chronickidneydiseaseinpatientsundergoingcardiacdeviceplacementresultsofaretrospectivestudy
AT asifarif chronickidneydiseaseinpatientsundergoingcardiacdeviceplacementresultsofaretrospectivestudy