Cargando…
Soluble CD30, the Immune Response, and Acute Rejection in Human Kidney Transplantation: A Systematic Review and Meta-Analysis
Soluble CD30 (sCD30) is considered to be a marker for the activated immune system in which T cells can damage the allograft. Some studies reported that post-transplant sCD30 can predict early acute rejection and can thereby be used as a biomarker to detect acute rejection. However, several other stu...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7093023/ https://www.ncbi.nlm.nih.gov/pubmed/32256486 http://dx.doi.org/10.3389/fimmu.2020.00295 |
_version_ | 1783510219429511168 |
---|---|
author | Mirzakhani, Mohammad Shahbazi, Mehdi Akbari, Roghayeh Dedinská, Ivana Nemati, Eghlim Mohammadnia-Afrouzi, Mousa |
author_facet | Mirzakhani, Mohammad Shahbazi, Mehdi Akbari, Roghayeh Dedinská, Ivana Nemati, Eghlim Mohammadnia-Afrouzi, Mousa |
author_sort | Mirzakhani, Mohammad |
collection | PubMed |
description | Soluble CD30 (sCD30) is considered to be a marker for the activated immune system in which T cells can damage the allograft. Some studies reported that post-transplant sCD30 can predict early acute rejection and can thereby be used as a biomarker to detect acute rejection. However, several other studies found no relation between post-transplant sCD30 and acute rejection. This meta-analysis study aims to answer this main question of whether sCD30 can help clinicians to monitor transplant recipients. The electronic databases, including PubMed, Web of Science, ProQuest, Embase, Scopus, Google Scholar, the gray literature, and the key journals, were searched for observational studies from 1 January 1990 up to 30 April 2018. Eighteen studies, with a total of 1,453 patients, were included in this paper. With regard to the different measurement times, post-transplant sCD30 was separately analyzed and divided into five groups (i.e., 1, 2, 3, 4 week, and 1 month post-transplant sCD30). All groups indicated a strong association between sCD30 and the acute rejection. The standardized mean difference (SMD) is 1.22 in 1 week, 0.77 in 2 week, 1.11 in 3 week, 1.27 in 4 week, and 0.71 in 1 month groups. The association between sCD30 and acute rejection was consistent across all the subgroup analyses. We found that post-transplant sCD30 had a strong association with acute kidney rejection. We also found that the deceased donors had more association with the high amount of sCD30 than living donors in patients with acute rejection. Finally, we realized that donor type was an important factor leading to the heterogeneous results in the primary studies. |
format | Online Article Text |
id | pubmed-7093023 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-70930232020-03-31 Soluble CD30, the Immune Response, and Acute Rejection in Human Kidney Transplantation: A Systematic Review and Meta-Analysis Mirzakhani, Mohammad Shahbazi, Mehdi Akbari, Roghayeh Dedinská, Ivana Nemati, Eghlim Mohammadnia-Afrouzi, Mousa Front Immunol Immunology Soluble CD30 (sCD30) is considered to be a marker for the activated immune system in which T cells can damage the allograft. Some studies reported that post-transplant sCD30 can predict early acute rejection and can thereby be used as a biomarker to detect acute rejection. However, several other studies found no relation between post-transplant sCD30 and acute rejection. This meta-analysis study aims to answer this main question of whether sCD30 can help clinicians to monitor transplant recipients. The electronic databases, including PubMed, Web of Science, ProQuest, Embase, Scopus, Google Scholar, the gray literature, and the key journals, were searched for observational studies from 1 January 1990 up to 30 April 2018. Eighteen studies, with a total of 1,453 patients, were included in this paper. With regard to the different measurement times, post-transplant sCD30 was separately analyzed and divided into five groups (i.e., 1, 2, 3, 4 week, and 1 month post-transplant sCD30). All groups indicated a strong association between sCD30 and the acute rejection. The standardized mean difference (SMD) is 1.22 in 1 week, 0.77 in 2 week, 1.11 in 3 week, 1.27 in 4 week, and 0.71 in 1 month groups. The association between sCD30 and acute rejection was consistent across all the subgroup analyses. We found that post-transplant sCD30 had a strong association with acute kidney rejection. We also found that the deceased donors had more association with the high amount of sCD30 than living donors in patients with acute rejection. Finally, we realized that donor type was an important factor leading to the heterogeneous results in the primary studies. Frontiers Media S.A. 2020-02-28 /pmc/articles/PMC7093023/ /pubmed/32256486 http://dx.doi.org/10.3389/fimmu.2020.00295 Text en Copyright © 2020 Mirzakhani, Shahbazi, Akbari, Dedinská, Nemati and Mohammadnia-Afrouzi. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Immunology Mirzakhani, Mohammad Shahbazi, Mehdi Akbari, Roghayeh Dedinská, Ivana Nemati, Eghlim Mohammadnia-Afrouzi, Mousa Soluble CD30, the Immune Response, and Acute Rejection in Human Kidney Transplantation: A Systematic Review and Meta-Analysis |
title | Soluble CD30, the Immune Response, and Acute Rejection in Human Kidney Transplantation: A Systematic Review and Meta-Analysis |
title_full | Soluble CD30, the Immune Response, and Acute Rejection in Human Kidney Transplantation: A Systematic Review and Meta-Analysis |
title_fullStr | Soluble CD30, the Immune Response, and Acute Rejection in Human Kidney Transplantation: A Systematic Review and Meta-Analysis |
title_full_unstemmed | Soluble CD30, the Immune Response, and Acute Rejection in Human Kidney Transplantation: A Systematic Review and Meta-Analysis |
title_short | Soluble CD30, the Immune Response, and Acute Rejection in Human Kidney Transplantation: A Systematic Review and Meta-Analysis |
title_sort | soluble cd30, the immune response, and acute rejection in human kidney transplantation: a systematic review and meta-analysis |
topic | Immunology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7093023/ https://www.ncbi.nlm.nih.gov/pubmed/32256486 http://dx.doi.org/10.3389/fimmu.2020.00295 |
work_keys_str_mv | AT mirzakhanimohammad solublecd30theimmuneresponseandacuterejectioninhumankidneytransplantationasystematicreviewandmetaanalysis AT shahbazimehdi solublecd30theimmuneresponseandacuterejectioninhumankidneytransplantationasystematicreviewandmetaanalysis AT akbariroghayeh solublecd30theimmuneresponseandacuterejectioninhumankidneytransplantationasystematicreviewandmetaanalysis AT dedinskaivana solublecd30theimmuneresponseandacuterejectioninhumankidneytransplantationasystematicreviewandmetaanalysis AT nematieghlim solublecd30theimmuneresponseandacuterejectioninhumankidneytransplantationasystematicreviewandmetaanalysis AT mohammadniaafrouzimousa solublecd30theimmuneresponseandacuterejectioninhumankidneytransplantationasystematicreviewandmetaanalysis |