Cargando…
Comparison of Harmonic scalpel and monopolar cautery for capsulectomy at the second stage of expander/implant breast reconstruction
BACKGROUND: Capsular contracture is a common complication of two-stage expander/implant breast reconstruction. To minimize the risk of this complication, capsulectomy is performed using monopolar cautery or ultrasonic surgical instrumentation, the latter of which can be conducted with a Harmonic sca...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Plastic and Reconstructive Surgeons
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7093267/ https://www.ncbi.nlm.nih.gov/pubmed/32098006 http://dx.doi.org/10.5999/aps.2019.01130 |
_version_ | 1783510249094774784 |
---|---|
author | Kim, Ki Jae Chung, Jae Ho Lee, Hyung Chul Lee, Byung Il Park, Seung Ha Yoon, Eul Sik |
author_facet | Kim, Ki Jae Chung, Jae Ho Lee, Hyung Chul Lee, Byung Il Park, Seung Ha Yoon, Eul Sik |
author_sort | Kim, Ki Jae |
collection | PubMed |
description | BACKGROUND: Capsular contracture is a common complication of two-stage expander/implant breast reconstruction. To minimize the risk of this complication, capsulectomy is performed using monopolar cautery or ultrasonic surgical instrumentation, the latter of which can be conducted with a Harmonic scalpel. To date, there is disagreement regarding which of the two methods is superior. The purpose of this study was to compare postoperative outcomes between a group of patients who underwent surgery using a Harmonic scalpel and another group treated with monopolar cautery. METHODS: A retrospective chart review was conducted of patients who underwent capsulectomy as part of two-stage breast reconstruction between January 2018 and February 2019 and who received at least 1 month of follow-up after surgery. Operative time and postoperative outcomes, including drainage duration, were analyzed. RESULTS: In total, 36 female patients underwent capsulectomy. The monopolar group consisted of 18 patients and 22 breasts, while the Harmonic scalpel group consisted of 18 patients and 21 breasts. There was no statistically significant difference in demographics between the two groups. The Harmonic scalpel group had a significantly shorter mean drainage duration (6.65 days vs. 7.36 days) and a smaller mean total drainage volume (334.69 mL vs. 433.54 mL) than the monopolar cautery group (P<0.05). No statistically significant difference was observed with regard to seroma or hematoma formation. CONCLUSIONS: The Harmonic scalpel approach for capsulectomy reduced the total drainage volume and drainage duration compared to the monopolar cautery approach. Therefore, this approach could serve as a good alternative to electrocautery. |
format | Online Article Text |
id | pubmed-7093267 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Korean Society of Plastic and Reconstructive Surgeons |
record_format | MEDLINE/PubMed |
spelling | pubmed-70932672020-04-02 Comparison of Harmonic scalpel and monopolar cautery for capsulectomy at the second stage of expander/implant breast reconstruction Kim, Ki Jae Chung, Jae Ho Lee, Hyung Chul Lee, Byung Il Park, Seung Ha Yoon, Eul Sik Arch Plast Surg Original Article BACKGROUND: Capsular contracture is a common complication of two-stage expander/implant breast reconstruction. To minimize the risk of this complication, capsulectomy is performed using monopolar cautery or ultrasonic surgical instrumentation, the latter of which can be conducted with a Harmonic scalpel. To date, there is disagreement regarding which of the two methods is superior. The purpose of this study was to compare postoperative outcomes between a group of patients who underwent surgery using a Harmonic scalpel and another group treated with monopolar cautery. METHODS: A retrospective chart review was conducted of patients who underwent capsulectomy as part of two-stage breast reconstruction between January 2018 and February 2019 and who received at least 1 month of follow-up after surgery. Operative time and postoperative outcomes, including drainage duration, were analyzed. RESULTS: In total, 36 female patients underwent capsulectomy. The monopolar group consisted of 18 patients and 22 breasts, while the Harmonic scalpel group consisted of 18 patients and 21 breasts. There was no statistically significant difference in demographics between the two groups. The Harmonic scalpel group had a significantly shorter mean drainage duration (6.65 days vs. 7.36 days) and a smaller mean total drainage volume (334.69 mL vs. 433.54 mL) than the monopolar cautery group (P<0.05). No statistically significant difference was observed with regard to seroma or hematoma formation. CONCLUSIONS: The Harmonic scalpel approach for capsulectomy reduced the total drainage volume and drainage duration compared to the monopolar cautery approach. Therefore, this approach could serve as a good alternative to electrocautery. Korean Society of Plastic and Reconstructive Surgeons 2020-03 2020-02-27 /pmc/articles/PMC7093267/ /pubmed/32098006 http://dx.doi.org/10.5999/aps.2019.01130 Text en Copyright © 2020 The Korean Society of Plastic and Reconstructive Surgeons This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, Ki Jae Chung, Jae Ho Lee, Hyung Chul Lee, Byung Il Park, Seung Ha Yoon, Eul Sik Comparison of Harmonic scalpel and monopolar cautery for capsulectomy at the second stage of expander/implant breast reconstruction |
title | Comparison of Harmonic scalpel and monopolar cautery for capsulectomy at the second stage of expander/implant breast reconstruction |
title_full | Comparison of Harmonic scalpel and monopolar cautery for capsulectomy at the second stage of expander/implant breast reconstruction |
title_fullStr | Comparison of Harmonic scalpel and monopolar cautery for capsulectomy at the second stage of expander/implant breast reconstruction |
title_full_unstemmed | Comparison of Harmonic scalpel and monopolar cautery for capsulectomy at the second stage of expander/implant breast reconstruction |
title_short | Comparison of Harmonic scalpel and monopolar cautery for capsulectomy at the second stage of expander/implant breast reconstruction |
title_sort | comparison of harmonic scalpel and monopolar cautery for capsulectomy at the second stage of expander/implant breast reconstruction |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7093267/ https://www.ncbi.nlm.nih.gov/pubmed/32098006 http://dx.doi.org/10.5999/aps.2019.01130 |
work_keys_str_mv | AT kimkijae comparisonofharmonicscalpelandmonopolarcauteryforcapsulectomyatthesecondstageofexpanderimplantbreastreconstruction AT chungjaeho comparisonofharmonicscalpelandmonopolarcauteryforcapsulectomyatthesecondstageofexpanderimplantbreastreconstruction AT leehyungchul comparisonofharmonicscalpelandmonopolarcauteryforcapsulectomyatthesecondstageofexpanderimplantbreastreconstruction AT leebyungil comparisonofharmonicscalpelandmonopolarcauteryforcapsulectomyatthesecondstageofexpanderimplantbreastreconstruction AT parkseungha comparisonofharmonicscalpelandmonopolarcauteryforcapsulectomyatthesecondstageofexpanderimplantbreastreconstruction AT yooneulsik comparisonofharmonicscalpelandmonopolarcauteryforcapsulectomyatthesecondstageofexpanderimplantbreastreconstruction |