Cargando…
Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population
BACKGROUND: Infrabrow blepharoplasty has become a common surgical method used to rejuvenate aged upper eyelids in Asians. In this paper, we describe the parallel excision method for infrabrow blepharoplasty as a useful alternative to the conventional elliptical excision method. The authors’ experien...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Plastic and Reconstructive Surgeons
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7093278/ https://www.ncbi.nlm.nih.gov/pubmed/32203995 http://dx.doi.org/10.5999/aps.2019.01102 |
_version_ | 1783510251655397376 |
---|---|
author | Lee, Yoon Jae Kim, SeongAe Lee, Jisung Chung, Joong Geel Jun, Young Joon |
author_facet | Lee, Yoon Jae Kim, SeongAe Lee, Jisung Chung, Joong Geel Jun, Young Joon |
author_sort | Lee, Yoon Jae |
collection | PubMed |
description | BACKGROUND: Infrabrow blepharoplasty has become a common surgical method used to rejuvenate aged upper eyelids in Asians. In this paper, we describe the parallel excision method for infrabrow blepharoplasty as a useful alternative to the conventional elliptical excision method. The authors’ experience over a 3-year period is presented and reviewed. METHODS: A retrospective review of parallel excision infrabrow blepharoplasty cases at our hospital between 2014 and 2017 was performed. Three oculoplastic surgeons compared preoperative and postoperative photographs using the Strasser grading system. RESULTS: From the medical records of 123 patients, a total of 93 patients with moderate-to-severe bilateral dermatochalasis were selected as subjects. The exclusion criterion was levator function less than 8 mm. The total mean follow-up period was 2 years (range, 0.5–3.5 years). The mean skin excision height and width were 9.75 mm (range, 5–16 mm) and 58.51 mm (range, 42–75 mm), respectively. All patients who underwent surgery recovered without major complications, and all patients had high levels of satisfaction and improvements in their visual field. In the Strasser evaluation performed by the oculoplastic surgeons, most patients were found to have excellent results. CONCLUSIONS: The parallel excision method for infrabrow blepharoplasty is a safe and effective technique that yields more natural- and youthful-looking eyelids than the conventional elliptical excision method. In our method, more effective manipulation of the orbicularis oculi muscle led to a reduction in frontalis compensation, resolution of sunken eyelids, and correction of lateral hooding. |
format | Online Article Text |
id | pubmed-7093278 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Korean Society of Plastic and Reconstructive Surgeons |
record_format | MEDLINE/PubMed |
spelling | pubmed-70932782020-04-02 Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population Lee, Yoon Jae Kim, SeongAe Lee, Jisung Chung, Joong Geel Jun, Young Joon Arch Plast Surg Original Article BACKGROUND: Infrabrow blepharoplasty has become a common surgical method used to rejuvenate aged upper eyelids in Asians. In this paper, we describe the parallel excision method for infrabrow blepharoplasty as a useful alternative to the conventional elliptical excision method. The authors’ experience over a 3-year period is presented and reviewed. METHODS: A retrospective review of parallel excision infrabrow blepharoplasty cases at our hospital between 2014 and 2017 was performed. Three oculoplastic surgeons compared preoperative and postoperative photographs using the Strasser grading system. RESULTS: From the medical records of 123 patients, a total of 93 patients with moderate-to-severe bilateral dermatochalasis were selected as subjects. The exclusion criterion was levator function less than 8 mm. The total mean follow-up period was 2 years (range, 0.5–3.5 years). The mean skin excision height and width were 9.75 mm (range, 5–16 mm) and 58.51 mm (range, 42–75 mm), respectively. All patients who underwent surgery recovered without major complications, and all patients had high levels of satisfaction and improvements in their visual field. In the Strasser evaluation performed by the oculoplastic surgeons, most patients were found to have excellent results. CONCLUSIONS: The parallel excision method for infrabrow blepharoplasty is a safe and effective technique that yields more natural- and youthful-looking eyelids than the conventional elliptical excision method. In our method, more effective manipulation of the orbicularis oculi muscle led to a reduction in frontalis compensation, resolution of sunken eyelids, and correction of lateral hooding. Korean Society of Plastic and Reconstructive Surgeons 2020-03 2020-03-15 /pmc/articles/PMC7093278/ /pubmed/32203995 http://dx.doi.org/10.5999/aps.2019.01102 Text en Copyright © 2020 The Korean Society of Plastic and Reconstructive Surgeons This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Yoon Jae Kim, SeongAe Lee, Jisung Chung, Joong Geel Jun, Young Joon Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population |
title | Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population |
title_full | Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population |
title_fullStr | Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population |
title_full_unstemmed | Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population |
title_short | Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population |
title_sort | parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an asian population |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7093278/ https://www.ncbi.nlm.nih.gov/pubmed/32203995 http://dx.doi.org/10.5999/aps.2019.01102 |
work_keys_str_mv | AT leeyoonjae parallelexcisioninfrabrowblepharoplastywithextensiveexcisionoftheorbicularisoculimuscleinanasianpopulation AT kimseongae parallelexcisioninfrabrowblepharoplastywithextensiveexcisionoftheorbicularisoculimuscleinanasianpopulation AT leejisung parallelexcisioninfrabrowblepharoplastywithextensiveexcisionoftheorbicularisoculimuscleinanasianpopulation AT chungjoonggeel parallelexcisioninfrabrowblepharoplastywithextensiveexcisionoftheorbicularisoculimuscleinanasianpopulation AT junyoungjoon parallelexcisioninfrabrowblepharoplastywithextensiveexcisionoftheorbicularisoculimuscleinanasianpopulation |