Cargando…

Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population

BACKGROUND: Infrabrow blepharoplasty has become a common surgical method used to rejuvenate aged upper eyelids in Asians. In this paper, we describe the parallel excision method for infrabrow blepharoplasty as a useful alternative to the conventional elliptical excision method. The authors’ experien...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Yoon Jae, Kim, SeongAe, Lee, Jisung, Chung, Joong Geel, Jun, Young Joon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Plastic and Reconstructive Surgeons 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7093278/
https://www.ncbi.nlm.nih.gov/pubmed/32203995
http://dx.doi.org/10.5999/aps.2019.01102
_version_ 1783510251655397376
author Lee, Yoon Jae
Kim, SeongAe
Lee, Jisung
Chung, Joong Geel
Jun, Young Joon
author_facet Lee, Yoon Jae
Kim, SeongAe
Lee, Jisung
Chung, Joong Geel
Jun, Young Joon
author_sort Lee, Yoon Jae
collection PubMed
description BACKGROUND: Infrabrow blepharoplasty has become a common surgical method used to rejuvenate aged upper eyelids in Asians. In this paper, we describe the parallel excision method for infrabrow blepharoplasty as a useful alternative to the conventional elliptical excision method. The authors’ experience over a 3-year period is presented and reviewed. METHODS: A retrospective review of parallel excision infrabrow blepharoplasty cases at our hospital between 2014 and 2017 was performed. Three oculoplastic surgeons compared preoperative and postoperative photographs using the Strasser grading system. RESULTS: From the medical records of 123 patients, a total of 93 patients with moderate-to-severe bilateral dermatochalasis were selected as subjects. The exclusion criterion was levator function less than 8 mm. The total mean follow-up period was 2 years (range, 0.5–3.5 years). The mean skin excision height and width were 9.75 mm (range, 5–16 mm) and 58.51 mm (range, 42–75 mm), respectively. All patients who underwent surgery recovered without major complications, and all patients had high levels of satisfaction and improvements in their visual field. In the Strasser evaluation performed by the oculoplastic surgeons, most patients were found to have excellent results. CONCLUSIONS: The parallel excision method for infrabrow blepharoplasty is a safe and effective technique that yields more natural- and youthful-looking eyelids than the conventional elliptical excision method. In our method, more effective manipulation of the orbicularis oculi muscle led to a reduction in frontalis compensation, resolution of sunken eyelids, and correction of lateral hooding.
format Online
Article
Text
id pubmed-7093278
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Korean Society of Plastic and Reconstructive Surgeons
record_format MEDLINE/PubMed
spelling pubmed-70932782020-04-02 Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population Lee, Yoon Jae Kim, SeongAe Lee, Jisung Chung, Joong Geel Jun, Young Joon Arch Plast Surg Original Article BACKGROUND: Infrabrow blepharoplasty has become a common surgical method used to rejuvenate aged upper eyelids in Asians. In this paper, we describe the parallel excision method for infrabrow blepharoplasty as a useful alternative to the conventional elliptical excision method. The authors’ experience over a 3-year period is presented and reviewed. METHODS: A retrospective review of parallel excision infrabrow blepharoplasty cases at our hospital between 2014 and 2017 was performed. Three oculoplastic surgeons compared preoperative and postoperative photographs using the Strasser grading system. RESULTS: From the medical records of 123 patients, a total of 93 patients with moderate-to-severe bilateral dermatochalasis were selected as subjects. The exclusion criterion was levator function less than 8 mm. The total mean follow-up period was 2 years (range, 0.5–3.5 years). The mean skin excision height and width were 9.75 mm (range, 5–16 mm) and 58.51 mm (range, 42–75 mm), respectively. All patients who underwent surgery recovered without major complications, and all patients had high levels of satisfaction and improvements in their visual field. In the Strasser evaluation performed by the oculoplastic surgeons, most patients were found to have excellent results. CONCLUSIONS: The parallel excision method for infrabrow blepharoplasty is a safe and effective technique that yields more natural- and youthful-looking eyelids than the conventional elliptical excision method. In our method, more effective manipulation of the orbicularis oculi muscle led to a reduction in frontalis compensation, resolution of sunken eyelids, and correction of lateral hooding. Korean Society of Plastic and Reconstructive Surgeons 2020-03 2020-03-15 /pmc/articles/PMC7093278/ /pubmed/32203995 http://dx.doi.org/10.5999/aps.2019.01102 Text en Copyright © 2020 The Korean Society of Plastic and Reconstructive Surgeons This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Yoon Jae
Kim, SeongAe
Lee, Jisung
Chung, Joong Geel
Jun, Young Joon
Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population
title Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population
title_full Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population
title_fullStr Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population
title_full_unstemmed Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population
title_short Parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an Asian population
title_sort parallel-excision infrabrow blepharoplasty with extensive excision of the orbicularis oculi muscle in an asian population
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7093278/
https://www.ncbi.nlm.nih.gov/pubmed/32203995
http://dx.doi.org/10.5999/aps.2019.01102
work_keys_str_mv AT leeyoonjae parallelexcisioninfrabrowblepharoplastywithextensiveexcisionoftheorbicularisoculimuscleinanasianpopulation
AT kimseongae parallelexcisioninfrabrowblepharoplastywithextensiveexcisionoftheorbicularisoculimuscleinanasianpopulation
AT leejisung parallelexcisioninfrabrowblepharoplastywithextensiveexcisionoftheorbicularisoculimuscleinanasianpopulation
AT chungjoonggeel parallelexcisioninfrabrowblepharoplastywithextensiveexcisionoftheorbicularisoculimuscleinanasianpopulation
AT junyoungjoon parallelexcisioninfrabrowblepharoplastywithextensiveexcisionoftheorbicularisoculimuscleinanasianpopulation