Cargando…
Coracoclavicular Stabilization With Two Loops of Equal Tension Using a Double O Loops Technique in the Distal Clavicle Fracture
The distal clavicle fracture is one of the most common injuries around the shoulder joint. There is no consensus regarding a gold standard treatment. Each technique has advantages and disadvantages. Currently, coracoclavicular (CC) stabilization is one of the most popular techniques because this ope...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7093728/ https://www.ncbi.nlm.nih.gov/pubmed/32226741 http://dx.doi.org/10.1016/j.eats.2019.11.010 |
_version_ | 1783510337028358144 |
---|---|
author | Chuaychoosakoon, Chaiwat Duangnumsawang, Yada Klabklay, Prapakorn Boonriong, Tanarat Apivatgaroon, Adinun |
author_facet | Chuaychoosakoon, Chaiwat Duangnumsawang, Yada Klabklay, Prapakorn Boonriong, Tanarat Apivatgaroon, Adinun |
author_sort | Chuaychoosakoon, Chaiwat |
collection | PubMed |
description | The distal clavicle fracture is one of the most common injuries around the shoulder joint. There is no consensus regarding a gold standard treatment. Each technique has advantages and disadvantages. Currently, coracoclavicular (CC) stabilization is one of the most popular techniques because this operative procedure provides good stability of the fracture and has few complications. The CC stabilization is a suspensory fixation that consists of many two-CC-loop arrangements. It is, however, difficult to gain equal tension in both CC loops because one loop is always tighter and has greater action in maintaining bone alignment than the other loop. To solve this problem, we propose a double O loops technique to achieve two equal tension loops. |
format | Online Article Text |
id | pubmed-7093728 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-70937282020-03-27 Coracoclavicular Stabilization With Two Loops of Equal Tension Using a Double O Loops Technique in the Distal Clavicle Fracture Chuaychoosakoon, Chaiwat Duangnumsawang, Yada Klabklay, Prapakorn Boonriong, Tanarat Apivatgaroon, Adinun Arthrosc Tech Technical Note The distal clavicle fracture is one of the most common injuries around the shoulder joint. There is no consensus regarding a gold standard treatment. Each technique has advantages and disadvantages. Currently, coracoclavicular (CC) stabilization is one of the most popular techniques because this operative procedure provides good stability of the fracture and has few complications. The CC stabilization is a suspensory fixation that consists of many two-CC-loop arrangements. It is, however, difficult to gain equal tension in both CC loops because one loop is always tighter and has greater action in maintaining bone alignment than the other loop. To solve this problem, we propose a double O loops technique to achieve two equal tension loops. Elsevier 2020-02-07 /pmc/articles/PMC7093728/ /pubmed/32226741 http://dx.doi.org/10.1016/j.eats.2019.11.010 Text en © 2019 by the Arthroscopy Association of North America. Published by Elsevier. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Technical Note Chuaychoosakoon, Chaiwat Duangnumsawang, Yada Klabklay, Prapakorn Boonriong, Tanarat Apivatgaroon, Adinun Coracoclavicular Stabilization With Two Loops of Equal Tension Using a Double O Loops Technique in the Distal Clavicle Fracture |
title | Coracoclavicular Stabilization With Two Loops of Equal Tension Using a Double O Loops Technique in the Distal Clavicle Fracture |
title_full | Coracoclavicular Stabilization With Two Loops of Equal Tension Using a Double O Loops Technique in the Distal Clavicle Fracture |
title_fullStr | Coracoclavicular Stabilization With Two Loops of Equal Tension Using a Double O Loops Technique in the Distal Clavicle Fracture |
title_full_unstemmed | Coracoclavicular Stabilization With Two Loops of Equal Tension Using a Double O Loops Technique in the Distal Clavicle Fracture |
title_short | Coracoclavicular Stabilization With Two Loops of Equal Tension Using a Double O Loops Technique in the Distal Clavicle Fracture |
title_sort | coracoclavicular stabilization with two loops of equal tension using a double o loops technique in the distal clavicle fracture |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7093728/ https://www.ncbi.nlm.nih.gov/pubmed/32226741 http://dx.doi.org/10.1016/j.eats.2019.11.010 |
work_keys_str_mv | AT chuaychoosakoonchaiwat coracoclavicularstabilizationwithtwoloopsofequaltensionusingadoubleoloopstechniqueinthedistalclaviclefracture AT duangnumsawangyada coracoclavicularstabilizationwithtwoloopsofequaltensionusingadoubleoloopstechniqueinthedistalclaviclefracture AT klabklayprapakorn coracoclavicularstabilizationwithtwoloopsofequaltensionusingadoubleoloopstechniqueinthedistalclaviclefracture AT boonriongtanarat coracoclavicularstabilizationwithtwoloopsofequaltensionusingadoubleoloopstechniqueinthedistalclaviclefracture AT apivatgaroonadinun coracoclavicularstabilizationwithtwoloopsofequaltensionusingadoubleoloopstechniqueinthedistalclaviclefracture |