Cargando…

Coracoclavicular Stabilization With Two Loops of Equal Tension Using a Double O Loops Technique in the Distal Clavicle Fracture

The distal clavicle fracture is one of the most common injuries around the shoulder joint. There is no consensus regarding a gold standard treatment. Each technique has advantages and disadvantages. Currently, coracoclavicular (CC) stabilization is one of the most popular techniques because this ope...

Descripción completa

Detalles Bibliográficos
Autores principales: Chuaychoosakoon, Chaiwat, Duangnumsawang, Yada, Klabklay, Prapakorn, Boonriong, Tanarat, Apivatgaroon, Adinun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7093728/
https://www.ncbi.nlm.nih.gov/pubmed/32226741
http://dx.doi.org/10.1016/j.eats.2019.11.010
_version_ 1783510337028358144
author Chuaychoosakoon, Chaiwat
Duangnumsawang, Yada
Klabklay, Prapakorn
Boonriong, Tanarat
Apivatgaroon, Adinun
author_facet Chuaychoosakoon, Chaiwat
Duangnumsawang, Yada
Klabklay, Prapakorn
Boonriong, Tanarat
Apivatgaroon, Adinun
author_sort Chuaychoosakoon, Chaiwat
collection PubMed
description The distal clavicle fracture is one of the most common injuries around the shoulder joint. There is no consensus regarding a gold standard treatment. Each technique has advantages and disadvantages. Currently, coracoclavicular (CC) stabilization is one of the most popular techniques because this operative procedure provides good stability of the fracture and has few complications. The CC stabilization is a suspensory fixation that consists of many two-CC-loop arrangements. It is, however, difficult to gain equal tension in both CC loops because one loop is always tighter and has greater action in maintaining bone alignment than the other loop. To solve this problem, we propose a double O loops technique to achieve two equal tension loops.
format Online
Article
Text
id pubmed-7093728
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-70937282020-03-27 Coracoclavicular Stabilization With Two Loops of Equal Tension Using a Double O Loops Technique in the Distal Clavicle Fracture Chuaychoosakoon, Chaiwat Duangnumsawang, Yada Klabklay, Prapakorn Boonriong, Tanarat Apivatgaroon, Adinun Arthrosc Tech Technical Note The distal clavicle fracture is one of the most common injuries around the shoulder joint. There is no consensus regarding a gold standard treatment. Each technique has advantages and disadvantages. Currently, coracoclavicular (CC) stabilization is one of the most popular techniques because this operative procedure provides good stability of the fracture and has few complications. The CC stabilization is a suspensory fixation that consists of many two-CC-loop arrangements. It is, however, difficult to gain equal tension in both CC loops because one loop is always tighter and has greater action in maintaining bone alignment than the other loop. To solve this problem, we propose a double O loops technique to achieve two equal tension loops. Elsevier 2020-02-07 /pmc/articles/PMC7093728/ /pubmed/32226741 http://dx.doi.org/10.1016/j.eats.2019.11.010 Text en © 2019 by the Arthroscopy Association of North America. Published by Elsevier. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Technical Note
Chuaychoosakoon, Chaiwat
Duangnumsawang, Yada
Klabklay, Prapakorn
Boonriong, Tanarat
Apivatgaroon, Adinun
Coracoclavicular Stabilization With Two Loops of Equal Tension Using a Double O Loops Technique in the Distal Clavicle Fracture
title Coracoclavicular Stabilization With Two Loops of Equal Tension Using a Double O Loops Technique in the Distal Clavicle Fracture
title_full Coracoclavicular Stabilization With Two Loops of Equal Tension Using a Double O Loops Technique in the Distal Clavicle Fracture
title_fullStr Coracoclavicular Stabilization With Two Loops of Equal Tension Using a Double O Loops Technique in the Distal Clavicle Fracture
title_full_unstemmed Coracoclavicular Stabilization With Two Loops of Equal Tension Using a Double O Loops Technique in the Distal Clavicle Fracture
title_short Coracoclavicular Stabilization With Two Loops of Equal Tension Using a Double O Loops Technique in the Distal Clavicle Fracture
title_sort coracoclavicular stabilization with two loops of equal tension using a double o loops technique in the distal clavicle fracture
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7093728/
https://www.ncbi.nlm.nih.gov/pubmed/32226741
http://dx.doi.org/10.1016/j.eats.2019.11.010
work_keys_str_mv AT chuaychoosakoonchaiwat coracoclavicularstabilizationwithtwoloopsofequaltensionusingadoubleoloopstechniqueinthedistalclaviclefracture
AT duangnumsawangyada coracoclavicularstabilizationwithtwoloopsofequaltensionusingadoubleoloopstechniqueinthedistalclaviclefracture
AT klabklayprapakorn coracoclavicularstabilizationwithtwoloopsofequaltensionusingadoubleoloopstechniqueinthedistalclaviclefracture
AT boonriongtanarat coracoclavicularstabilizationwithtwoloopsofequaltensionusingadoubleoloopstechniqueinthedistalclaviclefracture
AT apivatgaroonadinun coracoclavicularstabilizationwithtwoloopsofequaltensionusingadoubleoloopstechniqueinthedistalclaviclefracture