Cargando…

Biomechanical Analysis of Various Reconstructive Methods for the Mandibular Body and Ramus Defect Using a Free Vascularized Fibula Flap

Several different methods exist for reconstructing the mandibular body and ramus defect with the use of a free vascularized fibula flap, but none have adequately addressed the long-term mechanical stability and osseointegration. The aim of this study is to compare the biomechanics of different surgi...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Xian, Jiang, Chao, Gao, Hui, Wang, Chunjuan, Wang, Chao, Ji, Ping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7094202/
https://www.ncbi.nlm.nih.gov/pubmed/32258153
http://dx.doi.org/10.1155/2020/8797493
_version_ 1783510420656488448
author Li, Xian
Jiang, Chao
Gao, Hui
Wang, Chunjuan
Wang, Chao
Ji, Ping
author_facet Li, Xian
Jiang, Chao
Gao, Hui
Wang, Chunjuan
Wang, Chao
Ji, Ping
author_sort Li, Xian
collection PubMed
description Several different methods exist for reconstructing the mandibular body and ramus defect with the use of a free vascularized fibula flap, but none have adequately addressed the long-term mechanical stability and osseointegration. The aim of this study is to compare the biomechanics of different surgical methods and to investigate the best approach for reconstructing the mandibular body and ramus defect. Five finite element models based on different reconstructive methods were simulated. Stress, strain, and displacement of connective bone sections were calculated for five models and compared. The models were printed using a 3D printer, and stiffness was measured using an electromechanical universal testing machine. The postoperative follow-up cone beam computed tomography (CBCT) was taken at different time points to analyze bone mineral density of connective bone sections. The results showed that the “double up” (DU) model was the most efficient for reconstructing a mandibular body and ramus defect by comparing the mechanical distribution of three sections under vertical and inclined loading conditions of 100 N. The stiffness detection showed that stiffness in the DU and “double down” (DD) models was higher compared with the “single up” (SU), “single down” (SD), and “distraction osteogenesis” (DO) models. We used the DU model for the surgery, and postoperative follow-up CBCT showed that bone mineral density of each fibular connective section increased gradually with time, plateauing at 12 weeks. We conclude that a free vascularized fibula flap of the DU type was the best approach for the reconstruction of the mandibular body and ramus defect. Preoperative finite element analysis and stiffness testing were shown to be very useful for maxillofacial reconstruction.
format Online
Article
Text
id pubmed-7094202
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-70942022020-04-04 Biomechanical Analysis of Various Reconstructive Methods for the Mandibular Body and Ramus Defect Using a Free Vascularized Fibula Flap Li, Xian Jiang, Chao Gao, Hui Wang, Chunjuan Wang, Chao Ji, Ping Biomed Res Int Research Article Several different methods exist for reconstructing the mandibular body and ramus defect with the use of a free vascularized fibula flap, but none have adequately addressed the long-term mechanical stability and osseointegration. The aim of this study is to compare the biomechanics of different surgical methods and to investigate the best approach for reconstructing the mandibular body and ramus defect. Five finite element models based on different reconstructive methods were simulated. Stress, strain, and displacement of connective bone sections were calculated for five models and compared. The models were printed using a 3D printer, and stiffness was measured using an electromechanical universal testing machine. The postoperative follow-up cone beam computed tomography (CBCT) was taken at different time points to analyze bone mineral density of connective bone sections. The results showed that the “double up” (DU) model was the most efficient for reconstructing a mandibular body and ramus defect by comparing the mechanical distribution of three sections under vertical and inclined loading conditions of 100 N. The stiffness detection showed that stiffness in the DU and “double down” (DD) models was higher compared with the “single up” (SU), “single down” (SD), and “distraction osteogenesis” (DO) models. We used the DU model for the surgery, and postoperative follow-up CBCT showed that bone mineral density of each fibular connective section increased gradually with time, plateauing at 12 weeks. We conclude that a free vascularized fibula flap of the DU type was the best approach for the reconstruction of the mandibular body and ramus defect. Preoperative finite element analysis and stiffness testing were shown to be very useful for maxillofacial reconstruction. Hindawi 2020-03-13 /pmc/articles/PMC7094202/ /pubmed/32258153 http://dx.doi.org/10.1155/2020/8797493 Text en Copyright © 2020 Xian Li et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Li, Xian
Jiang, Chao
Gao, Hui
Wang, Chunjuan
Wang, Chao
Ji, Ping
Biomechanical Analysis of Various Reconstructive Methods for the Mandibular Body and Ramus Defect Using a Free Vascularized Fibula Flap
title Biomechanical Analysis of Various Reconstructive Methods for the Mandibular Body and Ramus Defect Using a Free Vascularized Fibula Flap
title_full Biomechanical Analysis of Various Reconstructive Methods for the Mandibular Body and Ramus Defect Using a Free Vascularized Fibula Flap
title_fullStr Biomechanical Analysis of Various Reconstructive Methods for the Mandibular Body and Ramus Defect Using a Free Vascularized Fibula Flap
title_full_unstemmed Biomechanical Analysis of Various Reconstructive Methods for the Mandibular Body and Ramus Defect Using a Free Vascularized Fibula Flap
title_short Biomechanical Analysis of Various Reconstructive Methods for the Mandibular Body and Ramus Defect Using a Free Vascularized Fibula Flap
title_sort biomechanical analysis of various reconstructive methods for the mandibular body and ramus defect using a free vascularized fibula flap
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7094202/
https://www.ncbi.nlm.nih.gov/pubmed/32258153
http://dx.doi.org/10.1155/2020/8797493
work_keys_str_mv AT lixian biomechanicalanalysisofvariousreconstructivemethodsforthemandibularbodyandramusdefectusingafreevascularizedfibulaflap
AT jiangchao biomechanicalanalysisofvariousreconstructivemethodsforthemandibularbodyandramusdefectusingafreevascularizedfibulaflap
AT gaohui biomechanicalanalysisofvariousreconstructivemethodsforthemandibularbodyandramusdefectusingafreevascularizedfibulaflap
AT wangchunjuan biomechanicalanalysisofvariousreconstructivemethodsforthemandibularbodyandramusdefectusingafreevascularizedfibulaflap
AT wangchao biomechanicalanalysisofvariousreconstructivemethodsforthemandibularbodyandramusdefectusingafreevascularizedfibulaflap
AT jiping biomechanicalanalysisofvariousreconstructivemethodsforthemandibularbodyandramusdefectusingafreevascularizedfibulaflap