Cargando…
Comparison of the efficiency of antibody selection from semi-synthetic scFv and non-immune Fab phage display libraries against protein targets for rapid development of diagnostic immunoassays
Rapid development of diagnostic immunoassays against novel emerging or genetically modified pathogens in an emergency situation is dependent on the timely isolation of specific antibodies. Non-immune antibody phage display libraries are an efficient in vitro method for selecting monoclonal antibodie...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier B.V.
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7094349/ https://www.ncbi.nlm.nih.gov/pubmed/21856306 http://dx.doi.org/10.1016/j.jim.2011.08.005 |
_version_ | 1783510452429389824 |
---|---|
author | Chan, Conrad E.Z. Chan, Annie H.Y. Lim, Angeline P.C. Hanson, Brendon J. |
author_facet | Chan, Conrad E.Z. Chan, Annie H.Y. Lim, Angeline P.C. Hanson, Brendon J. |
author_sort | Chan, Conrad E.Z. |
collection | PubMed |
description | Rapid development of diagnostic immunoassays against novel emerging or genetically modified pathogens in an emergency situation is dependent on the timely isolation of specific antibodies. Non-immune antibody phage display libraries are an efficient in vitro method for selecting monoclonal antibodies and hence ideal in these circumstances. Such libraries can be constructed from a variety of sources e.g. B cell cDNA or synthetically generated, and use a variety of antibody formats, typically scFv or Fab. However, antibody source and format can impact on the quality of antibodies generated and hence the effectiveness of this methodology for the timely production of antibodies. We have carried out a comparative screening of two antibody libraries, a semi-synthetic scFv library and a human-derived Fab library against the protective antigen toxin component of Bacillus anthracis and the epsilon toxin of Clostridium botulinum. We have shown that while the synthetic library produced a diverse collection of specific scFv-phage, these contained a high frequency of unnatural amber stops and glycosylation sites which limited their conversion to IgG, and also a high number which lost specificity when expressed as IgG. In contrast, these limitations were overcome by the use of a natural human library. Antibodies from both libraries could be used to develop sandwich ELISA assays with similar sensitivity. However, the ease and speed with which full-length IgG could be generated from the human-derived Fab library makes screening this type of library the preferable method for rapid antibody generation for diagnostic assay development. |
format | Online Article Text |
id | pubmed-7094349 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Elsevier B.V. |
record_format | MEDLINE/PubMed |
spelling | pubmed-70943492020-03-25 Comparison of the efficiency of antibody selection from semi-synthetic scFv and non-immune Fab phage display libraries against protein targets for rapid development of diagnostic immunoassays Chan, Conrad E.Z. Chan, Annie H.Y. Lim, Angeline P.C. Hanson, Brendon J. J Immunol Methods Article Rapid development of diagnostic immunoassays against novel emerging or genetically modified pathogens in an emergency situation is dependent on the timely isolation of specific antibodies. Non-immune antibody phage display libraries are an efficient in vitro method for selecting monoclonal antibodies and hence ideal in these circumstances. Such libraries can be constructed from a variety of sources e.g. B cell cDNA or synthetically generated, and use a variety of antibody formats, typically scFv or Fab. However, antibody source and format can impact on the quality of antibodies generated and hence the effectiveness of this methodology for the timely production of antibodies. We have carried out a comparative screening of two antibody libraries, a semi-synthetic scFv library and a human-derived Fab library against the protective antigen toxin component of Bacillus anthracis and the epsilon toxin of Clostridium botulinum. We have shown that while the synthetic library produced a diverse collection of specific scFv-phage, these contained a high frequency of unnatural amber stops and glycosylation sites which limited their conversion to IgG, and also a high number which lost specificity when expressed as IgG. In contrast, these limitations were overcome by the use of a natural human library. Antibodies from both libraries could be used to develop sandwich ELISA assays with similar sensitivity. However, the ease and speed with which full-length IgG could be generated from the human-derived Fab library makes screening this type of library the preferable method for rapid antibody generation for diagnostic assay development. Elsevier B.V. 2011-10-28 2011-08-12 /pmc/articles/PMC7094349/ /pubmed/21856306 http://dx.doi.org/10.1016/j.jim.2011.08.005 Text en Copyright © 2011 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Chan, Conrad E.Z. Chan, Annie H.Y. Lim, Angeline P.C. Hanson, Brendon J. Comparison of the efficiency of antibody selection from semi-synthetic scFv and non-immune Fab phage display libraries against protein targets for rapid development of diagnostic immunoassays |
title | Comparison of the efficiency of antibody selection from semi-synthetic scFv and non-immune Fab phage display libraries against protein targets for rapid development of diagnostic immunoassays |
title_full | Comparison of the efficiency of antibody selection from semi-synthetic scFv and non-immune Fab phage display libraries against protein targets for rapid development of diagnostic immunoassays |
title_fullStr | Comparison of the efficiency of antibody selection from semi-synthetic scFv and non-immune Fab phage display libraries against protein targets for rapid development of diagnostic immunoassays |
title_full_unstemmed | Comparison of the efficiency of antibody selection from semi-synthetic scFv and non-immune Fab phage display libraries against protein targets for rapid development of diagnostic immunoassays |
title_short | Comparison of the efficiency of antibody selection from semi-synthetic scFv and non-immune Fab phage display libraries against protein targets for rapid development of diagnostic immunoassays |
title_sort | comparison of the efficiency of antibody selection from semi-synthetic scfv and non-immune fab phage display libraries against protein targets for rapid development of diagnostic immunoassays |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7094349/ https://www.ncbi.nlm.nih.gov/pubmed/21856306 http://dx.doi.org/10.1016/j.jim.2011.08.005 |
work_keys_str_mv | AT chanconradez comparisonoftheefficiencyofantibodyselectionfromsemisyntheticscfvandnonimmunefabphagedisplaylibrariesagainstproteintargetsforrapiddevelopmentofdiagnosticimmunoassays AT chananniehy comparisonoftheefficiencyofantibodyselectionfromsemisyntheticscfvandnonimmunefabphagedisplaylibrariesagainstproteintargetsforrapiddevelopmentofdiagnosticimmunoassays AT limangelinepc comparisonoftheefficiencyofantibodyselectionfromsemisyntheticscfvandnonimmunefabphagedisplaylibrariesagainstproteintargetsforrapiddevelopmentofdiagnosticimmunoassays AT hansonbrendonj comparisonoftheefficiencyofantibodyselectionfromsemisyntheticscfvandnonimmunefabphagedisplaylibrariesagainstproteintargetsforrapiddevelopmentofdiagnosticimmunoassays |