Cargando…

Combination of multiplex reverse-transcription loop-mediated isothermal amplification with an immunochromatographic strip for subtyping influenza A virus

Considering the fatal human victims and economic loss by the annual epidemic influenza virus, the development of a rapid and convenient genetic analysis methodology is demanding for timely on-site pathogen detection. In this study, we utilized reverse-transcription loop-mediated isothermal amplifica...

Descripción completa

Detalles Bibliográficos
Autores principales: Jung, Jae Hwan, Oh, Seung Jun, Kim, Yong Tae, Kim, So Yeon, Kim, Won-Jung, Jung, Jaean, Seo, Tae Seok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier B.V. 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7094724/
https://www.ncbi.nlm.nih.gov/pubmed/25467501
http://dx.doi.org/10.1016/j.aca.2014.10.020
_version_ 1783510529053032448
author Jung, Jae Hwan
Oh, Seung Jun
Kim, Yong Tae
Kim, So Yeon
Kim, Won-Jung
Jung, Jaean
Seo, Tae Seok
author_facet Jung, Jae Hwan
Oh, Seung Jun
Kim, Yong Tae
Kim, So Yeon
Kim, Won-Jung
Jung, Jaean
Seo, Tae Seok
author_sort Jung, Jae Hwan
collection PubMed
description Considering the fatal human victims and economic loss by the annual epidemic influenza virus, the development of a rapid and convenient genetic analysis methodology is demanding for timely on-site pathogen detection. In this study, we utilized reverse-transcription loop-mediated isothermal amplification (RT-LAMP) for multiplex target gene amplification, and the resultant amplicons were analyzed on the immunochromatographic strip (ICS) for subtyping influenza A virus. Through the optimized primer design, reaction temperature and time, and concentration of enzymes (Bst DNA polymerase and AMV reverse transcriptase) and dNTP, the HA (H1, H3, and H5 gene) and conserved M gene were amplified. The ICS contains two test lines in addition to a control line in order to detect the presence of the HA and M gene, thereby informing us of influenza virus A type as well as its subtype (H1N1, H3N2, and H5N1). The combination of the multiplex RT-LAMP with the ICS could be complete in 40 min and the pathotyping and subtyping of influenza A virus were performed even with 10 copies of viral RNA templates. Moreover, the subtyping of clinical samples, which were obtained from patients infected by influenza A virus was successfully confirmed using the multiplex RT-LAMP and ICS techniques, showing great feasibility of our methodology for real sample analysis with high speed, simplicity and sensitivity.
format Online
Article
Text
id pubmed-7094724
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Elsevier B.V.
record_format MEDLINE/PubMed
spelling pubmed-70947242020-03-25 Combination of multiplex reverse-transcription loop-mediated isothermal amplification with an immunochromatographic strip for subtyping influenza A virus Jung, Jae Hwan Oh, Seung Jun Kim, Yong Tae Kim, So Yeon Kim, Won-Jung Jung, Jaean Seo, Tae Seok Anal Chim Acta Article Considering the fatal human victims and economic loss by the annual epidemic influenza virus, the development of a rapid and convenient genetic analysis methodology is demanding for timely on-site pathogen detection. In this study, we utilized reverse-transcription loop-mediated isothermal amplification (RT-LAMP) for multiplex target gene amplification, and the resultant amplicons were analyzed on the immunochromatographic strip (ICS) for subtyping influenza A virus. Through the optimized primer design, reaction temperature and time, and concentration of enzymes (Bst DNA polymerase and AMV reverse transcriptase) and dNTP, the HA (H1, H3, and H5 gene) and conserved M gene were amplified. The ICS contains two test lines in addition to a control line in order to detect the presence of the HA and M gene, thereby informing us of influenza virus A type as well as its subtype (H1N1, H3N2, and H5N1). The combination of the multiplex RT-LAMP with the ICS could be complete in 40 min and the pathotyping and subtyping of influenza A virus were performed even with 10 copies of viral RNA templates. Moreover, the subtyping of clinical samples, which were obtained from patients infected by influenza A virus was successfully confirmed using the multiplex RT-LAMP and ICS techniques, showing great feasibility of our methodology for real sample analysis with high speed, simplicity and sensitivity. Elsevier B.V. 2015-01-01 2014-10-16 /pmc/articles/PMC7094724/ /pubmed/25467501 http://dx.doi.org/10.1016/j.aca.2014.10.020 Text en Copyright © 2014 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Jung, Jae Hwan
Oh, Seung Jun
Kim, Yong Tae
Kim, So Yeon
Kim, Won-Jung
Jung, Jaean
Seo, Tae Seok
Combination of multiplex reverse-transcription loop-mediated isothermal amplification with an immunochromatographic strip for subtyping influenza A virus
title Combination of multiplex reverse-transcription loop-mediated isothermal amplification with an immunochromatographic strip for subtyping influenza A virus
title_full Combination of multiplex reverse-transcription loop-mediated isothermal amplification with an immunochromatographic strip for subtyping influenza A virus
title_fullStr Combination of multiplex reverse-transcription loop-mediated isothermal amplification with an immunochromatographic strip for subtyping influenza A virus
title_full_unstemmed Combination of multiplex reverse-transcription loop-mediated isothermal amplification with an immunochromatographic strip for subtyping influenza A virus
title_short Combination of multiplex reverse-transcription loop-mediated isothermal amplification with an immunochromatographic strip for subtyping influenza A virus
title_sort combination of multiplex reverse-transcription loop-mediated isothermal amplification with an immunochromatographic strip for subtyping influenza a virus
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7094724/
https://www.ncbi.nlm.nih.gov/pubmed/25467501
http://dx.doi.org/10.1016/j.aca.2014.10.020
work_keys_str_mv AT jungjaehwan combinationofmultiplexreversetranscriptionloopmediatedisothermalamplificationwithanimmunochromatographicstripforsubtypinginfluenzaavirus
AT ohseungjun combinationofmultiplexreversetranscriptionloopmediatedisothermalamplificationwithanimmunochromatographicstripforsubtypinginfluenzaavirus
AT kimyongtae combinationofmultiplexreversetranscriptionloopmediatedisothermalamplificationwithanimmunochromatographicstripforsubtypinginfluenzaavirus
AT kimsoyeon combinationofmultiplexreversetranscriptionloopmediatedisothermalamplificationwithanimmunochromatographicstripforsubtypinginfluenzaavirus
AT kimwonjung combinationofmultiplexreversetranscriptionloopmediatedisothermalamplificationwithanimmunochromatographicstripforsubtypinginfluenzaavirus
AT jungjaean combinationofmultiplexreversetranscriptionloopmediatedisothermalamplificationwithanimmunochromatographicstripforsubtypinginfluenzaavirus
AT seotaeseok combinationofmultiplexreversetranscriptionloopmediatedisothermalamplificationwithanimmunochromatographicstripforsubtypinginfluenzaavirus