Cargando…

Effects of Daily Activities and Position on Kinematics and Contact Mechanics of Dual Mobility Hip Implant

Dual mobility hip implants have been widely introduced to overcome dislocation in recent years. However, the potential influence of different gaits on kinematics and contact mechanics for dual mobility hip implants is still unclear. Furthermore, a large range of motion coupling with the implant posi...

Descripción completa

Detalles Bibliográficos
Autores principales: Gao, Yongchang, Zhao, Xin, Chen, Shibin, Zhang, Jing, Chen, Zhenxian, Jin, Zhongmin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7097768/
https://www.ncbi.nlm.nih.gov/pubmed/32257086
http://dx.doi.org/10.1155/2020/8103523
_version_ 1783511051235491840
author Gao, Yongchang
Zhao, Xin
Chen, Shibin
Zhang, Jing
Chen, Zhenxian
Jin, Zhongmin
author_facet Gao, Yongchang
Zhao, Xin
Chen, Shibin
Zhang, Jing
Chen, Zhenxian
Jin, Zhongmin
author_sort Gao, Yongchang
collection PubMed
description Dual mobility hip implants have been widely introduced to overcome dislocation in recent years. However, the potential influence of different gaits on kinematics and contact mechanics for dual mobility hip implants is still unclear. Furthermore, a large range of motion coupling with the implant position, especially high inclination or anteversion angle, may result in poor kinematics and contact mechanics. A previously developed dynamic finite element method was adopted in this study to examine the kinematics and corresponding stability of dual mobility hip implants under different gaits coupling with different inclinations or anteversion angles. The results showed only inner relative sliding under knee-bending for dual mobility hip implants under moderate inclination and anteversion angles, whereas an anteversion angle of 25° induced both impingement and consequent relative sliding of the outer articulation. However, the impingement (between the stem neck and the liner inner rim) indeed happened under stair-climbing and sitting-down/stand-up as well as combined movements when inclination and anteversion angles were set as 45° and 0°, respectively, and this finally led to relative sliding at the outer articulation. A high inclination angle did not worsen both the impingement and related outer sliding compared to modest inclination and anteversion angles of the liner, but a high anteversion angle prolonged the period of both the impingement and the outer relative sliding. The extreme motions and high anteversion angles are hardly inevitable, and they indeed lead to motions at both articulations for dual mobility hip implants.
format Online
Article
Text
id pubmed-7097768
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-70977682020-04-03 Effects of Daily Activities and Position on Kinematics and Contact Mechanics of Dual Mobility Hip Implant Gao, Yongchang Zhao, Xin Chen, Shibin Zhang, Jing Chen, Zhenxian Jin, Zhongmin J Healthc Eng Research Article Dual mobility hip implants have been widely introduced to overcome dislocation in recent years. However, the potential influence of different gaits on kinematics and contact mechanics for dual mobility hip implants is still unclear. Furthermore, a large range of motion coupling with the implant position, especially high inclination or anteversion angle, may result in poor kinematics and contact mechanics. A previously developed dynamic finite element method was adopted in this study to examine the kinematics and corresponding stability of dual mobility hip implants under different gaits coupling with different inclinations or anteversion angles. The results showed only inner relative sliding under knee-bending for dual mobility hip implants under moderate inclination and anteversion angles, whereas an anteversion angle of 25° induced both impingement and consequent relative sliding of the outer articulation. However, the impingement (between the stem neck and the liner inner rim) indeed happened under stair-climbing and sitting-down/stand-up as well as combined movements when inclination and anteversion angles were set as 45° and 0°, respectively, and this finally led to relative sliding at the outer articulation. A high inclination angle did not worsen both the impingement and related outer sliding compared to modest inclination and anteversion angles of the liner, but a high anteversion angle prolonged the period of both the impingement and the outer relative sliding. The extreme motions and high anteversion angles are hardly inevitable, and they indeed lead to motions at both articulations for dual mobility hip implants. Hindawi 2020-03-14 /pmc/articles/PMC7097768/ /pubmed/32257086 http://dx.doi.org/10.1155/2020/8103523 Text en Copyright © 2020 Yongchang Gao et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Gao, Yongchang
Zhao, Xin
Chen, Shibin
Zhang, Jing
Chen, Zhenxian
Jin, Zhongmin
Effects of Daily Activities and Position on Kinematics and Contact Mechanics of Dual Mobility Hip Implant
title Effects of Daily Activities and Position on Kinematics and Contact Mechanics of Dual Mobility Hip Implant
title_full Effects of Daily Activities and Position on Kinematics and Contact Mechanics of Dual Mobility Hip Implant
title_fullStr Effects of Daily Activities and Position on Kinematics and Contact Mechanics of Dual Mobility Hip Implant
title_full_unstemmed Effects of Daily Activities and Position on Kinematics and Contact Mechanics of Dual Mobility Hip Implant
title_short Effects of Daily Activities and Position on Kinematics and Contact Mechanics of Dual Mobility Hip Implant
title_sort effects of daily activities and position on kinematics and contact mechanics of dual mobility hip implant
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7097768/
https://www.ncbi.nlm.nih.gov/pubmed/32257086
http://dx.doi.org/10.1155/2020/8103523
work_keys_str_mv AT gaoyongchang effectsofdailyactivitiesandpositiononkinematicsandcontactmechanicsofdualmobilityhipimplant
AT zhaoxin effectsofdailyactivitiesandpositiononkinematicsandcontactmechanicsofdualmobilityhipimplant
AT chenshibin effectsofdailyactivitiesandpositiononkinematicsandcontactmechanicsofdualmobilityhipimplant
AT zhangjing effectsofdailyactivitiesandpositiononkinematicsandcontactmechanicsofdualmobilityhipimplant
AT chenzhenxian effectsofdailyactivitiesandpositiononkinematicsandcontactmechanicsofdualmobilityhipimplant
AT jinzhongmin effectsofdailyactivitiesandpositiononkinematicsandcontactmechanicsofdualmobilityhipimplant