Cargando…
Biomechanics and Mechanism of Action of Indirect Lumbar Decompression and the Evolution of a Stand-alone Spinous Process Spacer
OBJECTIVE: Objective Interspinous process spacers are used in the treatment of lumbar spinal stenosis by preventing extension at the implanted level and reducing claudication, which is a common symptom of lumbar spinal stenosis. This review assessed the current safety and performance of lumbar spina...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7101165/ https://www.ncbi.nlm.nih.gov/pubmed/31808533 http://dx.doi.org/10.1093/pm/pnz129 |
_version_ | 1783511561794486272 |
---|---|
author | Falowski, Steven M Sayed, Dawood Deer, Timothy R Brescacin, Dane Liang, Kevin |
author_facet | Falowski, Steven M Sayed, Dawood Deer, Timothy R Brescacin, Dane Liang, Kevin |
author_sort | Falowski, Steven M |
collection | PubMed |
description | OBJECTIVE: Objective Interspinous process spacers are used in the treatment of lumbar spinal stenosis by preventing extension at the implanted level and reducing claudication, which is a common symptom of lumbar spinal stenosis. This review assessed the current safety and performance of lumbar spinal stenosis treatments and the biomechanical effects of spinal position, range of motion, and the use of interspinous process spacers. METHOD: Method EMBASE and PubMed were searched to find studies reporting on the safety and performance of nonsurgical treatment, including physical therapy and pharmacological treatment, and surgical treatment, including direct and indirect lumbar decompression treatment. Results were supplemented with manual searches to include studies reporting on the use of interspinous process spacers and the review of biomechanical testing performed on the Superion device. RESULTS: Results The effects of spinal position in extension and flexion have been shown to have an impact in the variation in dimensions of the spinal canal and foramina areas. Overall studies have shown that spinal positions from flexion to extension reduce the spinal canal and foramina dimensions and increase ligamentum flavum thickness. Biomechanical test data have shown that the Superion device resists extension and reduces angular movement at the implantation level and provides significant segmental stability. CONCLUSIONS: Conclusions Superion interspinous lumbar decompression is a minimally invasive, low-risk procedure for the treatment of lumbar spinal stenosis, which has been shown to have a low safety profile by maintaining sagittal alignment, limiting the potential for device dislodgment or migration, and to preserve mobility and structural elements. |
format | Online Article Text |
id | pubmed-7101165 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-71011652020-04-02 Biomechanics and Mechanism of Action of Indirect Lumbar Decompression and the Evolution of a Stand-alone Spinous Process Spacer Falowski, Steven M Sayed, Dawood Deer, Timothy R Brescacin, Dane Liang, Kevin Pain Med Review Articles OBJECTIVE: Objective Interspinous process spacers are used in the treatment of lumbar spinal stenosis by preventing extension at the implanted level and reducing claudication, which is a common symptom of lumbar spinal stenosis. This review assessed the current safety and performance of lumbar spinal stenosis treatments and the biomechanical effects of spinal position, range of motion, and the use of interspinous process spacers. METHOD: Method EMBASE and PubMed were searched to find studies reporting on the safety and performance of nonsurgical treatment, including physical therapy and pharmacological treatment, and surgical treatment, including direct and indirect lumbar decompression treatment. Results were supplemented with manual searches to include studies reporting on the use of interspinous process spacers and the review of biomechanical testing performed on the Superion device. RESULTS: Results The effects of spinal position in extension and flexion have been shown to have an impact in the variation in dimensions of the spinal canal and foramina areas. Overall studies have shown that spinal positions from flexion to extension reduce the spinal canal and foramina dimensions and increase ligamentum flavum thickness. Biomechanical test data have shown that the Superion device resists extension and reduces angular movement at the implantation level and provides significant segmental stability. CONCLUSIONS: Conclusions Superion interspinous lumbar decompression is a minimally invasive, low-risk procedure for the treatment of lumbar spinal stenosis, which has been shown to have a low safety profile by maintaining sagittal alignment, limiting the potential for device dislodgment or migration, and to preserve mobility and structural elements. Oxford University Press 2019-12 2019-12-06 /pmc/articles/PMC7101165/ /pubmed/31808533 http://dx.doi.org/10.1093/pm/pnz129 Text en © The Author(s) 2019. Published by Oxford University Press on behalf of the American Academy of Pain Medicine. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Review Articles Falowski, Steven M Sayed, Dawood Deer, Timothy R Brescacin, Dane Liang, Kevin Biomechanics and Mechanism of Action of Indirect Lumbar Decompression and the Evolution of a Stand-alone Spinous Process Spacer |
title | Biomechanics and Mechanism of Action of Indirect Lumbar Decompression and the Evolution of a Stand-alone Spinous Process Spacer |
title_full | Biomechanics and Mechanism of Action of Indirect Lumbar Decompression and the Evolution of a Stand-alone Spinous Process Spacer |
title_fullStr | Biomechanics and Mechanism of Action of Indirect Lumbar Decompression and the Evolution of a Stand-alone Spinous Process Spacer |
title_full_unstemmed | Biomechanics and Mechanism of Action of Indirect Lumbar Decompression and the Evolution of a Stand-alone Spinous Process Spacer |
title_short | Biomechanics and Mechanism of Action of Indirect Lumbar Decompression and the Evolution of a Stand-alone Spinous Process Spacer |
title_sort | biomechanics and mechanism of action of indirect lumbar decompression and the evolution of a stand-alone spinous process spacer |
topic | Review Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7101165/ https://www.ncbi.nlm.nih.gov/pubmed/31808533 http://dx.doi.org/10.1093/pm/pnz129 |
work_keys_str_mv | AT falowskistevenm biomechanicsandmechanismofactionofindirectlumbardecompressionandtheevolutionofastandalonespinousprocessspacer AT sayeddawood biomechanicsandmechanismofactionofindirectlumbardecompressionandtheevolutionofastandalonespinousprocessspacer AT deertimothyr biomechanicsandmechanismofactionofindirectlumbardecompressionandtheevolutionofastandalonespinousprocessspacer AT brescacindane biomechanicsandmechanismofactionofindirectlumbardecompressionandtheevolutionofastandalonespinousprocessspacer AT liangkevin biomechanicsandmechanismofactionofindirectlumbardecompressionandtheevolutionofastandalonespinousprocessspacer |