Cargando…

Evaluation of new Corvis ST parameters in normal, Post-LASIK, Post-LASIK keratectasia and keratoconus eyes

The aim of this study was to evaluate the distribution of new Corneal Visualisation Scheimpflug Technology (Corvis ST) parameters in normal, Post-laser in situ keratomileusis (LASIK), Post-LASIK keratectasia (KE) and keratoconus (KC) eyes, and explore the diagnostic ability of these parameters in di...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Kaili, Xu, Liyan, Fan, Qi, Gu, Yuwei, Song, Peng, Zhang, Bo, Zhao, Dongqing, Pang, Chenjiu, Ren, Shengwei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7105482/
https://www.ncbi.nlm.nih.gov/pubmed/32231236
http://dx.doi.org/10.1038/s41598-020-62825-y
_version_ 1783512411847786496
author Yang, Kaili
Xu, Liyan
Fan, Qi
Gu, Yuwei
Song, Peng
Zhang, Bo
Zhao, Dongqing
Pang, Chenjiu
Ren, Shengwei
author_facet Yang, Kaili
Xu, Liyan
Fan, Qi
Gu, Yuwei
Song, Peng
Zhang, Bo
Zhao, Dongqing
Pang, Chenjiu
Ren, Shengwei
author_sort Yang, Kaili
collection PubMed
description The aim of this study was to evaluate the distribution of new Corneal Visualisation Scheimpflug Technology (Corvis ST) parameters in normal, Post-laser in situ keratomileusis (LASIK), Post-LASIK keratectasia (KE) and keratoconus (KC) eyes, and explore the diagnostic ability of these parameters in distinguishing KE from LASIK eyes. Twenty-three normal eyes, 23 LASIK eyes, 23 KE eyes and 23 KC eyes were recruited in this study. The following new Corvis ST parameters were measured: Max Inverse Radius, deformation amplitude (DA) Ratio Max [2 mm], Pachy Slope, DA Ratio Max [1 mm], Ambrosio’s relational thickness horizontal (ARTh), Integrated Radius, stiffness parameter at first applanation (SP-A1) and Corvis biomechanical index (CBI). The general linear model, linear regression model, relation analysis and receiver operating characteristic (ROC) curve were performed. The Max Inverse Radius, DA Ratio Max [2 mm], Pachy Slope, DA Ratio Max [1 mm], Integrated Radius and CBI in LASIK eyes, KE eyes and KC eyes were higher than in normal eyes, while the ARTh and SP-A1 parameters were lower than in normal eyes. The KE eyes had higher Max Inverse Radius, DA Ratio Max [2 mm], Pachy Slope, DA Ratio Max [1 mm], Integrated Radius, and lower SP-A1 value than LASIK eyes (all P < 0.05). The central corneal thickness was related to the Pachy Slope (r = −0.485), ARTh (r = −0.766), SP-A1 (r = 0.618) in KE eyes (all P < 0.05). The area under the ROC curve of Integrated Radius, Max Inverse Radius, DA Ratio Max [2 mm] and SP-A1 were above 0.800 in identifying KE from LASIK eyes. Thus, the new Corvis ST parameters were different between LASIK and KE eyes, suggesting that they might be helpful in distinguishing KE eyes from LASIK eyes. However, a further multi-center and large sample study is necessary to confirm these findings.
format Online
Article
Text
id pubmed-7105482
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-71054822020-04-06 Evaluation of new Corvis ST parameters in normal, Post-LASIK, Post-LASIK keratectasia and keratoconus eyes Yang, Kaili Xu, Liyan Fan, Qi Gu, Yuwei Song, Peng Zhang, Bo Zhao, Dongqing Pang, Chenjiu Ren, Shengwei Sci Rep Article The aim of this study was to evaluate the distribution of new Corneal Visualisation Scheimpflug Technology (Corvis ST) parameters in normal, Post-laser in situ keratomileusis (LASIK), Post-LASIK keratectasia (KE) and keratoconus (KC) eyes, and explore the diagnostic ability of these parameters in distinguishing KE from LASIK eyes. Twenty-three normal eyes, 23 LASIK eyes, 23 KE eyes and 23 KC eyes were recruited in this study. The following new Corvis ST parameters were measured: Max Inverse Radius, deformation amplitude (DA) Ratio Max [2 mm], Pachy Slope, DA Ratio Max [1 mm], Ambrosio’s relational thickness horizontal (ARTh), Integrated Radius, stiffness parameter at first applanation (SP-A1) and Corvis biomechanical index (CBI). The general linear model, linear regression model, relation analysis and receiver operating characteristic (ROC) curve were performed. The Max Inverse Radius, DA Ratio Max [2 mm], Pachy Slope, DA Ratio Max [1 mm], Integrated Radius and CBI in LASIK eyes, KE eyes and KC eyes were higher than in normal eyes, while the ARTh and SP-A1 parameters were lower than in normal eyes. The KE eyes had higher Max Inverse Radius, DA Ratio Max [2 mm], Pachy Slope, DA Ratio Max [1 mm], Integrated Radius, and lower SP-A1 value than LASIK eyes (all P < 0.05). The central corneal thickness was related to the Pachy Slope (r = −0.485), ARTh (r = −0.766), SP-A1 (r = 0.618) in KE eyes (all P < 0.05). The area under the ROC curve of Integrated Radius, Max Inverse Radius, DA Ratio Max [2 mm] and SP-A1 were above 0.800 in identifying KE from LASIK eyes. Thus, the new Corvis ST parameters were different between LASIK and KE eyes, suggesting that they might be helpful in distinguishing KE eyes from LASIK eyes. However, a further multi-center and large sample study is necessary to confirm these findings. Nature Publishing Group UK 2020-03-30 /pmc/articles/PMC7105482/ /pubmed/32231236 http://dx.doi.org/10.1038/s41598-020-62825-y Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Yang, Kaili
Xu, Liyan
Fan, Qi
Gu, Yuwei
Song, Peng
Zhang, Bo
Zhao, Dongqing
Pang, Chenjiu
Ren, Shengwei
Evaluation of new Corvis ST parameters in normal, Post-LASIK, Post-LASIK keratectasia and keratoconus eyes
title Evaluation of new Corvis ST parameters in normal, Post-LASIK, Post-LASIK keratectasia and keratoconus eyes
title_full Evaluation of new Corvis ST parameters in normal, Post-LASIK, Post-LASIK keratectasia and keratoconus eyes
title_fullStr Evaluation of new Corvis ST parameters in normal, Post-LASIK, Post-LASIK keratectasia and keratoconus eyes
title_full_unstemmed Evaluation of new Corvis ST parameters in normal, Post-LASIK, Post-LASIK keratectasia and keratoconus eyes
title_short Evaluation of new Corvis ST parameters in normal, Post-LASIK, Post-LASIK keratectasia and keratoconus eyes
title_sort evaluation of new corvis st parameters in normal, post-lasik, post-lasik keratectasia and keratoconus eyes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7105482/
https://www.ncbi.nlm.nih.gov/pubmed/32231236
http://dx.doi.org/10.1038/s41598-020-62825-y
work_keys_str_mv AT yangkaili evaluationofnewcorvisstparametersinnormalpostlasikpostlasikkeratectasiaandkeratoconuseyes
AT xuliyan evaluationofnewcorvisstparametersinnormalpostlasikpostlasikkeratectasiaandkeratoconuseyes
AT fanqi evaluationofnewcorvisstparametersinnormalpostlasikpostlasikkeratectasiaandkeratoconuseyes
AT guyuwei evaluationofnewcorvisstparametersinnormalpostlasikpostlasikkeratectasiaandkeratoconuseyes
AT songpeng evaluationofnewcorvisstparametersinnormalpostlasikpostlasikkeratectasiaandkeratoconuseyes
AT zhangbo evaluationofnewcorvisstparametersinnormalpostlasikpostlasikkeratectasiaandkeratoconuseyes
AT zhaodongqing evaluationofnewcorvisstparametersinnormalpostlasikpostlasikkeratectasiaandkeratoconuseyes
AT pangchenjiu evaluationofnewcorvisstparametersinnormalpostlasikpostlasikkeratectasiaandkeratoconuseyes
AT renshengwei evaluationofnewcorvisstparametersinnormalpostlasikpostlasikkeratectasiaandkeratoconuseyes