Cargando…

Clinical evaluation of real-time PCR assays for rapid diagnosis of SARS coronavirus during outbreak and post-epidemic periods

BACKGROUND: The protocols of WHO network laboratories facilitated development of rapid diagnosis for SARS coronavirus (CoV) using reverse transcription (RT)-PCR assays. However, several reports have shown that conventional and real-time PCR assays were very specific for SARS CoV but lack sensitivity...

Descripción completa

Detalles Bibliográficos
Autores principales: Yam, W.C., Chan, K.H., Chow, K.H., Poon, L.L.M., Lam, H.Y., Yuen, K.Y., Seto, W.H., Peiris, J.S.M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier B.V. 2005
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7108323/
https://www.ncbi.nlm.nih.gov/pubmed/15797361
http://dx.doi.org/10.1016/j.jcv.2004.09.029
Descripción
Sumario:BACKGROUND: The protocols of WHO network laboratories facilitated development of rapid diagnosis for SARS coronavirus (CoV) using reverse transcription (RT)-PCR assays. However, several reports have shown that conventional and real-time PCR assays were very specific for SARS CoV but lack sensitivity depending on the assay, specimen, and time course of disease. OBJECTIVE: To evaluate an automatic nucleic acid extraction system and two standardized real-time PCR assays for rapid diagnosis of SARS CoV during outbreak and post-epidemic periods in Hong Kong. STUDY DESIGN: Specimens from clinically suspected SARS patients collected during outbreak and post-epidemic periods were tested by an automatic nucleic acid extraction system followed by our first generation conventional RT-PCR and two standardized real-time PCR assays (Artus GmbH, Germany and Roche Diagnostics, Germany). Paired serum samples were assayed for increasing titer against SARS CoV. RESULTS: In the SARS epidemic, Artus and Roche PCR assays exhibited sensitivities of 87% and 85% for respiratory specimens (n = 64), 91% and 88% for stool (n = 44), and 82% for urine (n = 29). A specificity of 100% was exhibited by both PCR assays except Artus attained only a 92% specificity for stool. For post-epidemic period, no SARS CoV was identified among 56 respiratory specimens by all PCR assays. Inhibitors to PCR assays were detected at an average rate of 7–8% among 202 clinical specimens. CONCLUSION: This study highlights the high throughput and performance of automatic RNA extraction in coordination with standardized real-time PCR assays suitable for large-scale routine diagnosis in case of future SARS epidemic. As no SARS CoV was detected among specimens collected during post-epidemic period, the positive predictive value of real-time PCR assays for detection of SARS CoV during low epidemic requires further evaluation.