Cargando…

Dose assessment in dental cone-beam computed tomography: Comparison of optically stimulated luminescence dosimetry with Monte Carlo method

The variety of cone-beam computed tomography (CBCT) machines and their applications has rapidly increased in recent years, making the dose evaluation of individual devices an important issue. Patient doses from CBCT were assessed with two different methods: optically stimulated luminescence dosimete...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Chena, Yoon, Jeongmin, Han, Sang-Sun, Na, Ji Yeon, Lee, Jeong-Hee, Kim, Young Hyun, Hwang, Jae Joon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7108699/
https://www.ncbi.nlm.nih.gov/pubmed/32231373
http://dx.doi.org/10.1371/journal.pone.0219103
_version_ 1783512826912964608
author Lee, Chena
Yoon, Jeongmin
Han, Sang-Sun
Na, Ji Yeon
Lee, Jeong-Hee
Kim, Young Hyun
Hwang, Jae Joon
author_facet Lee, Chena
Yoon, Jeongmin
Han, Sang-Sun
Na, Ji Yeon
Lee, Jeong-Hee
Kim, Young Hyun
Hwang, Jae Joon
author_sort Lee, Chena
collection PubMed
description The variety of cone-beam computed tomography (CBCT) machines and their applications has rapidly increased in recent years, making the dose evaluation of individual devices an important issue. Patient doses from CBCT were assessed with two different methods: optically stimulated luminescence dosimeter (OSLD) measurements and Monte Carlo (MC) simulations, in four different examination modes. Based on an analysis of the measurement process and the obtained values, a recommendation is made regarding which method is more practical and efficient for acquiring the effective dose of CBCT. Twenty-two OSLDs were calibrated and equipped in human phantoms of head and neck organs. They were exposed to radiation from two CBCT units—CS9300 (Carestream Dental LLC, Atlanta, Georgia) and RAYSCAN α+ (Ray Co. Ltd, Hwaseong-si, Korea)—using two different examination modes. The dose recorded using the OSLDs was used to calculate the organ dose and the effective dose for each unit in each examination mode. These values were also calculated using MC software, PCXMC (STUK, Helsinki, Finland). The organ doses and effective doses obtained using both methods were compared for each examination mode of the individual units. The OSLD-measured effective dose value was higher than that obtained using the MC method for each examination mode, except the dual jaw mode of CS9300. The percent difference of the effective dose between the two methods ranged from 4.0% to 14.3%. The dose difference between the methods decreased as the field of view became smaller. The organ dose values varied according to the method, although the overall trend was similar for both methods. The organs showing high doses were mostly consistent for both methods. In this study, the effective dose obtained by OSLD measurements and MC simulations were compared, and both methods were described in detail. As a relatively efficient and easy-to-perform method, we cautiously suggest using MC simulations for dose evaluations in the future.
format Online
Article
Text
id pubmed-7108699
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-71086992020-04-03 Dose assessment in dental cone-beam computed tomography: Comparison of optically stimulated luminescence dosimetry with Monte Carlo method Lee, Chena Yoon, Jeongmin Han, Sang-Sun Na, Ji Yeon Lee, Jeong-Hee Kim, Young Hyun Hwang, Jae Joon PLoS One Research Article The variety of cone-beam computed tomography (CBCT) machines and their applications has rapidly increased in recent years, making the dose evaluation of individual devices an important issue. Patient doses from CBCT were assessed with two different methods: optically stimulated luminescence dosimeter (OSLD) measurements and Monte Carlo (MC) simulations, in four different examination modes. Based on an analysis of the measurement process and the obtained values, a recommendation is made regarding which method is more practical and efficient for acquiring the effective dose of CBCT. Twenty-two OSLDs were calibrated and equipped in human phantoms of head and neck organs. They were exposed to radiation from two CBCT units—CS9300 (Carestream Dental LLC, Atlanta, Georgia) and RAYSCAN α+ (Ray Co. Ltd, Hwaseong-si, Korea)—using two different examination modes. The dose recorded using the OSLDs was used to calculate the organ dose and the effective dose for each unit in each examination mode. These values were also calculated using MC software, PCXMC (STUK, Helsinki, Finland). The organ doses and effective doses obtained using both methods were compared for each examination mode of the individual units. The OSLD-measured effective dose value was higher than that obtained using the MC method for each examination mode, except the dual jaw mode of CS9300. The percent difference of the effective dose between the two methods ranged from 4.0% to 14.3%. The dose difference between the methods decreased as the field of view became smaller. The organ dose values varied according to the method, although the overall trend was similar for both methods. The organs showing high doses were mostly consistent for both methods. In this study, the effective dose obtained by OSLD measurements and MC simulations were compared, and both methods were described in detail. As a relatively efficient and easy-to-perform method, we cautiously suggest using MC simulations for dose evaluations in the future. Public Library of Science 2020-03-31 /pmc/articles/PMC7108699/ /pubmed/32231373 http://dx.doi.org/10.1371/journal.pone.0219103 Text en © 2020 Lee et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Lee, Chena
Yoon, Jeongmin
Han, Sang-Sun
Na, Ji Yeon
Lee, Jeong-Hee
Kim, Young Hyun
Hwang, Jae Joon
Dose assessment in dental cone-beam computed tomography: Comparison of optically stimulated luminescence dosimetry with Monte Carlo method
title Dose assessment in dental cone-beam computed tomography: Comparison of optically stimulated luminescence dosimetry with Monte Carlo method
title_full Dose assessment in dental cone-beam computed tomography: Comparison of optically stimulated luminescence dosimetry with Monte Carlo method
title_fullStr Dose assessment in dental cone-beam computed tomography: Comparison of optically stimulated luminescence dosimetry with Monte Carlo method
title_full_unstemmed Dose assessment in dental cone-beam computed tomography: Comparison of optically stimulated luminescence dosimetry with Monte Carlo method
title_short Dose assessment in dental cone-beam computed tomography: Comparison of optically stimulated luminescence dosimetry with Monte Carlo method
title_sort dose assessment in dental cone-beam computed tomography: comparison of optically stimulated luminescence dosimetry with monte carlo method
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7108699/
https://www.ncbi.nlm.nih.gov/pubmed/32231373
http://dx.doi.org/10.1371/journal.pone.0219103
work_keys_str_mv AT leechena doseassessmentindentalconebeamcomputedtomographycomparisonofopticallystimulatedluminescencedosimetrywithmontecarlomethod
AT yoonjeongmin doseassessmentindentalconebeamcomputedtomographycomparisonofopticallystimulatedluminescencedosimetrywithmontecarlomethod
AT hansangsun doseassessmentindentalconebeamcomputedtomographycomparisonofopticallystimulatedluminescencedosimetrywithmontecarlomethod
AT najiyeon doseassessmentindentalconebeamcomputedtomographycomparisonofopticallystimulatedluminescencedosimetrywithmontecarlomethod
AT leejeonghee doseassessmentindentalconebeamcomputedtomographycomparisonofopticallystimulatedluminescencedosimetrywithmontecarlomethod
AT kimyounghyun doseassessmentindentalconebeamcomputedtomographycomparisonofopticallystimulatedluminescencedosimetrywithmontecarlomethod
AT hwangjaejoon doseassessmentindentalconebeamcomputedtomographycomparisonofopticallystimulatedluminescencedosimetrywithmontecarlomethod