Cargando…

Laparoscopic Removal of Modified Vertical Uterine Compression Sutures due to Postoperative Focal Pain

Previously we reported laparoscopic removal of compression sutures due to uterine ischemia and related pain, which has two of the difficult aspects: (1) maneuvering the curved needle to perform compression suturing in the narrow surgical field, and (2) distinguishing between the threads of the cesar...

Descripción completa

Detalles Bibliográficos
Autores principales: Suzuki, Toshifumi, Takeda, Jun, Jinushi, Makoto, Seyama, Rie, Maruyama, Yojiro, Makino, Shintaro, Kitade, Mari, Itakura, Atsuo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Medical Publishers 2020
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7108947/
https://www.ncbi.nlm.nih.gov/pubmed/32258412
http://dx.doi.org/10.1055/s-0040-1708865
_version_ 1783512860471590912
author Suzuki, Toshifumi
Takeda, Jun
Jinushi, Makoto
Seyama, Rie
Maruyama, Yojiro
Makino, Shintaro
Kitade, Mari
Itakura, Atsuo
author_facet Suzuki, Toshifumi
Takeda, Jun
Jinushi, Makoto
Seyama, Rie
Maruyama, Yojiro
Makino, Shintaro
Kitade, Mari
Itakura, Atsuo
author_sort Suzuki, Toshifumi
collection PubMed
description Previously we reported laparoscopic removal of compression sutures due to uterine ischemia and related pain, which has two of the difficult aspects: (1) maneuvering the curved needle to perform compression suturing in the narrow surgical field, and (2) distinguishing between the threads of the cesarean section wound sutures versus the vertical compression sutures during removal, as the threads are the same white color. We performed vertical compression sutures for intrapartum hemorrhage with total placental previa, and modified both the needle type and the color of the thread used for uterine compression sutures during cesarean section. After the operation, we performed successful laparoscopic removal of compression sutures for postoperative focal pain. Changing the needle type and color helped to perform operations. The present case supports the concept that the laparoscopic removal of uterine compression suturing is useful for controlling pain in cases where general analgesics are ineffective.
format Online
Article
Text
id pubmed-7108947
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Thieme Medical Publishers
record_format MEDLINE/PubMed
spelling pubmed-71089472020-04-01 Laparoscopic Removal of Modified Vertical Uterine Compression Sutures due to Postoperative Focal Pain Suzuki, Toshifumi Takeda, Jun Jinushi, Makoto Seyama, Rie Maruyama, Yojiro Makino, Shintaro Kitade, Mari Itakura, Atsuo Surg J (N Y) Previously we reported laparoscopic removal of compression sutures due to uterine ischemia and related pain, which has two of the difficult aspects: (1) maneuvering the curved needle to perform compression suturing in the narrow surgical field, and (2) distinguishing between the threads of the cesarean section wound sutures versus the vertical compression sutures during removal, as the threads are the same white color. We performed vertical compression sutures for intrapartum hemorrhage with total placental previa, and modified both the needle type and the color of the thread used for uterine compression sutures during cesarean section. After the operation, we performed successful laparoscopic removal of compression sutures for postoperative focal pain. Changing the needle type and color helped to perform operations. The present case supports the concept that the laparoscopic removal of uterine compression suturing is useful for controlling pain in cases where general analgesics are ineffective. Thieme Medical Publishers 2020-03-31 /pmc/articles/PMC7108947/ /pubmed/32258412 http://dx.doi.org/10.1055/s-0040-1708865 Text en https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Suzuki, Toshifumi
Takeda, Jun
Jinushi, Makoto
Seyama, Rie
Maruyama, Yojiro
Makino, Shintaro
Kitade, Mari
Itakura, Atsuo
Laparoscopic Removal of Modified Vertical Uterine Compression Sutures due to Postoperative Focal Pain
title Laparoscopic Removal of Modified Vertical Uterine Compression Sutures due to Postoperative Focal Pain
title_full Laparoscopic Removal of Modified Vertical Uterine Compression Sutures due to Postoperative Focal Pain
title_fullStr Laparoscopic Removal of Modified Vertical Uterine Compression Sutures due to Postoperative Focal Pain
title_full_unstemmed Laparoscopic Removal of Modified Vertical Uterine Compression Sutures due to Postoperative Focal Pain
title_short Laparoscopic Removal of Modified Vertical Uterine Compression Sutures due to Postoperative Focal Pain
title_sort laparoscopic removal of modified vertical uterine compression sutures due to postoperative focal pain
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7108947/
https://www.ncbi.nlm.nih.gov/pubmed/32258412
http://dx.doi.org/10.1055/s-0040-1708865
work_keys_str_mv AT suzukitoshifumi laparoscopicremovalofmodifiedverticaluterinecompressionsuturesduetopostoperativefocalpain
AT takedajun laparoscopicremovalofmodifiedverticaluterinecompressionsuturesduetopostoperativefocalpain
AT jinushimakoto laparoscopicremovalofmodifiedverticaluterinecompressionsuturesduetopostoperativefocalpain
AT seyamarie laparoscopicremovalofmodifiedverticaluterinecompressionsuturesduetopostoperativefocalpain
AT maruyamayojiro laparoscopicremovalofmodifiedverticaluterinecompressionsuturesduetopostoperativefocalpain
AT makinoshintaro laparoscopicremovalofmodifiedverticaluterinecompressionsuturesduetopostoperativefocalpain
AT kitademari laparoscopicremovalofmodifiedverticaluterinecompressionsuturesduetopostoperativefocalpain
AT itakuraatsuo laparoscopicremovalofmodifiedverticaluterinecompressionsuturesduetopostoperativefocalpain