Cargando…

Association between intracortical microarchitecture and the compressive fatigue life of human bone: A pilot study

Many mechanical properties of cortical bone are largely governed by the underlying microarchitecture; however, the influence of microarchitecture on the fatigue life of bone is poorly understood. Furthermore, imaging-based studies investigating intracortical microarchitecture may expose bone samples...

Descripción completa

Detalles Bibliográficos
Autores principales: Loundagin, Lindsay L., Haider, Ifaz T., Cooper, David M.L., Edwards, W. Brent
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7110329/
https://www.ncbi.nlm.nih.gov/pubmed/32258250
http://dx.doi.org/10.1016/j.bonr.2020.100254
_version_ 1783513030591512576
author Loundagin, Lindsay L.
Haider, Ifaz T.
Cooper, David M.L.
Edwards, W. Brent
author_facet Loundagin, Lindsay L.
Haider, Ifaz T.
Cooper, David M.L.
Edwards, W. Brent
author_sort Loundagin, Lindsay L.
collection PubMed
description Many mechanical properties of cortical bone are largely governed by the underlying microarchitecture; however, the influence of microarchitecture on the fatigue life of bone is poorly understood. Furthermore, imaging-based studies investigating intracortical microarchitecture may expose bone samples to large doses of radiation that may compromise fatigue resistance. The purpose of this pilot study was to 1) investigate the relationship between intracortical microarchitecture and the fatigue life of human bone in compression and 2) examine the effects of synchrotron irradiation on fatigue life measurements. Cortical samples were prepared from the femoral and tibial shafts of three cadaveric donors. A subset of samples was imaged using synchrotron X-ray microCT to quantify microarchitecture, including porosity, canal diameter, lacunar density, lacunar volume, and lacunar orientation. A second group of control samples was not imaged and used only for mechanical testing. Fatigue life was quantified by cyclically loading both groups in zero-compression until failure. Increased porosity and larger canal diameter were both logarithmically related to a shorter fatigue life, whereas lacunar density demonstrated a positive linear relationship with fatigue life (r(2) = 45–73%, depending on measure). Irradiation from microCT scanning reduced fatigue life measurements by 91%, but relationships with microarchitecture measurements remained. Additional research is needed to support the findings of this pilot study and fully establish the relationship between intracortical microarchitecture and the compressive fatigue life of bone.
format Online
Article
Text
id pubmed-7110329
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-71103292020-04-03 Association between intracortical microarchitecture and the compressive fatigue life of human bone: A pilot study Loundagin, Lindsay L. Haider, Ifaz T. Cooper, David M.L. Edwards, W. Brent Bone Rep Article Many mechanical properties of cortical bone are largely governed by the underlying microarchitecture; however, the influence of microarchitecture on the fatigue life of bone is poorly understood. Furthermore, imaging-based studies investigating intracortical microarchitecture may expose bone samples to large doses of radiation that may compromise fatigue resistance. The purpose of this pilot study was to 1) investigate the relationship between intracortical microarchitecture and the fatigue life of human bone in compression and 2) examine the effects of synchrotron irradiation on fatigue life measurements. Cortical samples were prepared from the femoral and tibial shafts of three cadaveric donors. A subset of samples was imaged using synchrotron X-ray microCT to quantify microarchitecture, including porosity, canal diameter, lacunar density, lacunar volume, and lacunar orientation. A second group of control samples was not imaged and used only for mechanical testing. Fatigue life was quantified by cyclically loading both groups in zero-compression until failure. Increased porosity and larger canal diameter were both logarithmically related to a shorter fatigue life, whereas lacunar density demonstrated a positive linear relationship with fatigue life (r(2) = 45–73%, depending on measure). Irradiation from microCT scanning reduced fatigue life measurements by 91%, but relationships with microarchitecture measurements remained. Additional research is needed to support the findings of this pilot study and fully establish the relationship between intracortical microarchitecture and the compressive fatigue life of bone. Elsevier 2020-03-05 /pmc/articles/PMC7110329/ /pubmed/32258250 http://dx.doi.org/10.1016/j.bonr.2020.100254 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Loundagin, Lindsay L.
Haider, Ifaz T.
Cooper, David M.L.
Edwards, W. Brent
Association between intracortical microarchitecture and the compressive fatigue life of human bone: A pilot study
title Association between intracortical microarchitecture and the compressive fatigue life of human bone: A pilot study
title_full Association between intracortical microarchitecture and the compressive fatigue life of human bone: A pilot study
title_fullStr Association between intracortical microarchitecture and the compressive fatigue life of human bone: A pilot study
title_full_unstemmed Association between intracortical microarchitecture and the compressive fatigue life of human bone: A pilot study
title_short Association between intracortical microarchitecture and the compressive fatigue life of human bone: A pilot study
title_sort association between intracortical microarchitecture and the compressive fatigue life of human bone: a pilot study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7110329/
https://www.ncbi.nlm.nih.gov/pubmed/32258250
http://dx.doi.org/10.1016/j.bonr.2020.100254
work_keys_str_mv AT loundaginlindsayl associationbetweenintracorticalmicroarchitectureandthecompressivefatiguelifeofhumanboneapilotstudy
AT haiderifazt associationbetweenintracorticalmicroarchitectureandthecompressivefatiguelifeofhumanboneapilotstudy
AT cooperdavidml associationbetweenintracorticalmicroarchitectureandthecompressivefatiguelifeofhumanboneapilotstudy
AT edwardswbrent associationbetweenintracorticalmicroarchitectureandthecompressivefatiguelifeofhumanboneapilotstudy