Cargando…

Three-dimensional dose reconstruction-based pretreatment dosimetric verification in volumetric modulated arc therapy for prostate cancer

PURPOSE: We performed three-dimensional (3D) dose reconstruction-based pretreatment verification to evaluate gamma analysis acceptance criteria in volumetric modulated arc therapy (VMAT) for prostate cancer. MATERIALS AND METHODS: Pretreatment verification for 28 VMAT plans for prostate cancer was p...

Descripción completa

Detalles Bibliográficos
Autores principales: Jeong, Yuri, Oh, Jeong Geun, Kang, Jeong Ku, Moon, Sun Rock, Lee, Kang Kyoo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Radiation Oncology 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7113150/
https://www.ncbi.nlm.nih.gov/pubmed/32229810
http://dx.doi.org/10.3857/roj.2020.00066
_version_ 1783513607636516864
author Jeong, Yuri
Oh, Jeong Geun
Kang, Jeong Ku
Moon, Sun Rock
Lee, Kang Kyoo
author_facet Jeong, Yuri
Oh, Jeong Geun
Kang, Jeong Ku
Moon, Sun Rock
Lee, Kang Kyoo
author_sort Jeong, Yuri
collection PubMed
description PURPOSE: We performed three-dimensional (3D) dose reconstruction-based pretreatment verification to evaluate gamma analysis acceptance criteria in volumetric modulated arc therapy (VMAT) for prostate cancer. MATERIALS AND METHODS: Pretreatment verification for 28 VMAT plans for prostate cancer was performed using the COMPASS system with a dolphin detector. The 3D reconstructed dose distribution of the treatment planning system calculation (TC) was compared with that of COMPASS independent calculation (CC) and COMPASS reconstruction from the dolphin detector measurement (CR). Gamma results (gamma failure rate and average gamma value [GFR and γAvg]) and dose-volume histogram (DVH) deviations, 98%, 2% and mean dose-volume difference (DD(98%), DD(2%) and DD(mean)), were evaluated. Gamma analyses were performed with two acceptance criteria, 2%/2 mm and 3%/3 mm. RESULTS: The GFR in 2%/2 mm criteria were less than 8%, and those in 3%/3 mm criteria were less than 1% for all structures in comparisons between TC, CC, and CR. In the comparison between TC and CR, GFR and γAvg in 2%/2 mm criteria were significantly higher than those in 3%/3 mm criteria. The DVH deviations were within 2%, except for DD(mean) (%) for rectum and bladder. CONCLUSIONS: The 3%/3 mm criteria were not strict enough to identify any discrepancies between planned and measured doses, and DVH deviations were less than 2% in most parameters. Therefore, gamma criteria of 2%/2 mm and DVH related parameters could be a useful tool for pretreatment verification for VMAT in prostate cancer.
format Online
Article
Text
id pubmed-7113150
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Korean Society for Radiation Oncology
record_format MEDLINE/PubMed
spelling pubmed-71131502020-04-07 Three-dimensional dose reconstruction-based pretreatment dosimetric verification in volumetric modulated arc therapy for prostate cancer Jeong, Yuri Oh, Jeong Geun Kang, Jeong Ku Moon, Sun Rock Lee, Kang Kyoo Radiat Oncol J Original Article PURPOSE: We performed three-dimensional (3D) dose reconstruction-based pretreatment verification to evaluate gamma analysis acceptance criteria in volumetric modulated arc therapy (VMAT) for prostate cancer. MATERIALS AND METHODS: Pretreatment verification for 28 VMAT plans for prostate cancer was performed using the COMPASS system with a dolphin detector. The 3D reconstructed dose distribution of the treatment planning system calculation (TC) was compared with that of COMPASS independent calculation (CC) and COMPASS reconstruction from the dolphin detector measurement (CR). Gamma results (gamma failure rate and average gamma value [GFR and γAvg]) and dose-volume histogram (DVH) deviations, 98%, 2% and mean dose-volume difference (DD(98%), DD(2%) and DD(mean)), were evaluated. Gamma analyses were performed with two acceptance criteria, 2%/2 mm and 3%/3 mm. RESULTS: The GFR in 2%/2 mm criteria were less than 8%, and those in 3%/3 mm criteria were less than 1% for all structures in comparisons between TC, CC, and CR. In the comparison between TC and CR, GFR and γAvg in 2%/2 mm criteria were significantly higher than those in 3%/3 mm criteria. The DVH deviations were within 2%, except for DD(mean) (%) for rectum and bladder. CONCLUSIONS: The 3%/3 mm criteria were not strict enough to identify any discrepancies between planned and measured doses, and DVH deviations were less than 2% in most parameters. Therefore, gamma criteria of 2%/2 mm and DVH related parameters could be a useful tool for pretreatment verification for VMAT in prostate cancer. The Korean Society for Radiation Oncology 2020-03 2020-03-25 /pmc/articles/PMC7113150/ /pubmed/32229810 http://dx.doi.org/10.3857/roj.2020.00066 Text en Copyright © 2020 The Korean Society for Radiation Oncology This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Jeong, Yuri
Oh, Jeong Geun
Kang, Jeong Ku
Moon, Sun Rock
Lee, Kang Kyoo
Three-dimensional dose reconstruction-based pretreatment dosimetric verification in volumetric modulated arc therapy for prostate cancer
title Three-dimensional dose reconstruction-based pretreatment dosimetric verification in volumetric modulated arc therapy for prostate cancer
title_full Three-dimensional dose reconstruction-based pretreatment dosimetric verification in volumetric modulated arc therapy for prostate cancer
title_fullStr Three-dimensional dose reconstruction-based pretreatment dosimetric verification in volumetric modulated arc therapy for prostate cancer
title_full_unstemmed Three-dimensional dose reconstruction-based pretreatment dosimetric verification in volumetric modulated arc therapy for prostate cancer
title_short Three-dimensional dose reconstruction-based pretreatment dosimetric verification in volumetric modulated arc therapy for prostate cancer
title_sort three-dimensional dose reconstruction-based pretreatment dosimetric verification in volumetric modulated arc therapy for prostate cancer
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7113150/
https://www.ncbi.nlm.nih.gov/pubmed/32229810
http://dx.doi.org/10.3857/roj.2020.00066
work_keys_str_mv AT jeongyuri threedimensionaldosereconstructionbasedpretreatmentdosimetricverificationinvolumetricmodulatedarctherapyforprostatecancer
AT ohjeonggeun threedimensionaldosereconstructionbasedpretreatmentdosimetricverificationinvolumetricmodulatedarctherapyforprostatecancer
AT kangjeongku threedimensionaldosereconstructionbasedpretreatmentdosimetricverificationinvolumetricmodulatedarctherapyforprostatecancer
AT moonsunrock threedimensionaldosereconstructionbasedpretreatmentdosimetricverificationinvolumetricmodulatedarctherapyforprostatecancer
AT leekangkyoo threedimensionaldosereconstructionbasedpretreatmentdosimetricverificationinvolumetricmodulatedarctherapyforprostatecancer