Cargando…

Use of intraoperative ultrasonography for identification and management of pneumothorax caused by iatrogenic diaphragm defect: a case report and literature review

Transthoracic ultrasound has been widely accepted for the evaluation of many thoracic diseases, including pleural effusion, atelectasis, pneumothorax, and pneumonia with subpleural effusion. Application of ultrasonography for the diagnosis of pneumothorax is an effective and timely intraoperative te...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, Qiang, Wang, Beibei, Xu, Aijun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7113711/
https://www.ncbi.nlm.nih.gov/pubmed/31964200
http://dx.doi.org/10.1177/0300060519898048
_version_ 1783513731340173312
author Han, Qiang
Wang, Beibei
Xu, Aijun
author_facet Han, Qiang
Wang, Beibei
Xu, Aijun
author_sort Han, Qiang
collection PubMed
description Transthoracic ultrasound has been widely accepted for the evaluation of many thoracic diseases, including pleural effusion, atelectasis, pneumothorax, and pneumonia with subpleural effusion. Application of ultrasonography for the diagnosis of pneumothorax is an effective and timely intraoperative technique. We herein present a patient who developed pneumothorax following diaphragmatic injury during laparoscopic cholecystectomy. The pneumothorax was rapidly identified by bedside ultrasound. The compressed lung was successfully re-expanded using positive end-expiratory pressure (PEEP) ventilation under real-time ultrasound monitoring, and closed thoracic drainage was avoided. Therefore, the correct use of ultrasound can identify the adequate PEEP level that is able to promote resolution of pneumothorax induced by diaphragmatic injury.
format Online
Article
Text
id pubmed-7113711
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-71137112020-04-09 Use of intraoperative ultrasonography for identification and management of pneumothorax caused by iatrogenic diaphragm defect: a case report and literature review Han, Qiang Wang, Beibei Xu, Aijun J Int Med Res Case Report Transthoracic ultrasound has been widely accepted for the evaluation of many thoracic diseases, including pleural effusion, atelectasis, pneumothorax, and pneumonia with subpleural effusion. Application of ultrasonography for the diagnosis of pneumothorax is an effective and timely intraoperative technique. We herein present a patient who developed pneumothorax following diaphragmatic injury during laparoscopic cholecystectomy. The pneumothorax was rapidly identified by bedside ultrasound. The compressed lung was successfully re-expanded using positive end-expiratory pressure (PEEP) ventilation under real-time ultrasound monitoring, and closed thoracic drainage was avoided. Therefore, the correct use of ultrasound can identify the adequate PEEP level that is able to promote resolution of pneumothorax induced by diaphragmatic injury. SAGE Publications 2020-01-22 /pmc/articles/PMC7113711/ /pubmed/31964200 http://dx.doi.org/10.1177/0300060519898048 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc/4.0/ Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Case Report
Han, Qiang
Wang, Beibei
Xu, Aijun
Use of intraoperative ultrasonography for identification and management of pneumothorax caused by iatrogenic diaphragm defect: a case report and literature review
title Use of intraoperative ultrasonography for identification and management of pneumothorax caused by iatrogenic diaphragm defect: a case report and literature review
title_full Use of intraoperative ultrasonography for identification and management of pneumothorax caused by iatrogenic diaphragm defect: a case report and literature review
title_fullStr Use of intraoperative ultrasonography for identification and management of pneumothorax caused by iatrogenic diaphragm defect: a case report and literature review
title_full_unstemmed Use of intraoperative ultrasonography for identification and management of pneumothorax caused by iatrogenic diaphragm defect: a case report and literature review
title_short Use of intraoperative ultrasonography for identification and management of pneumothorax caused by iatrogenic diaphragm defect: a case report and literature review
title_sort use of intraoperative ultrasonography for identification and management of pneumothorax caused by iatrogenic diaphragm defect: a case report and literature review
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7113711/
https://www.ncbi.nlm.nih.gov/pubmed/31964200
http://dx.doi.org/10.1177/0300060519898048
work_keys_str_mv AT hanqiang useofintraoperativeultrasonographyforidentificationandmanagementofpneumothoraxcausedbyiatrogenicdiaphragmdefectacasereportandliteraturereview
AT wangbeibei useofintraoperativeultrasonographyforidentificationandmanagementofpneumothoraxcausedbyiatrogenicdiaphragmdefectacasereportandliteraturereview
AT xuaijun useofintraoperativeultrasonographyforidentificationandmanagementofpneumothoraxcausedbyiatrogenicdiaphragmdefectacasereportandliteraturereview