Cargando…

Experimental analysis of the humidification of air in bubble columns for thermal water treatment systems(☆)

The humidification-dehumidification process (HDH) for desalination is a promising technology to address water scarcity issues in rural regions. However, a low humidifier efficiency is a weakness of the process. Bubble column humidifiers (BCH) are promising for HDH, as they provide enhanced heat and...

Descripción completa

Detalles Bibliográficos
Autores principales: Eder, Elias, Preißinger, Markus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7116115/
https://www.ncbi.nlm.nih.gov/pubmed/32983285
http://dx.doi.org/10.1016/j.expthermflusci.2020.110063
_version_ 1783514195802718208
author Eder, Elias
Preißinger, Markus
author_facet Eder, Elias
Preißinger, Markus
author_sort Eder, Elias
collection PubMed
description The humidification-dehumidification process (HDH) for desalination is a promising technology to address water scarcity issues in rural regions. However, a low humidifier efficiency is a weakness of the process. Bubble column humidifiers (BCH) are promising for HDH, as they provide enhanced heat and mass transfer and have low maintenance requirements. Previous studies of HDH-systems with BCHs draw different conclusions regarding the impact of superficial air velocity and liquid height on the humidification. Furthermore, the impact of flow characteristics has never been investigated systematically at all. In this study, an optimized BCH test setup that allows for optical analysis of the humidifier is used and evaluated. Our test setup is validated, since the influence of water temperature on the humidification, which is exponential, is reproduced. Measurements with seawater show that the normalised system productivity is increased by about 56% with an increase in superficial air velocity from 0.5 cm/s to 5 cm/s. Furthermore, the system productivity is increased by around 29% with an increase in liquid height from 60 mm to 378 mm. While the impact of superficial air velocity can be traced back to temperature changes at the humidifier and dehumidifier outlets, the impact of liquid height is shown to be caused by a smaller heat loss surface in the humidifier with an increase in liquid height. For the impact of sieve plate orifice diameter, a clear influence on the humidification is not apparent, this parameter needs to be investigated further. Finally, our new test setup allows for analysing the humidification of air (1) in a systematic way, (2) in relevant measurement ranges and (3) in comparison with optical analyses of the flow characteristics.
format Online
Article
Text
id pubmed-7116115
institution National Center for Biotechnology Information
language English
publishDate 2020
record_format MEDLINE/PubMed
spelling pubmed-71161152020-09-24 Experimental analysis of the humidification of air in bubble columns for thermal water treatment systems(☆) Eder, Elias Preißinger, Markus Exp Therm Fluid Sci Article The humidification-dehumidification process (HDH) for desalination is a promising technology to address water scarcity issues in rural regions. However, a low humidifier efficiency is a weakness of the process. Bubble column humidifiers (BCH) are promising for HDH, as they provide enhanced heat and mass transfer and have low maintenance requirements. Previous studies of HDH-systems with BCHs draw different conclusions regarding the impact of superficial air velocity and liquid height on the humidification. Furthermore, the impact of flow characteristics has never been investigated systematically at all. In this study, an optimized BCH test setup that allows for optical analysis of the humidifier is used and evaluated. Our test setup is validated, since the influence of water temperature on the humidification, which is exponential, is reproduced. Measurements with seawater show that the normalised system productivity is increased by about 56% with an increase in superficial air velocity from 0.5 cm/s to 5 cm/s. Furthermore, the system productivity is increased by around 29% with an increase in liquid height from 60 mm to 378 mm. While the impact of superficial air velocity can be traced back to temperature changes at the humidifier and dehumidifier outlets, the impact of liquid height is shown to be caused by a smaller heat loss surface in the humidifier with an increase in liquid height. For the impact of sieve plate orifice diameter, a clear influence on the humidification is not apparent, this parameter needs to be investigated further. Finally, our new test setup allows for analysing the humidification of air (1) in a systematic way, (2) in relevant measurement ranges and (3) in comparison with optical analyses of the flow characteristics. 2020-02-13 /pmc/articles/PMC7116115/ /pubmed/32983285 http://dx.doi.org/10.1016/j.expthermflusci.2020.110063 Text en http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Eder, Elias
Preißinger, Markus
Experimental analysis of the humidification of air in bubble columns for thermal water treatment systems(☆)
title Experimental analysis of the humidification of air in bubble columns for thermal water treatment systems(☆)
title_full Experimental analysis of the humidification of air in bubble columns for thermal water treatment systems(☆)
title_fullStr Experimental analysis of the humidification of air in bubble columns for thermal water treatment systems(☆)
title_full_unstemmed Experimental analysis of the humidification of air in bubble columns for thermal water treatment systems(☆)
title_short Experimental analysis of the humidification of air in bubble columns for thermal water treatment systems(☆)
title_sort experimental analysis of the humidification of air in bubble columns for thermal water treatment systems(☆)
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7116115/
https://www.ncbi.nlm.nih.gov/pubmed/32983285
http://dx.doi.org/10.1016/j.expthermflusci.2020.110063
work_keys_str_mv AT ederelias experimentalanalysisofthehumidificationofairinbubblecolumnsforthermalwatertreatmentsystems
AT preißingermarkus experimentalanalysisofthehumidificationofairinbubblecolumnsforthermalwatertreatmentsystems