A field study on indoor environment quality of Chinese inpatient buildings in a hot and humid region
In this research, objective physical measurements and subjective questionnaire surveys are used to investigate the indoor environment quality of Chinese inpatient buildings. The relative humidity in the inpatient buildings reaches 65%–75% during summer, resulting in the regular appearance of microbi...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier Ltd.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7116981/ https://www.ncbi.nlm.nih.gov/pubmed/32287989 http://dx.doi.org/10.1016/j.buildenv.2019.01.046 |
_version_ | 1783514274934554624 |
---|---|
author | Tang, Haida Ding, Jianhua Li, Chunying Li, Jiaxiong |
author_facet | Tang, Haida Ding, Jianhua Li, Chunying Li, Jiaxiong |
author_sort | Tang, Haida |
collection | PubMed |
description | In this research, objective physical measurements and subjective questionnaire surveys are used to investigate the indoor environment quality of Chinese inpatient buildings. The relative humidity in the inpatient buildings reaches 65%–75% during summer, resulting in the regular appearance of microbial growth on indoor surfaces. The average outdoor air change rate measured through the CO(2) concentration decay method in the sampled inpatient rooms is 1.1 h(−1), which is 45% below the standard threshold. The CO(2) concentration in over 99% of the functional spaces is below the threshold of 1000 ppm. However, the dissatisfaction rate of the air freshness is higher than 25%, owing to the characteristics of healthcare activities. Insufficient fresh air volume and high supply air humidity ratio of the outdoor air system result in the inadequate dehumidification capacity and the over-humid environment in the inpatient buildings. From the perspective of indoor TVOC and PM2.5 concentration, a hospitable IAQ is achieved in the inpatient buildings. In the nurse unit, the illumination levels in public areas, such as patient corridors and nurse stations, are inadequate. The average noise levels (A) in the inpatient rooms and nurse stations are 50.7 and 61.6 dB, respectively, which exceeds the Chinese standard. According to the subjective survey, the dissatisfaction rates of overall IEQ in the summer for patients and visitors are 7.9% and 10.4%, respectively, while for staff it is 34.8%. Statistical analysis reveals that the satisfaction levels of the patient with the IEQ are higher than that of the visitor and staff. |
format | Online Article Text |
id | pubmed-7116981 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier Ltd. |
record_format | MEDLINE/PubMed |
spelling | pubmed-71169812020-04-02 A field study on indoor environment quality of Chinese inpatient buildings in a hot and humid region Tang, Haida Ding, Jianhua Li, Chunying Li, Jiaxiong Build Environ Article In this research, objective physical measurements and subjective questionnaire surveys are used to investigate the indoor environment quality of Chinese inpatient buildings. The relative humidity in the inpatient buildings reaches 65%–75% during summer, resulting in the regular appearance of microbial growth on indoor surfaces. The average outdoor air change rate measured through the CO(2) concentration decay method in the sampled inpatient rooms is 1.1 h(−1), which is 45% below the standard threshold. The CO(2) concentration in over 99% of the functional spaces is below the threshold of 1000 ppm. However, the dissatisfaction rate of the air freshness is higher than 25%, owing to the characteristics of healthcare activities. Insufficient fresh air volume and high supply air humidity ratio of the outdoor air system result in the inadequate dehumidification capacity and the over-humid environment in the inpatient buildings. From the perspective of indoor TVOC and PM2.5 concentration, a hospitable IAQ is achieved in the inpatient buildings. In the nurse unit, the illumination levels in public areas, such as patient corridors and nurse stations, are inadequate. The average noise levels (A) in the inpatient rooms and nurse stations are 50.7 and 61.6 dB, respectively, which exceeds the Chinese standard. According to the subjective survey, the dissatisfaction rates of overall IEQ in the summer for patients and visitors are 7.9% and 10.4%, respectively, while for staff it is 34.8%. Statistical analysis reveals that the satisfaction levels of the patient with the IEQ are higher than that of the visitor and staff. Elsevier Ltd. 2019-03-15 2019-01-29 /pmc/articles/PMC7116981/ /pubmed/32287989 http://dx.doi.org/10.1016/j.buildenv.2019.01.046 Text en © 2019 Elsevier Ltd. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Tang, Haida Ding, Jianhua Li, Chunying Li, Jiaxiong A field study on indoor environment quality of Chinese inpatient buildings in a hot and humid region |
title | A field study on indoor environment quality of Chinese inpatient buildings in a hot and humid region |
title_full | A field study on indoor environment quality of Chinese inpatient buildings in a hot and humid region |
title_fullStr | A field study on indoor environment quality of Chinese inpatient buildings in a hot and humid region |
title_full_unstemmed | A field study on indoor environment quality of Chinese inpatient buildings in a hot and humid region |
title_short | A field study on indoor environment quality of Chinese inpatient buildings in a hot and humid region |
title_sort | field study on indoor environment quality of chinese inpatient buildings in a hot and humid region |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7116981/ https://www.ncbi.nlm.nih.gov/pubmed/32287989 http://dx.doi.org/10.1016/j.buildenv.2019.01.046 |
work_keys_str_mv | AT tanghaida afieldstudyonindoorenvironmentqualityofchineseinpatientbuildingsinahotandhumidregion AT dingjianhua afieldstudyonindoorenvironmentqualityofchineseinpatientbuildingsinahotandhumidregion AT lichunying afieldstudyonindoorenvironmentqualityofchineseinpatientbuildingsinahotandhumidregion AT lijiaxiong afieldstudyonindoorenvironmentqualityofchineseinpatientbuildingsinahotandhumidregion AT tanghaida fieldstudyonindoorenvironmentqualityofchineseinpatientbuildingsinahotandhumidregion AT dingjianhua fieldstudyonindoorenvironmentqualityofchineseinpatientbuildingsinahotandhumidregion AT lichunying fieldstudyonindoorenvironmentqualityofchineseinpatientbuildingsinahotandhumidregion AT lijiaxiong fieldstudyonindoorenvironmentqualityofchineseinpatientbuildingsinahotandhumidregion |