Cargando…

Modelling of evaporation of cough droplets in inhomogeneous humidity fields using the multi-component Eulerian-Lagrangian approach

This study employed a multi-component Eulerian-Lagrangian approach to model the evaporation and dispersion of cough droplets in quiescent air. The approach is featured with a continuity equation being explicitly solved for water vapor, which allows comprehensively considering the effects of inhomoge...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Xiangdong, Shang, Yidan, Yan, Yihuan, Yang, Lin, Tu, Jiyuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier Ltd. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7117029/
https://www.ncbi.nlm.nih.gov/pubmed/32287977
http://dx.doi.org/10.1016/j.buildenv.2017.11.025
_version_ 1783514285659389952
author Li, Xiangdong
Shang, Yidan
Yan, Yihuan
Yang, Lin
Tu, Jiyuan
author_facet Li, Xiangdong
Shang, Yidan
Yan, Yihuan
Yang, Lin
Tu, Jiyuan
author_sort Li, Xiangdong
collection PubMed
description This study employed a multi-component Eulerian-Lagrangian approach to model the evaporation and dispersion of cough droplets in quiescent air. The approach is featured with a continuity equation being explicitly solved for water vapor, which allows comprehensively considering the effects of inhomogeneous humidity field on droplets evaporation and movement. The computational fluid dynamics (CFD) computations based on the approach achieved a satisfactory agreement with the theoretical models reported in the literature. The results demonstrated that the evaporation-generated vapor and super-saturated wet air exhaled from the respiratory tracks forms a “vapor plume” in front of the respiratory track opening, which, despite the short life time, significantly impedes the evaporation of the droplets captured in it. The study also revealed that due to the droplet size reduction induced by evaporation, both the number density of airborne droplets and mass concentration of inhalable pathogens remarkably increased, which can result in a higher risk of infection. Parametric studies were finally conducted to evaluate the factors affecting droplet evaporation. SUMMARY: The study demonstrated the importance of considering inhomogeneous humidity field when modelling the evaporation and dispersion of cough droplets. The multi-component Eulerian-Lagrangian model presented in this study provides a comprehensive approach to address different influential factors in a wide parametric range, which will enhance the assessment of the health risks associated with droplet exposure.
format Online
Article
Text
id pubmed-7117029
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier Ltd.
record_format MEDLINE/PubMed
spelling pubmed-71170292020-04-02 Modelling of evaporation of cough droplets in inhomogeneous humidity fields using the multi-component Eulerian-Lagrangian approach Li, Xiangdong Shang, Yidan Yan, Yihuan Yang, Lin Tu, Jiyuan Build Environ Article This study employed a multi-component Eulerian-Lagrangian approach to model the evaporation and dispersion of cough droplets in quiescent air. The approach is featured with a continuity equation being explicitly solved for water vapor, which allows comprehensively considering the effects of inhomogeneous humidity field on droplets evaporation and movement. The computational fluid dynamics (CFD) computations based on the approach achieved a satisfactory agreement with the theoretical models reported in the literature. The results demonstrated that the evaporation-generated vapor and super-saturated wet air exhaled from the respiratory tracks forms a “vapor plume” in front of the respiratory track opening, which, despite the short life time, significantly impedes the evaporation of the droplets captured in it. The study also revealed that due to the droplet size reduction induced by evaporation, both the number density of airborne droplets and mass concentration of inhalable pathogens remarkably increased, which can result in a higher risk of infection. Parametric studies were finally conducted to evaluate the factors affecting droplet evaporation. SUMMARY: The study demonstrated the importance of considering inhomogeneous humidity field when modelling the evaporation and dispersion of cough droplets. The multi-component Eulerian-Lagrangian model presented in this study provides a comprehensive approach to address different influential factors in a wide parametric range, which will enhance the assessment of the health risks associated with droplet exposure. Elsevier Ltd. 2018-01-15 2017-11-21 /pmc/articles/PMC7117029/ /pubmed/32287977 http://dx.doi.org/10.1016/j.buildenv.2017.11.025 Text en © 2017 Elsevier Ltd. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Li, Xiangdong
Shang, Yidan
Yan, Yihuan
Yang, Lin
Tu, Jiyuan
Modelling of evaporation of cough droplets in inhomogeneous humidity fields using the multi-component Eulerian-Lagrangian approach
title Modelling of evaporation of cough droplets in inhomogeneous humidity fields using the multi-component Eulerian-Lagrangian approach
title_full Modelling of evaporation of cough droplets in inhomogeneous humidity fields using the multi-component Eulerian-Lagrangian approach
title_fullStr Modelling of evaporation of cough droplets in inhomogeneous humidity fields using the multi-component Eulerian-Lagrangian approach
title_full_unstemmed Modelling of evaporation of cough droplets in inhomogeneous humidity fields using the multi-component Eulerian-Lagrangian approach
title_short Modelling of evaporation of cough droplets in inhomogeneous humidity fields using the multi-component Eulerian-Lagrangian approach
title_sort modelling of evaporation of cough droplets in inhomogeneous humidity fields using the multi-component eulerian-lagrangian approach
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7117029/
https://www.ncbi.nlm.nih.gov/pubmed/32287977
http://dx.doi.org/10.1016/j.buildenv.2017.11.025
work_keys_str_mv AT lixiangdong modellingofevaporationofcoughdropletsininhomogeneoushumidityfieldsusingthemulticomponenteulerianlagrangianapproach
AT shangyidan modellingofevaporationofcoughdropletsininhomogeneoushumidityfieldsusingthemulticomponenteulerianlagrangianapproach
AT yanyihuan modellingofevaporationofcoughdropletsininhomogeneoushumidityfieldsusingthemulticomponenteulerianlagrangianapproach
AT yanglin modellingofevaporationofcoughdropletsininhomogeneoushumidityfieldsusingthemulticomponenteulerianlagrangianapproach
AT tujiyuan modellingofevaporationofcoughdropletsininhomogeneoushumidityfieldsusingthemulticomponenteulerianlagrangianapproach