Cargando…
A new visually improved and sensitive loop mediated isothermal amplification (LAMP) for diagnosis of symptomatic falciparum malaria
Molecular diagnosis of malaria by nucleotide amplification requires sophisticated and expensive instruments, typically found only in well-established laboratories. Loop-mediated isothermal amplification (LAMP) has provided a new platform for an easily adaptable molecular technique for molecular diag...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier B.V.
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7117200/ https://www.ncbi.nlm.nih.gov/pubmed/24613155 http://dx.doi.org/10.1016/j.actatropica.2014.02.016 |
_version_ | 1783514317499400192 |
---|---|
author | Mohon, Abu Naser Elahi, Rubayet Khan, Wasif A. Haque, Rashidul Sullivan, David J. Alam, Mohammad Shafiul |
author_facet | Mohon, Abu Naser Elahi, Rubayet Khan, Wasif A. Haque, Rashidul Sullivan, David J. Alam, Mohammad Shafiul |
author_sort | Mohon, Abu Naser |
collection | PubMed |
description | Molecular diagnosis of malaria by nucleotide amplification requires sophisticated and expensive instruments, typically found only in well-established laboratories. Loop-mediated isothermal amplification (LAMP) has provided a new platform for an easily adaptable molecular technique for molecular diagnosis of malaria without the use of expensive instruments. A new primer set has been designed targeting the 18S rRNA gene for the detection of Plasmodium falciparum in whole blood samples. The efficacy of LAMP using the new primer set was assessed in this study in comparison to that of a previously described set of LAMP primers as well as with microscopy and real-time PCR as reference methods for detecting P. falciparum. Pre-addition of hydroxy napthol blue (HNB) in the LAMP reaction caused a distinct color change, thereby improving the visual detection system. The new LAMP assay was found to be 99.1% sensitive compared to microscopy and 98.1% when compared to real-time PCR. Meanwhile, its specificity was 99% and 100% in contrast to microscopy and real-time PCR, respectively. Moreover, the LAMP method was in very good agreement with microscopy and real-time PCR (0.94 and 0.98, respectively). This new LAMP method can detect at least 5 parasites/μL of infected blood within 35 min, while the other LAMP method tested in this study, could detect a minimum of 100 parasites/μL of human blood after 60 min of amplification. Thus, the new method is sensitive and specific, can be carried out in a very short time, and can substitute PCR in healthcare clinics and standard laboratories. |
format | Online Article Text |
id | pubmed-7117200 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Elsevier B.V. |
record_format | MEDLINE/PubMed |
spelling | pubmed-71172002020-04-02 A new visually improved and sensitive loop mediated isothermal amplification (LAMP) for diagnosis of symptomatic falciparum malaria Mohon, Abu Naser Elahi, Rubayet Khan, Wasif A. Haque, Rashidul Sullivan, David J. Alam, Mohammad Shafiul Acta Trop Article Molecular diagnosis of malaria by nucleotide amplification requires sophisticated and expensive instruments, typically found only in well-established laboratories. Loop-mediated isothermal amplification (LAMP) has provided a new platform for an easily adaptable molecular technique for molecular diagnosis of malaria without the use of expensive instruments. A new primer set has been designed targeting the 18S rRNA gene for the detection of Plasmodium falciparum in whole blood samples. The efficacy of LAMP using the new primer set was assessed in this study in comparison to that of a previously described set of LAMP primers as well as with microscopy and real-time PCR as reference methods for detecting P. falciparum. Pre-addition of hydroxy napthol blue (HNB) in the LAMP reaction caused a distinct color change, thereby improving the visual detection system. The new LAMP assay was found to be 99.1% sensitive compared to microscopy and 98.1% when compared to real-time PCR. Meanwhile, its specificity was 99% and 100% in contrast to microscopy and real-time PCR, respectively. Moreover, the LAMP method was in very good agreement with microscopy and real-time PCR (0.94 and 0.98, respectively). This new LAMP method can detect at least 5 parasites/μL of infected blood within 35 min, while the other LAMP method tested in this study, could detect a minimum of 100 parasites/μL of human blood after 60 min of amplification. Thus, the new method is sensitive and specific, can be carried out in a very short time, and can substitute PCR in healthcare clinics and standard laboratories. Elsevier B.V. 2014-06 2014-03-05 /pmc/articles/PMC7117200/ /pubmed/24613155 http://dx.doi.org/10.1016/j.actatropica.2014.02.016 Text en Copyright © 2014 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Mohon, Abu Naser Elahi, Rubayet Khan, Wasif A. Haque, Rashidul Sullivan, David J. Alam, Mohammad Shafiul A new visually improved and sensitive loop mediated isothermal amplification (LAMP) for diagnosis of symptomatic falciparum malaria |
title | A new visually improved and sensitive loop mediated isothermal amplification (LAMP) for diagnosis of symptomatic falciparum malaria |
title_full | A new visually improved and sensitive loop mediated isothermal amplification (LAMP) for diagnosis of symptomatic falciparum malaria |
title_fullStr | A new visually improved and sensitive loop mediated isothermal amplification (LAMP) for diagnosis of symptomatic falciparum malaria |
title_full_unstemmed | A new visually improved and sensitive loop mediated isothermal amplification (LAMP) for diagnosis of symptomatic falciparum malaria |
title_short | A new visually improved and sensitive loop mediated isothermal amplification (LAMP) for diagnosis of symptomatic falciparum malaria |
title_sort | new visually improved and sensitive loop mediated isothermal amplification (lamp) for diagnosis of symptomatic falciparum malaria |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7117200/ https://www.ncbi.nlm.nih.gov/pubmed/24613155 http://dx.doi.org/10.1016/j.actatropica.2014.02.016 |
work_keys_str_mv | AT mohonabunaser anewvisuallyimprovedandsensitiveloopmediatedisothermalamplificationlampfordiagnosisofsymptomaticfalciparummalaria AT elahirubayet anewvisuallyimprovedandsensitiveloopmediatedisothermalamplificationlampfordiagnosisofsymptomaticfalciparummalaria AT khanwasifa anewvisuallyimprovedandsensitiveloopmediatedisothermalamplificationlampfordiagnosisofsymptomaticfalciparummalaria AT haquerashidul anewvisuallyimprovedandsensitiveloopmediatedisothermalamplificationlampfordiagnosisofsymptomaticfalciparummalaria AT sullivandavidj anewvisuallyimprovedandsensitiveloopmediatedisothermalamplificationlampfordiagnosisofsymptomaticfalciparummalaria AT alammohammadshafiul anewvisuallyimprovedandsensitiveloopmediatedisothermalamplificationlampfordiagnosisofsymptomaticfalciparummalaria AT mohonabunaser newvisuallyimprovedandsensitiveloopmediatedisothermalamplificationlampfordiagnosisofsymptomaticfalciparummalaria AT elahirubayet newvisuallyimprovedandsensitiveloopmediatedisothermalamplificationlampfordiagnosisofsymptomaticfalciparummalaria AT khanwasifa newvisuallyimprovedandsensitiveloopmediatedisothermalamplificationlampfordiagnosisofsymptomaticfalciparummalaria AT haquerashidul newvisuallyimprovedandsensitiveloopmediatedisothermalamplificationlampfordiagnosisofsymptomaticfalciparummalaria AT sullivandavidj newvisuallyimprovedandsensitiveloopmediatedisothermalamplificationlampfordiagnosisofsymptomaticfalciparummalaria AT alammohammadshafiul newvisuallyimprovedandsensitiveloopmediatedisothermalamplificationlampfordiagnosisofsymptomaticfalciparummalaria |