Cargando…
Hb Phnom Penh Showing Falsely High or Reasonable HbA1c Values Depending on the Type of High-performance Liquid Chromatography System
We herein report a 50-year-old Chinese woman with Hb Phnom Penh (α117Phe-Ile-α118Thr) showing high or reasonable HbA1c values depending on the type of high-performance liquid chromatography (HPLC) system. A high HbA1c value of 7.5% (HPLC assay: G9) and a reasonable HbA1c value of 5.2% (assay unknown...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japanese Society of Internal Medicine
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7118387/ https://www.ncbi.nlm.nih.gov/pubmed/31787693 http://dx.doi.org/10.2169/internalmedicine.3306-19 |
_version_ | 1783514553465700352 |
---|---|
author | Hara, Kenji Koga, Masafumi Shinozaki, Hiroyuki Yamauchi, Mototaka Suzuki, Tatsuhiko Naruse, Rika Tsuchiya, Takafumi Takebayashi, Kohzo Inukai, Toshihiko Hashimoto, Koshi |
author_facet | Hara, Kenji Koga, Masafumi Shinozaki, Hiroyuki Yamauchi, Mototaka Suzuki, Tatsuhiko Naruse, Rika Tsuchiya, Takafumi Takebayashi, Kohzo Inukai, Toshihiko Hashimoto, Koshi |
author_sort | Hara, Kenji |
collection | PubMed |
description | We herein report a 50-year-old Chinese woman with Hb Phnom Penh (α117Phe-Ile-α118Thr) showing high or reasonable HbA1c values depending on the type of high-performance liquid chromatography (HPLC) system. A high HbA1c value of 7.5% (HPLC assay: G9) and a reasonable HbA1c value of 5.2% (assay unknown) were observed. Therefore, the patient was refereed to our hospital; the oral glucose tolerance test showed normal glucose tolerance. The HbA1c values measured by an enzymatic assay, immunoassay, and affinity assay, as well as most HPLC assays were within the reference range, whereas those measured by the Tosoh HPLC systems were high. |
format | Online Article Text |
id | pubmed-7118387 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | The Japanese Society of Internal Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-71183872020-04-07 Hb Phnom Penh Showing Falsely High or Reasonable HbA1c Values Depending on the Type of High-performance Liquid Chromatography System Hara, Kenji Koga, Masafumi Shinozaki, Hiroyuki Yamauchi, Mototaka Suzuki, Tatsuhiko Naruse, Rika Tsuchiya, Takafumi Takebayashi, Kohzo Inukai, Toshihiko Hashimoto, Koshi Intern Med Case Report We herein report a 50-year-old Chinese woman with Hb Phnom Penh (α117Phe-Ile-α118Thr) showing high or reasonable HbA1c values depending on the type of high-performance liquid chromatography (HPLC) system. A high HbA1c value of 7.5% (HPLC assay: G9) and a reasonable HbA1c value of 5.2% (assay unknown) were observed. Therefore, the patient was refereed to our hospital; the oral glucose tolerance test showed normal glucose tolerance. The HbA1c values measured by an enzymatic assay, immunoassay, and affinity assay, as well as most HPLC assays were within the reference range, whereas those measured by the Tosoh HPLC systems were high. The Japanese Society of Internal Medicine 2019-11-29 2020-03-15 /pmc/articles/PMC7118387/ /pubmed/31787693 http://dx.doi.org/10.2169/internalmedicine.3306-19 Text en Copyright © 2020 by The Japanese Society of Internal Medicine https://creativecommons.org/licenses/by-nc-nd/4.0/ The Internal Medicine is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Hara, Kenji Koga, Masafumi Shinozaki, Hiroyuki Yamauchi, Mototaka Suzuki, Tatsuhiko Naruse, Rika Tsuchiya, Takafumi Takebayashi, Kohzo Inukai, Toshihiko Hashimoto, Koshi Hb Phnom Penh Showing Falsely High or Reasonable HbA1c Values Depending on the Type of High-performance Liquid Chromatography System |
title | Hb Phnom Penh Showing Falsely High or Reasonable HbA1c Values Depending on the Type of High-performance Liquid Chromatography System |
title_full | Hb Phnom Penh Showing Falsely High or Reasonable HbA1c Values Depending on the Type of High-performance Liquid Chromatography System |
title_fullStr | Hb Phnom Penh Showing Falsely High or Reasonable HbA1c Values Depending on the Type of High-performance Liquid Chromatography System |
title_full_unstemmed | Hb Phnom Penh Showing Falsely High or Reasonable HbA1c Values Depending on the Type of High-performance Liquid Chromatography System |
title_short | Hb Phnom Penh Showing Falsely High or Reasonable HbA1c Values Depending on the Type of High-performance Liquid Chromatography System |
title_sort | hb phnom penh showing falsely high or reasonable hba1c values depending on the type of high-performance liquid chromatography system |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7118387/ https://www.ncbi.nlm.nih.gov/pubmed/31787693 http://dx.doi.org/10.2169/internalmedicine.3306-19 |
work_keys_str_mv | AT harakenji hbphnompenhshowingfalselyhighorreasonablehba1cvaluesdependingonthetypeofhighperformanceliquidchromatographysystem AT kogamasafumi hbphnompenhshowingfalselyhighorreasonablehba1cvaluesdependingonthetypeofhighperformanceliquidchromatographysystem AT shinozakihiroyuki hbphnompenhshowingfalselyhighorreasonablehba1cvaluesdependingonthetypeofhighperformanceliquidchromatographysystem AT yamauchimototaka hbphnompenhshowingfalselyhighorreasonablehba1cvaluesdependingonthetypeofhighperformanceliquidchromatographysystem AT suzukitatsuhiko hbphnompenhshowingfalselyhighorreasonablehba1cvaluesdependingonthetypeofhighperformanceliquidchromatographysystem AT naruserika hbphnompenhshowingfalselyhighorreasonablehba1cvaluesdependingonthetypeofhighperformanceliquidchromatographysystem AT tsuchiyatakafumi hbphnompenhshowingfalselyhighorreasonablehba1cvaluesdependingonthetypeofhighperformanceliquidchromatographysystem AT takebayashikohzo hbphnompenhshowingfalselyhighorreasonablehba1cvaluesdependingonthetypeofhighperformanceliquidchromatographysystem AT inukaitoshihiko hbphnompenhshowingfalselyhighorreasonablehba1cvaluesdependingonthetypeofhighperformanceliquidchromatographysystem AT hashimotokoshi hbphnompenhshowingfalselyhighorreasonablehba1cvaluesdependingonthetypeofhighperformanceliquidchromatographysystem |