Cargando…
Surgical Outcomes of a Second Ahmed Glaucoma Valve Implantation in Asian Eyes with Refractory Glaucoma
RESULTS: The cumulative failure rates were 9.5%, 20.0%, 32.5%, and 46.0% at six months, one year, two years, and three years of follow-up. At final follow-up, complete success and qualified success rates were 23.8% and 33.3%, respectively; mean IOP and number of medications decreased by 5.6 mmHg (23...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7125488/ https://www.ncbi.nlm.nih.gov/pubmed/32280538 http://dx.doi.org/10.1155/2020/8741301 |
Sumario: | RESULTS: The cumulative failure rates were 9.5%, 20.0%, 32.5%, and 46.0% at six months, one year, two years, and three years of follow-up. At final follow-up, complete success and qualified success rates were 23.8% and 33.3%, respectively; mean IOP and number of medications decreased by 5.6 mmHg (23.9%) and 1.7 mmHg (54.8%), respectively, from preoperative baseline (P < 0.01). More common postoperative complications included hypertensive phase (38.1%), corneal decompensation (23.8%), and tube exposure (14.3%). CONCLUSION: An additional AGV implant had good short and modest long-term effectiveness in reducing IOP following a failed glaucoma tube shunt in Asian eyes, with the mentioned common postoperative complications to be actively monitored and managed. |
---|