Cargando…

A simple and compact smartphone-based device for the quantitative readout of colloidal gold lateral flow immunoassay strips

Colloidal gold lateral flow immunoassay strips (AuNPs-LFIS) have been widely applied as qualitative diagnostic tools for point-of-care tests (POCT). If strip readers were incorporated, their use could be extended to quantitative analysis. However, their cost and non-portability render commercial str...

Descripción completa

Detalles Bibliográficos
Autores principales: Xiao, Wei, Huang, Caihong, Xu, Fei, Yan, Junjie, Bian, Hongfen, Fu, Qiangqiang, Xie, Kaixin, Wang, Lei, Tang, Yong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier B.V. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7127147/
https://www.ncbi.nlm.nih.gov/pubmed/32288251
http://dx.doi.org/10.1016/j.snb.2018.03.110
_version_ 1783516297909239808
author Xiao, Wei
Huang, Caihong
Xu, Fei
Yan, Junjie
Bian, Hongfen
Fu, Qiangqiang
Xie, Kaixin
Wang, Lei
Tang, Yong
author_facet Xiao, Wei
Huang, Caihong
Xu, Fei
Yan, Junjie
Bian, Hongfen
Fu, Qiangqiang
Xie, Kaixin
Wang, Lei
Tang, Yong
author_sort Xiao, Wei
collection PubMed
description Colloidal gold lateral flow immunoassay strips (AuNPs-LFIS) have been widely applied as qualitative diagnostic tools for point-of-care tests (POCT). If strip readers were incorporated, their use could be extended to quantitative analysis. However, their cost and non-portability render commercial strip readers unavailable for use in either home testing, community or rural hospital diagnosis. This is particularly true for on-site testing. Here, a smartphone-based reader was designed and 3D-printed for quantitatively assess AuNPs-LFIS. The basic principle of the devise was relying on a smartphone’s ambient light sensor (SPALS). This sensor was harnessed to measure the transmitted light intensities originating from the T-lines on the strips, the transmitted light intensities vary with concentration of AuNP on the T-lines. To validate this approach, our newly developed smartphone’s ambient light sensor-based reader (SPALS-reader) was used to readout AuNPs-LFIS of three analytical targets: cadmium ion (Cd(2+); limit of detection (LOD) was 0.16 ng/mL), clenbuterol (CL; LOD was 0.046 ng/mL), and porcine epidemic diarrhea virus (PEDV; LOD was 0.055 μg/mL). The result showed good consistency with the results of conventional image analysis approaches, indicating that the smartphone-based device is appropriate for use in AuNPs-LFIS readouts. Compared with the traditional analysis method, the developed AuNPs-LFIS reader is easier operated, lower cost and more portable, which provided an on-site quantitative analysis tool for AuNPs-LFIS and enhances the applied range of AuNPs-LFIS.
format Online
Article
Text
id pubmed-7127147
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier B.V.
record_format MEDLINE/PubMed
spelling pubmed-71271472020-04-08 A simple and compact smartphone-based device for the quantitative readout of colloidal gold lateral flow immunoassay strips Xiao, Wei Huang, Caihong Xu, Fei Yan, Junjie Bian, Hongfen Fu, Qiangqiang Xie, Kaixin Wang, Lei Tang, Yong Sens Actuators B Chem Article Colloidal gold lateral flow immunoassay strips (AuNPs-LFIS) have been widely applied as qualitative diagnostic tools for point-of-care tests (POCT). If strip readers were incorporated, their use could be extended to quantitative analysis. However, their cost and non-portability render commercial strip readers unavailable for use in either home testing, community or rural hospital diagnosis. This is particularly true for on-site testing. Here, a smartphone-based reader was designed and 3D-printed for quantitatively assess AuNPs-LFIS. The basic principle of the devise was relying on a smartphone’s ambient light sensor (SPALS). This sensor was harnessed to measure the transmitted light intensities originating from the T-lines on the strips, the transmitted light intensities vary with concentration of AuNP on the T-lines. To validate this approach, our newly developed smartphone’s ambient light sensor-based reader (SPALS-reader) was used to readout AuNPs-LFIS of three analytical targets: cadmium ion (Cd(2+); limit of detection (LOD) was 0.16 ng/mL), clenbuterol (CL; LOD was 0.046 ng/mL), and porcine epidemic diarrhea virus (PEDV; LOD was 0.055 μg/mL). The result showed good consistency with the results of conventional image analysis approaches, indicating that the smartphone-based device is appropriate for use in AuNPs-LFIS readouts. Compared with the traditional analysis method, the developed AuNPs-LFIS reader is easier operated, lower cost and more portable, which provided an on-site quantitative analysis tool for AuNPs-LFIS and enhances the applied range of AuNPs-LFIS. Elsevier B.V. 2018-08-01 2018-03-20 /pmc/articles/PMC7127147/ /pubmed/32288251 http://dx.doi.org/10.1016/j.snb.2018.03.110 Text en © 2018 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Xiao, Wei
Huang, Caihong
Xu, Fei
Yan, Junjie
Bian, Hongfen
Fu, Qiangqiang
Xie, Kaixin
Wang, Lei
Tang, Yong
A simple and compact smartphone-based device for the quantitative readout of colloidal gold lateral flow immunoassay strips
title A simple and compact smartphone-based device for the quantitative readout of colloidal gold lateral flow immunoassay strips
title_full A simple and compact smartphone-based device for the quantitative readout of colloidal gold lateral flow immunoassay strips
title_fullStr A simple and compact smartphone-based device for the quantitative readout of colloidal gold lateral flow immunoassay strips
title_full_unstemmed A simple and compact smartphone-based device for the quantitative readout of colloidal gold lateral flow immunoassay strips
title_short A simple and compact smartphone-based device for the quantitative readout of colloidal gold lateral flow immunoassay strips
title_sort simple and compact smartphone-based device for the quantitative readout of colloidal gold lateral flow immunoassay strips
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7127147/
https://www.ncbi.nlm.nih.gov/pubmed/32288251
http://dx.doi.org/10.1016/j.snb.2018.03.110
work_keys_str_mv AT xiaowei asimpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips
AT huangcaihong asimpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips
AT xufei asimpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips
AT yanjunjie asimpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips
AT bianhongfen asimpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips
AT fuqiangqiang asimpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips
AT xiekaixin asimpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips
AT wanglei asimpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips
AT tangyong asimpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips
AT xiaowei simpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips
AT huangcaihong simpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips
AT xufei simpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips
AT yanjunjie simpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips
AT bianhongfen simpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips
AT fuqiangqiang simpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips
AT xiekaixin simpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips
AT wanglei simpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips
AT tangyong simpleandcompactsmartphonebaseddeviceforthequantitativereadoutofcolloidalgoldlateralflowimmunoassaystrips