Cylinder Axis Agreement: Unexpected Scenarios

BACKGROUND: The purpose of this retrospective study was to evaluate cylinder axis agreement between manifest refraction (MR), cycloplegic refraction (CR), Allegro Oculyzer ІІ and Allegro Topolyzer-Vario. METHODS: We included 82 patients (32 males and 50 females, 28.1 ± 8.7 years old), with 156 eyes...

Descripción completa

Detalles Bibliográficos
Autor principal: Nabil, Karim Mahmoud
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7127776/
https://www.ncbi.nlm.nih.gov/pubmed/32280192
http://dx.doi.org/10.2147/OPTH.S237757
_version_ 1783516433670471680
author Nabil, Karim Mahmoud
author_facet Nabil, Karim Mahmoud
author_sort Nabil, Karim Mahmoud
collection PubMed
description BACKGROUND: The purpose of this retrospective study was to evaluate cylinder axis agreement between manifest refraction (MR), cycloplegic refraction (CR), Allegro Oculyzer ІІ and Allegro Topolyzer-Vario. METHODS: We included 82 patients (32 males and 50 females, 28.1 ± 8.7 years old), with 156 eyes scheduled for wavefront optimized laser refractive surgery, photorefractive keratectomy (PRK) in 50 eyes and laser-assisted in situ keratomileusis (LASIK) in 106 eyes, for correction of simple, myopic, hyperopic or mixed astigmatism. Cylinder axis was determined under manifest and cycloplegic refractions and using Allegro Occulyzer ІІ and Allegro Topolyzer-Vario platforms. Cylinder axis agreement was assessed by intraclass correlation coefficient, Pearson correlation coefficient and by the method described by Bland and Altman. RESULTS: Intraclass correlation coefficient and Pearson correlation coefficient showed statistically significant cylinder axis agreement between manifest refraction, cycloplegic refraction, Allegro Oculyzer ІІ and Allegro Topolyzer-Vario (p <0.001). Despite statistically significant cylinder axis agreement between the four measuring tools, 4 of 156 eyes (2.5%) showed unexpected discrepancy between Allegro Oculyzer ІІ and Allegro Topolyzer-Vario cylinder axis. CONCLUSION: Although cylinder axis shows statistically significant agreement between manifest refraction, cycloplegic refraction, Allegro Oculyzer ІІ and Allegro Topolyzer-Vario, unexpected discrepancies occur.
format Online
Article
Text
id pubmed-7127776
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-71277762020-04-10 Cylinder Axis Agreement: Unexpected Scenarios Nabil, Karim Mahmoud Clin Ophthalmol Original Research BACKGROUND: The purpose of this retrospective study was to evaluate cylinder axis agreement between manifest refraction (MR), cycloplegic refraction (CR), Allegro Oculyzer ІІ and Allegro Topolyzer-Vario. METHODS: We included 82 patients (32 males and 50 females, 28.1 ± 8.7 years old), with 156 eyes scheduled for wavefront optimized laser refractive surgery, photorefractive keratectomy (PRK) in 50 eyes and laser-assisted in situ keratomileusis (LASIK) in 106 eyes, for correction of simple, myopic, hyperopic or mixed astigmatism. Cylinder axis was determined under manifest and cycloplegic refractions and using Allegro Occulyzer ІІ and Allegro Topolyzer-Vario platforms. Cylinder axis agreement was assessed by intraclass correlation coefficient, Pearson correlation coefficient and by the method described by Bland and Altman. RESULTS: Intraclass correlation coefficient and Pearson correlation coefficient showed statistically significant cylinder axis agreement between manifest refraction, cycloplegic refraction, Allegro Oculyzer ІІ and Allegro Topolyzer-Vario (p <0.001). Despite statistically significant cylinder axis agreement between the four measuring tools, 4 of 156 eyes (2.5%) showed unexpected discrepancy between Allegro Oculyzer ІІ and Allegro Topolyzer-Vario cylinder axis. CONCLUSION: Although cylinder axis shows statistically significant agreement between manifest refraction, cycloplegic refraction, Allegro Oculyzer ІІ and Allegro Topolyzer-Vario, unexpected discrepancies occur. Dove 2020-03-31 /pmc/articles/PMC7127776/ /pubmed/32280192 http://dx.doi.org/10.2147/OPTH.S237757 Text en © 2020 Nabil. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Nabil, Karim Mahmoud
Cylinder Axis Agreement: Unexpected Scenarios
title Cylinder Axis Agreement: Unexpected Scenarios
title_full Cylinder Axis Agreement: Unexpected Scenarios
title_fullStr Cylinder Axis Agreement: Unexpected Scenarios
title_full_unstemmed Cylinder Axis Agreement: Unexpected Scenarios
title_short Cylinder Axis Agreement: Unexpected Scenarios
title_sort cylinder axis agreement: unexpected scenarios
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7127776/
https://www.ncbi.nlm.nih.gov/pubmed/32280192
http://dx.doi.org/10.2147/OPTH.S237757
work_keys_str_mv AT nabilkarimmahmoud cylinderaxisagreementunexpectedscenarios