Biological Mesh Repair of a Large Incisional Hernia Containing a Kidney Transplant in the Presence of Inflammation

The incidence of incisional hernia after kidney transplantation varies between 1.1% and 3.8%. These are usually repaired electively using polypropylene mesh. We present here a case where a patient presented as an emergency, with a large painful incisional hernia over his kidney transplant, and evide...

Descripción completa

Detalles Bibliográficos
Autores principales: Sran, Harkiran, Manook, Miriam, Chandak, Pankaj, Uwechue, Raphael, Drage, Martin, Loukopoulos, Ioannis, Kessaris, Nicos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7128063/
https://www.ncbi.nlm.nih.gov/pubmed/32309006
http://dx.doi.org/10.1155/2020/5675613
Descripción
Sumario:The incidence of incisional hernia after kidney transplantation varies between 1.1% and 3.8%. These are usually repaired electively using polypropylene mesh. We present here a case where a patient presented as an emergency, with a large painful incisional hernia over his kidney transplant, and evidence of local erythema and systemic inflammation. As this could have represented either infection or rejection, the patient was started on antibiotics and subsequently underwent graft nephrectomy and hernia repair using a biological (porcine-derived) acellular dermal matrix, Strattice™, with a satisfactory outcome. In addition, histology showed evidence of allograft rejection. This is the first reported case of an incisional hernia containing a rejecting kidney allograft, managed with nephrectomy and biological mesh repair.