Cargando…
Evaluation of Anyplex™ II RV16 and RB5 real-time RT-PCR compared to Seeplex(®) RV15 OneStep ACE and PneumoBacter ACE for the simultaneous detection of upper respiratory pathogens
This prospective study was performed to evaluate and compare the performance of the multiplex PCR Seeplex(®) assays and Anyplex™ II assays. From May 2014 until April 2016, a total of 247 respiratory samples were collected in Okinawa, Japan. Multiple respiratory pathogens were detected in 37% of pati...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd.
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7128259/ https://www.ncbi.nlm.nih.gov/pubmed/28830668 http://dx.doi.org/10.1016/j.jiac.2017.07.013 |
Sumario: | This prospective study was performed to evaluate and compare the performance of the multiplex PCR Seeplex(®) assays and Anyplex™ II assays. From May 2014 until April 2016, a total of 247 respiratory samples were collected in Okinawa, Japan. Multiple respiratory pathogens were detected in 37% of patients with positive results. The most prevalent pathogens were influenza A virus and respiratory syncytial virus B. Despite minor differences in capabilities, both the Seeplex(®) assays and Anyplex™ II assays can be easily implemented in diagnostic or research laboratories to optimize the detection and management of respiratory pathogen induced diseases. |
---|