Cargando…
Multiplex PCR system for the rapid diagnosis of respiratory virus infection: systematic review and meta-analysis
OBJECTIVES: To provide a summary of evidence for the diagnostic accuracies of three multiplex PCR systems (mPCRs)—BioFire FilmArray RP (FilmArray), Nanosphere Verigene RV+ test (Verigene RV+) and Hologic Gen-Probe Prodesse assays—on the detection of viral respiratory infections. METHODS: A comprehen...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7128951/ https://www.ncbi.nlm.nih.gov/pubmed/29208560 http://dx.doi.org/10.1016/j.cmi.2017.11.018 |
_version_ | 1783516679052984320 |
---|---|
author | Huang, H.-S. Tsai, C.-L. Chang, J. Hsu, T.-C. Lin, S. Lee, C.-C. |
author_facet | Huang, H.-S. Tsai, C.-L. Chang, J. Hsu, T.-C. Lin, S. Lee, C.-C. |
author_sort | Huang, H.-S. |
collection | PubMed |
description | OBJECTIVES: To provide a summary of evidence for the diagnostic accuracies of three multiplex PCR systems (mPCRs)—BioFire FilmArray RP (FilmArray), Nanosphere Verigene RV+ test (Verigene RV+) and Hologic Gen-Probe Prodesse assays—on the detection of viral respiratory infections. METHODS: A comprehensive search up to 1 July 2017 was conducted on Medline and Embase for studies that utilized FilmArray, Verigene RV+ and Prodesse for diagnosis of viral respiratory infections. A summary of diagnostic accuracies for the following five viruses were calculated: influenza A virus (FluA), influenza B virus, respiratory syncytial virus, human metapneumovirus and adenovirus. Hierarchical summary receiver operating curves were used for estimating the viral detection performance per assay. RESULTS: Twenty studies of 5510 patient samples were eligible for analysis. Multiplex PCRs demonstrated high diagnostic accuracy, with area under the receiver operating characteristic curve (AUROC) equal to or more than 0.98 for all the above viruses except for adenovirus (AUROC 0.89). FilmArray, Verigene RV+ and ProFlu+ (the only Prodesse assay with enough data) demonstrated a summary sensitivity for FluA of 0.911 (95% confidence interval, 0.848–0.949), 0.949 (95% confidence interval, 0.882–0.979) and 0.954 (95% confidence interval, 0.871–0.985), respectively. The three mPCRs were comparable in terms of detection of FluA. CONCLUSIONS: Point estimates calculated from eligible studies showed that the three mPCRs (FilmArray, Verigene RV+ and ProFlu+) are highly accurate and may provide important diagnostic information for early identification of respiratory virus infections. In patients with low pretest probability for FluA, these three mPCRs can predict a low possibility of infection and may justify withholding empirical antiviral treatments. |
format | Online Article Text |
id | pubmed-7128951 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. |
record_format | MEDLINE/PubMed |
spelling | pubmed-71289512020-04-08 Multiplex PCR system for the rapid diagnosis of respiratory virus infection: systematic review and meta-analysis Huang, H.-S. Tsai, C.-L. Chang, J. Hsu, T.-C. Lin, S. Lee, C.-C. Clin Microbiol Infect Article OBJECTIVES: To provide a summary of evidence for the diagnostic accuracies of three multiplex PCR systems (mPCRs)—BioFire FilmArray RP (FilmArray), Nanosphere Verigene RV+ test (Verigene RV+) and Hologic Gen-Probe Prodesse assays—on the detection of viral respiratory infections. METHODS: A comprehensive search up to 1 July 2017 was conducted on Medline and Embase for studies that utilized FilmArray, Verigene RV+ and Prodesse for diagnosis of viral respiratory infections. A summary of diagnostic accuracies for the following five viruses were calculated: influenza A virus (FluA), influenza B virus, respiratory syncytial virus, human metapneumovirus and adenovirus. Hierarchical summary receiver operating curves were used for estimating the viral detection performance per assay. RESULTS: Twenty studies of 5510 patient samples were eligible for analysis. Multiplex PCRs demonstrated high diagnostic accuracy, with area under the receiver operating characteristic curve (AUROC) equal to or more than 0.98 for all the above viruses except for adenovirus (AUROC 0.89). FilmArray, Verigene RV+ and ProFlu+ (the only Prodesse assay with enough data) demonstrated a summary sensitivity for FluA of 0.911 (95% confidence interval, 0.848–0.949), 0.949 (95% confidence interval, 0.882–0.979) and 0.954 (95% confidence interval, 0.871–0.985), respectively. The three mPCRs were comparable in terms of detection of FluA. CONCLUSIONS: Point estimates calculated from eligible studies showed that the three mPCRs (FilmArray, Verigene RV+ and ProFlu+) are highly accurate and may provide important diagnostic information for early identification of respiratory virus infections. In patients with low pretest probability for FluA, these three mPCRs can predict a low possibility of infection and may justify withholding empirical antiviral treatments. European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. 2018-10 2017-12-05 /pmc/articles/PMC7128951/ /pubmed/29208560 http://dx.doi.org/10.1016/j.cmi.2017.11.018 Text en © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Huang, H.-S. Tsai, C.-L. Chang, J. Hsu, T.-C. Lin, S. Lee, C.-C. Multiplex PCR system for the rapid diagnosis of respiratory virus infection: systematic review and meta-analysis |
title | Multiplex PCR system for the rapid diagnosis of respiratory virus infection: systematic review and meta-analysis |
title_full | Multiplex PCR system for the rapid diagnosis of respiratory virus infection: systematic review and meta-analysis |
title_fullStr | Multiplex PCR system for the rapid diagnosis of respiratory virus infection: systematic review and meta-analysis |
title_full_unstemmed | Multiplex PCR system for the rapid diagnosis of respiratory virus infection: systematic review and meta-analysis |
title_short | Multiplex PCR system for the rapid diagnosis of respiratory virus infection: systematic review and meta-analysis |
title_sort | multiplex pcr system for the rapid diagnosis of respiratory virus infection: systematic review and meta-analysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7128951/ https://www.ncbi.nlm.nih.gov/pubmed/29208560 http://dx.doi.org/10.1016/j.cmi.2017.11.018 |
work_keys_str_mv | AT huanghs multiplexpcrsystemfortherapiddiagnosisofrespiratoryvirusinfectionsystematicreviewandmetaanalysis AT tsaicl multiplexpcrsystemfortherapiddiagnosisofrespiratoryvirusinfectionsystematicreviewandmetaanalysis AT changj multiplexpcrsystemfortherapiddiagnosisofrespiratoryvirusinfectionsystematicreviewandmetaanalysis AT hsutc multiplexpcrsystemfortherapiddiagnosisofrespiratoryvirusinfectionsystematicreviewandmetaanalysis AT lins multiplexpcrsystemfortherapiddiagnosisofrespiratoryvirusinfectionsystematicreviewandmetaanalysis AT leecc multiplexpcrsystemfortherapiddiagnosisofrespiratoryvirusinfectionsystematicreviewandmetaanalysis |