Positioning an ECG electrode to the dorsal side can record higher amplitude of CMAPs during cryoballoon ablation

PURPOSE: Phrenic nerve injury (PNI) is one of the important complications during cryoballoon (CB) ablation. Recording diaphragmatic compound motor action potentials (CMAPs) during CB ablation can predict PNI. CMAP monitoring may be inaccurate when CMAP amplitudes are low. We examined the effect of p...

Descripción completa

Detalles Bibliográficos
Autores principales: Mizukami, Kazuya, Homma, Tsuneaki, Natsui, Hiroyuki, Kato, Mizuki, Otsu, Keisuke, Takenaka, Takashi, Sato, Minoru
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7132177/
https://www.ncbi.nlm.nih.gov/pubmed/32256882
http://dx.doi.org/10.1002/joa3.12314
_version_ 1783517393771823104
author Mizukami, Kazuya
Homma, Tsuneaki
Natsui, Hiroyuki
Kato, Mizuki
Otsu, Keisuke
Takenaka, Takashi
Sato, Minoru
author_facet Mizukami, Kazuya
Homma, Tsuneaki
Natsui, Hiroyuki
Kato, Mizuki
Otsu, Keisuke
Takenaka, Takashi
Sato, Minoru
author_sort Mizukami, Kazuya
collection PubMed
description PURPOSE: Phrenic nerve injury (PNI) is one of the important complications during cryoballoon (CB) ablation. Recording diaphragmatic compound motor action potentials (CMAPs) during CB ablation can predict PNI. CMAP monitoring may be inaccurate when CMAP amplitudes are low. We examined the effect of positioning an electrocardiography (ECG) electrode at the dorsal side. METHODS: We retrospectively analyzed the cases of 197 consecutive patients who underwent CB ablation for pulmonary vein isolation (PVI) (April 2016 to December 2018) at our institution. CMAP amplitudes were monitored using two recording methods just before cryoapplication. (a) Conventional method: right‐arm ECG electrode positioned 5 cm above the xiphoid on the ventral side; left‐arm ECG electrode positioned along the costal margin. (b) Our original method: right‐arm electrode positioned 5 cm above the xiphoid on the dorsal side; left‐arm electrode positioned along the costal margin. RESULTS: The CMAP amplitude during right phrenic nerve pacing was significantly higher at the dorsal side than the ventral side (0.80 ± 0.31 mV vs 0.66 ± 0.29 mV, P < .01). Similarly, the CMAP amplitude during left phrenic nerve pacing was significantly higher at the dorsal side than the ventral side (0.92 ± 0.39 mV, 0.73 ± 0.37 mV, P < .01). PNI occurred in six patients (3.0%); three patients experienced transient PNI, another three patients experienced persistent PNI, and none developed permanent PNI. CONCLUSIONS: CMAP amplitudes were significantly high at the dorsal side compared to the ventral side. Monitoring phrenic nerve function using an ECG electrode at the dorsal side is a simple and easy procedure.
format Online
Article
Text
id pubmed-7132177
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-71321772020-04-06 Positioning an ECG electrode to the dorsal side can record higher amplitude of CMAPs during cryoballoon ablation Mizukami, Kazuya Homma, Tsuneaki Natsui, Hiroyuki Kato, Mizuki Otsu, Keisuke Takenaka, Takashi Sato, Minoru J Arrhythm Original Articles PURPOSE: Phrenic nerve injury (PNI) is one of the important complications during cryoballoon (CB) ablation. Recording diaphragmatic compound motor action potentials (CMAPs) during CB ablation can predict PNI. CMAP monitoring may be inaccurate when CMAP amplitudes are low. We examined the effect of positioning an electrocardiography (ECG) electrode at the dorsal side. METHODS: We retrospectively analyzed the cases of 197 consecutive patients who underwent CB ablation for pulmonary vein isolation (PVI) (April 2016 to December 2018) at our institution. CMAP amplitudes were monitored using two recording methods just before cryoapplication. (a) Conventional method: right‐arm ECG electrode positioned 5 cm above the xiphoid on the ventral side; left‐arm ECG electrode positioned along the costal margin. (b) Our original method: right‐arm electrode positioned 5 cm above the xiphoid on the dorsal side; left‐arm electrode positioned along the costal margin. RESULTS: The CMAP amplitude during right phrenic nerve pacing was significantly higher at the dorsal side than the ventral side (0.80 ± 0.31 mV vs 0.66 ± 0.29 mV, P < .01). Similarly, the CMAP amplitude during left phrenic nerve pacing was significantly higher at the dorsal side than the ventral side (0.92 ± 0.39 mV, 0.73 ± 0.37 mV, P < .01). PNI occurred in six patients (3.0%); three patients experienced transient PNI, another three patients experienced persistent PNI, and none developed permanent PNI. CONCLUSIONS: CMAP amplitudes were significantly high at the dorsal side compared to the ventral side. Monitoring phrenic nerve function using an ECG electrode at the dorsal side is a simple and easy procedure. John Wiley and Sons Inc. 2020-02-13 /pmc/articles/PMC7132177/ /pubmed/32256882 http://dx.doi.org/10.1002/joa3.12314 Text en © 2020 The Authors. Journal of Arrhythmia published by John Wiley & Sons Australia, Ltd on behalf of the Japanese Heart Rhythm Society. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Mizukami, Kazuya
Homma, Tsuneaki
Natsui, Hiroyuki
Kato, Mizuki
Otsu, Keisuke
Takenaka, Takashi
Sato, Minoru
Positioning an ECG electrode to the dorsal side can record higher amplitude of CMAPs during cryoballoon ablation
title Positioning an ECG electrode to the dorsal side can record higher amplitude of CMAPs during cryoballoon ablation
title_full Positioning an ECG electrode to the dorsal side can record higher amplitude of CMAPs during cryoballoon ablation
title_fullStr Positioning an ECG electrode to the dorsal side can record higher amplitude of CMAPs during cryoballoon ablation
title_full_unstemmed Positioning an ECG electrode to the dorsal side can record higher amplitude of CMAPs during cryoballoon ablation
title_short Positioning an ECG electrode to the dorsal side can record higher amplitude of CMAPs during cryoballoon ablation
title_sort positioning an ecg electrode to the dorsal side can record higher amplitude of cmaps during cryoballoon ablation
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7132177/
https://www.ncbi.nlm.nih.gov/pubmed/32256882
http://dx.doi.org/10.1002/joa3.12314
work_keys_str_mv AT mizukamikazuya positioninganecgelectrodetothedorsalsidecanrecordhigheramplitudeofcmapsduringcryoballoonablation
AT hommatsuneaki positioninganecgelectrodetothedorsalsidecanrecordhigheramplitudeofcmapsduringcryoballoonablation
AT natsuihiroyuki positioninganecgelectrodetothedorsalsidecanrecordhigheramplitudeofcmapsduringcryoballoonablation
AT katomizuki positioninganecgelectrodetothedorsalsidecanrecordhigheramplitudeofcmapsduringcryoballoonablation
AT otsukeisuke positioninganecgelectrodetothedorsalsidecanrecordhigheramplitudeofcmapsduringcryoballoonablation
AT takenakatakashi positioninganecgelectrodetothedorsalsidecanrecordhigheramplitudeofcmapsduringcryoballoonablation
AT satominoru positioninganecgelectrodetothedorsalsidecanrecordhigheramplitudeofcmapsduringcryoballoonablation