A novel ophthalmic viscosurgical device-free phakic intraocular lens implantation makes myopic surgery safer
PURPOSE: To assess the efficacy and safety of a novel ophthalmic viscosurgical device-free (OVD-free) method for posterior chamber phakic intraocular lens (PIOL) implantation in myopic eyes. METHODS: In this retrospective cohort study, the medical records of myopic eyes that underwent PIOL (Implanta...
Autores principales: | Pan, An-Peng, Wen, Li-Jin, Shao, Xu, Zhou, Kai-Jing, Wang, Qin-Mei, Qu, Jia, Yu, A-Yong |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7137322/ https://www.ncbi.nlm.nih.gov/pubmed/32280722 http://dx.doi.org/10.1186/s40662-020-00185-4 |
Ejemplares similares
-
Comparison of two techniques for toric intraocular lens implantation: hydroimplantation versus ophthalmic viscosurgical devices
por: Chen, Yueqin, et al.
Publicado: (2018) -
Ophthalmic viscosurgical device backflow into cartridge during intraocular lens insertion using injectors
por: Matsuura, Kazuki, et al.
Publicado: (2014) -
Pure ICL Implantation: A Novel Ophthalmic Viscosurgical Device-Free Method
por: Qin, Qin, et al.
Publicado: (2021) -
Safety of implantable Collamer lens implantation without ophthalmic viscosurgical device: A retrospective cohort study
por: Peng, Manqiang, et al.
Publicado: (2020) -
Etiology and Management of Raised Intraocular Pressure following Posterior Chamber Phakic Intraocular Lens Implantation in Myopic Eyes
por: Senthil, Sirisha, et al.
Publicado: (2016)