Organ Protection for Radical Debridement to Prevent Recurrence of Infection after Zone 1 Thoracic Endovascular Aortic Aneurysm Repair: A Case Report

We present the case of a 73-year-old man with stent graft infection, who had undergone thoracic endovascular aortic aneurysm repair with a supra-aortic bypass from the right axillary to the left common carotid and axillary arteries. The procedure included total stent graft removal, radical debrideme...

Descripción completa

Detalles Bibliográficos
Autores principales: Koda, Yojiro, Murakami, Hirohisa, Matsuda, Hitoshi, Mukohara, Nobuhiko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7140163/
https://www.ncbi.nlm.nih.gov/pubmed/32273933
http://dx.doi.org/10.3400/avd.cr.19-00116
_version_ 1783518933140111360
author Koda, Yojiro
Murakami, Hirohisa
Matsuda, Hitoshi
Mukohara, Nobuhiko
author_facet Koda, Yojiro
Murakami, Hirohisa
Matsuda, Hitoshi
Mukohara, Nobuhiko
author_sort Koda, Yojiro
collection PubMed
description We present the case of a 73-year-old man with stent graft infection, who had undergone thoracic endovascular aortic aneurysm repair with a supra-aortic bypass from the right axillary to the left common carotid and axillary arteries. The procedure included total stent graft removal, radical debridement, and in situ graft replacement via left anterolateral thoracotomy. Cerebral perfusion from the left axillary artery and cardioplegia using an occlusion balloon with moderate hypothermia were performed to reinforce organ protection. Staged omentopexy was performed the next day after initial replacement with non-contaminated instruments. The postoperative course was uneventful. No recurrence of infection has been found for 3 years.
format Online
Article
Text
id pubmed-7140163
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology
record_format MEDLINE/PubMed
spelling pubmed-71401632020-04-09 Organ Protection for Radical Debridement to Prevent Recurrence of Infection after Zone 1 Thoracic Endovascular Aortic Aneurysm Repair: A Case Report Koda, Yojiro Murakami, Hirohisa Matsuda, Hitoshi Mukohara, Nobuhiko Ann Vasc Dis Case Report We present the case of a 73-year-old man with stent graft infection, who had undergone thoracic endovascular aortic aneurysm repair with a supra-aortic bypass from the right axillary to the left common carotid and axillary arteries. The procedure included total stent graft removal, radical debridement, and in situ graft replacement via left anterolateral thoracotomy. Cerebral perfusion from the left axillary artery and cardioplegia using an occlusion balloon with moderate hypothermia were performed to reinforce organ protection. Staged omentopexy was performed the next day after initial replacement with non-contaminated instruments. The postoperative course was uneventful. No recurrence of infection has been found for 3 years. Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology 2020-03-25 /pmc/articles/PMC7140163/ /pubmed/32273933 http://dx.doi.org/10.3400/avd.cr.19-00116 Text en Copyright © 2020 Annals of Vascular Diseases http://creativecommons.org/licenses/by-nc-sa/4.0/ ©2020 The Editorial Committee of Annals of Vascular Diseases. This article is distributed under the terms of the Creative Commons Attribution License, which permits use, distribution, and reproduction in any medium, provided the credit of the original work, a link to the license, and indication of any change are properly given, and the original work is not used for commercial purposes. Remixed or transformed contributions must be distributed under the same license as the original.
spellingShingle Case Report
Koda, Yojiro
Murakami, Hirohisa
Matsuda, Hitoshi
Mukohara, Nobuhiko
Organ Protection for Radical Debridement to Prevent Recurrence of Infection after Zone 1 Thoracic Endovascular Aortic Aneurysm Repair: A Case Report
title Organ Protection for Radical Debridement to Prevent Recurrence of Infection after Zone 1 Thoracic Endovascular Aortic Aneurysm Repair: A Case Report
title_full Organ Protection for Radical Debridement to Prevent Recurrence of Infection after Zone 1 Thoracic Endovascular Aortic Aneurysm Repair: A Case Report
title_fullStr Organ Protection for Radical Debridement to Prevent Recurrence of Infection after Zone 1 Thoracic Endovascular Aortic Aneurysm Repair: A Case Report
title_full_unstemmed Organ Protection for Radical Debridement to Prevent Recurrence of Infection after Zone 1 Thoracic Endovascular Aortic Aneurysm Repair: A Case Report
title_short Organ Protection for Radical Debridement to Prevent Recurrence of Infection after Zone 1 Thoracic Endovascular Aortic Aneurysm Repair: A Case Report
title_sort organ protection for radical debridement to prevent recurrence of infection after zone 1 thoracic endovascular aortic aneurysm repair: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7140163/
https://www.ncbi.nlm.nih.gov/pubmed/32273933
http://dx.doi.org/10.3400/avd.cr.19-00116
work_keys_str_mv AT kodayojiro organprotectionforradicaldebridementtopreventrecurrenceofinfectionafterzone1thoracicendovascularaorticaneurysmrepairacasereport
AT murakamihirohisa organprotectionforradicaldebridementtopreventrecurrenceofinfectionafterzone1thoracicendovascularaorticaneurysmrepairacasereport
AT matsudahitoshi organprotectionforradicaldebridementtopreventrecurrenceofinfectionafterzone1thoracicendovascularaorticaneurysmrepairacasereport
AT mukoharanobuhiko organprotectionforradicaldebridementtopreventrecurrenceofinfectionafterzone1thoracicendovascularaorticaneurysmrepairacasereport