Cargando…

Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction

OBJECTIVE: We aimed to compare the multi-marker strategy (copeptin and high-sensitivity cardiac troponin I [hs-cTnI]) with serial hs-cTnI measurements to rule out acute myocardial infarction (AMI) in patients with chest pain. METHODS: This prospective observational study was performed in a single em...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Kyung Su, Suh, Gil Joon, Song, Sang Hoon, Jung, Yoon Sun, Kim, Taegyun, Shin, So Mi, Kang, Min Woo, Lee, Min Sung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Emergency Medicine 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7141983/
https://www.ncbi.nlm.nih.gov/pubmed/32252132
http://dx.doi.org/10.15441/ceem.19.013
_version_ 1783519283946455040
author Kim, Kyung Su
Suh, Gil Joon
Song, Sang Hoon
Jung, Yoon Sun
Kim, Taegyun
Shin, So Mi
Kang, Min Woo
Lee, Min Sung
author_facet Kim, Kyung Su
Suh, Gil Joon
Song, Sang Hoon
Jung, Yoon Sun
Kim, Taegyun
Shin, So Mi
Kang, Min Woo
Lee, Min Sung
author_sort Kim, Kyung Su
collection PubMed
description OBJECTIVE: We aimed to compare the multi-marker strategy (copeptin and high-sensitivity cardiac troponin I [hs-cTnI]) with serial hs-cTnI measurements to rule out acute myocardial infarction (AMI) in patients with chest pain. METHODS: This prospective observational study was performed in a single emergency department. To test the non-inferiority margin of 4% in terms of negative predictive value (NPV) between the multi-marker strategy (0 hour) and serial hs-cTnI measurements (0 and 2 hours), 262 participants were required. Samples for copeptin and hs-cTnI assays were collected at presentation (0 hour) and after 2 hours. The measured biomarkers were considered abnormal when hs-cTnI was >26.2 ng/L and when copeptin was >10 pmol/L. RESULTS: AMI was diagnosed in 28 patients (10.7%). The NPV of the multi-marker strategy was 100% (160/160; 95% confidence interval [CI], 97.7% to 100%), which was not inferior to that of serial hs-cTnI measurements (201/201; 100%; 95% CI, 98.2% to 100%). The sensitivity, specificity, and positive predictive value of the multi-marker strategy were 100% (95% CI, 87.7% to 100%), 68.1% (95% CI, 61.7% to 74.0%), and 27.2% (95% CI, 18.9% to 36.8%), respectively. The sensitivity, specificity, and positive predictive value of serial hs-cTnI measurements were 100% (95% CI, 87.7% to 100%), 85.5% (95% CI, 80.4% to 89.8%), and 45.2% (95% CI, 32.5% to 58.3%), respectively. CONCLUSION: The multi-marker strategy (copeptin and hs-cTnI measurement) was not inferior to serial hs-cTnI measurements in terms of NPV for AMI diagnosis, with a sensitivity and NPV of 100%. Copeptin may help in the early rule-out of AMI in patients with chest pain.
format Online
Article
Text
id pubmed-7141983
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Korean Society of Emergency Medicine
record_format MEDLINE/PubMed
spelling pubmed-71419832020-04-13 Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction Kim, Kyung Su Suh, Gil Joon Song, Sang Hoon Jung, Yoon Sun Kim, Taegyun Shin, So Mi Kang, Min Woo Lee, Min Sung Clin Exp Emerg Med Original Article OBJECTIVE: We aimed to compare the multi-marker strategy (copeptin and high-sensitivity cardiac troponin I [hs-cTnI]) with serial hs-cTnI measurements to rule out acute myocardial infarction (AMI) in patients with chest pain. METHODS: This prospective observational study was performed in a single emergency department. To test the non-inferiority margin of 4% in terms of negative predictive value (NPV) between the multi-marker strategy (0 hour) and serial hs-cTnI measurements (0 and 2 hours), 262 participants were required. Samples for copeptin and hs-cTnI assays were collected at presentation (0 hour) and after 2 hours. The measured biomarkers were considered abnormal when hs-cTnI was >26.2 ng/L and when copeptin was >10 pmol/L. RESULTS: AMI was diagnosed in 28 patients (10.7%). The NPV of the multi-marker strategy was 100% (160/160; 95% confidence interval [CI], 97.7% to 100%), which was not inferior to that of serial hs-cTnI measurements (201/201; 100%; 95% CI, 98.2% to 100%). The sensitivity, specificity, and positive predictive value of the multi-marker strategy were 100% (95% CI, 87.7% to 100%), 68.1% (95% CI, 61.7% to 74.0%), and 27.2% (95% CI, 18.9% to 36.8%), respectively. The sensitivity, specificity, and positive predictive value of serial hs-cTnI measurements were 100% (95% CI, 87.7% to 100%), 85.5% (95% CI, 80.4% to 89.8%), and 45.2% (95% CI, 32.5% to 58.3%), respectively. CONCLUSION: The multi-marker strategy (copeptin and hs-cTnI measurement) was not inferior to serial hs-cTnI measurements in terms of NPV for AMI diagnosis, with a sensitivity and NPV of 100%. Copeptin may help in the early rule-out of AMI in patients with chest pain. The Korean Society of Emergency Medicine 2020-03-31 /pmc/articles/PMC7141983/ /pubmed/32252132 http://dx.doi.org/10.15441/ceem.19.013 Text en Copyright © 2020 The Korean Society of Emergency Medicine This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/).
spellingShingle Original Article
Kim, Kyung Su
Suh, Gil Joon
Song, Sang Hoon
Jung, Yoon Sun
Kim, Taegyun
Shin, So Mi
Kang, Min Woo
Lee, Min Sung
Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction
title Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction
title_full Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction
title_fullStr Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction
title_full_unstemmed Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction
title_short Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction
title_sort copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7141983/
https://www.ncbi.nlm.nih.gov/pubmed/32252132
http://dx.doi.org/10.15441/ceem.19.013
work_keys_str_mv AT kimkyungsu copeptinwithhighsensitivitytroponinatpresentationisnotinferiortoserialtroponinmeasurementsforrulingoutacutemyocardialinfarction
AT suhgiljoon copeptinwithhighsensitivitytroponinatpresentationisnotinferiortoserialtroponinmeasurementsforrulingoutacutemyocardialinfarction
AT songsanghoon copeptinwithhighsensitivitytroponinatpresentationisnotinferiortoserialtroponinmeasurementsforrulingoutacutemyocardialinfarction
AT jungyoonsun copeptinwithhighsensitivitytroponinatpresentationisnotinferiortoserialtroponinmeasurementsforrulingoutacutemyocardialinfarction
AT kimtaegyun copeptinwithhighsensitivitytroponinatpresentationisnotinferiortoserialtroponinmeasurementsforrulingoutacutemyocardialinfarction
AT shinsomi copeptinwithhighsensitivitytroponinatpresentationisnotinferiortoserialtroponinmeasurementsforrulingoutacutemyocardialinfarction
AT kangminwoo copeptinwithhighsensitivitytroponinatpresentationisnotinferiortoserialtroponinmeasurementsforrulingoutacutemyocardialinfarction
AT leeminsung copeptinwithhighsensitivitytroponinatpresentationisnotinferiortoserialtroponinmeasurementsforrulingoutacutemyocardialinfarction