Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction
OBJECTIVE: We aimed to compare the multi-marker strategy (copeptin and high-sensitivity cardiac troponin I [hs-cTnI]) with serial hs-cTnI measurements to rule out acute myocardial infarction (AMI) in patients with chest pain. METHODS: This prospective observational study was performed in a single em...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Emergency Medicine
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7141983/ https://www.ncbi.nlm.nih.gov/pubmed/32252132 http://dx.doi.org/10.15441/ceem.19.013 |
_version_ | 1783519283946455040 |
---|---|
author | Kim, Kyung Su Suh, Gil Joon Song, Sang Hoon Jung, Yoon Sun Kim, Taegyun Shin, So Mi Kang, Min Woo Lee, Min Sung |
author_facet | Kim, Kyung Su Suh, Gil Joon Song, Sang Hoon Jung, Yoon Sun Kim, Taegyun Shin, So Mi Kang, Min Woo Lee, Min Sung |
author_sort | Kim, Kyung Su |
collection | PubMed |
description | OBJECTIVE: We aimed to compare the multi-marker strategy (copeptin and high-sensitivity cardiac troponin I [hs-cTnI]) with serial hs-cTnI measurements to rule out acute myocardial infarction (AMI) in patients with chest pain. METHODS: This prospective observational study was performed in a single emergency department. To test the non-inferiority margin of 4% in terms of negative predictive value (NPV) between the multi-marker strategy (0 hour) and serial hs-cTnI measurements (0 and 2 hours), 262 participants were required. Samples for copeptin and hs-cTnI assays were collected at presentation (0 hour) and after 2 hours. The measured biomarkers were considered abnormal when hs-cTnI was >26.2 ng/L and when copeptin was >10 pmol/L. RESULTS: AMI was diagnosed in 28 patients (10.7%). The NPV of the multi-marker strategy was 100% (160/160; 95% confidence interval [CI], 97.7% to 100%), which was not inferior to that of serial hs-cTnI measurements (201/201; 100%; 95% CI, 98.2% to 100%). The sensitivity, specificity, and positive predictive value of the multi-marker strategy were 100% (95% CI, 87.7% to 100%), 68.1% (95% CI, 61.7% to 74.0%), and 27.2% (95% CI, 18.9% to 36.8%), respectively. The sensitivity, specificity, and positive predictive value of serial hs-cTnI measurements were 100% (95% CI, 87.7% to 100%), 85.5% (95% CI, 80.4% to 89.8%), and 45.2% (95% CI, 32.5% to 58.3%), respectively. CONCLUSION: The multi-marker strategy (copeptin and hs-cTnI measurement) was not inferior to serial hs-cTnI measurements in terms of NPV for AMI diagnosis, with a sensitivity and NPV of 100%. Copeptin may help in the early rule-out of AMI in patients with chest pain. |
format | Online Article Text |
id | pubmed-7141983 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | The Korean Society of Emergency Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-71419832020-04-13 Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction Kim, Kyung Su Suh, Gil Joon Song, Sang Hoon Jung, Yoon Sun Kim, Taegyun Shin, So Mi Kang, Min Woo Lee, Min Sung Clin Exp Emerg Med Original Article OBJECTIVE: We aimed to compare the multi-marker strategy (copeptin and high-sensitivity cardiac troponin I [hs-cTnI]) with serial hs-cTnI measurements to rule out acute myocardial infarction (AMI) in patients with chest pain. METHODS: This prospective observational study was performed in a single emergency department. To test the non-inferiority margin of 4% in terms of negative predictive value (NPV) between the multi-marker strategy (0 hour) and serial hs-cTnI measurements (0 and 2 hours), 262 participants were required. Samples for copeptin and hs-cTnI assays were collected at presentation (0 hour) and after 2 hours. The measured biomarkers were considered abnormal when hs-cTnI was >26.2 ng/L and when copeptin was >10 pmol/L. RESULTS: AMI was diagnosed in 28 patients (10.7%). The NPV of the multi-marker strategy was 100% (160/160; 95% confidence interval [CI], 97.7% to 100%), which was not inferior to that of serial hs-cTnI measurements (201/201; 100%; 95% CI, 98.2% to 100%). The sensitivity, specificity, and positive predictive value of the multi-marker strategy were 100% (95% CI, 87.7% to 100%), 68.1% (95% CI, 61.7% to 74.0%), and 27.2% (95% CI, 18.9% to 36.8%), respectively. The sensitivity, specificity, and positive predictive value of serial hs-cTnI measurements were 100% (95% CI, 87.7% to 100%), 85.5% (95% CI, 80.4% to 89.8%), and 45.2% (95% CI, 32.5% to 58.3%), respectively. CONCLUSION: The multi-marker strategy (copeptin and hs-cTnI measurement) was not inferior to serial hs-cTnI measurements in terms of NPV for AMI diagnosis, with a sensitivity and NPV of 100%. Copeptin may help in the early rule-out of AMI in patients with chest pain. The Korean Society of Emergency Medicine 2020-03-31 /pmc/articles/PMC7141983/ /pubmed/32252132 http://dx.doi.org/10.15441/ceem.19.013 Text en Copyright © 2020 The Korean Society of Emergency Medicine This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/). |
spellingShingle | Original Article Kim, Kyung Su Suh, Gil Joon Song, Sang Hoon Jung, Yoon Sun Kim, Taegyun Shin, So Mi Kang, Min Woo Lee, Min Sung Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction |
title | Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction |
title_full | Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction |
title_fullStr | Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction |
title_full_unstemmed | Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction |
title_short | Copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction |
title_sort | copeptin with high-sensitivity troponin at presentation is not inferior to serial troponin measurements for ruling out acute myocardial infarction |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7141983/ https://www.ncbi.nlm.nih.gov/pubmed/32252132 http://dx.doi.org/10.15441/ceem.19.013 |
work_keys_str_mv | AT kimkyungsu copeptinwithhighsensitivitytroponinatpresentationisnotinferiortoserialtroponinmeasurementsforrulingoutacutemyocardialinfarction AT suhgiljoon copeptinwithhighsensitivitytroponinatpresentationisnotinferiortoserialtroponinmeasurementsforrulingoutacutemyocardialinfarction AT songsanghoon copeptinwithhighsensitivitytroponinatpresentationisnotinferiortoserialtroponinmeasurementsforrulingoutacutemyocardialinfarction AT jungyoonsun copeptinwithhighsensitivitytroponinatpresentationisnotinferiortoserialtroponinmeasurementsforrulingoutacutemyocardialinfarction AT kimtaegyun copeptinwithhighsensitivitytroponinatpresentationisnotinferiortoserialtroponinmeasurementsforrulingoutacutemyocardialinfarction AT shinsomi copeptinwithhighsensitivitytroponinatpresentationisnotinferiortoserialtroponinmeasurementsforrulingoutacutemyocardialinfarction AT kangminwoo copeptinwithhighsensitivitytroponinatpresentationisnotinferiortoserialtroponinmeasurementsforrulingoutacutemyocardialinfarction AT leeminsung copeptinwithhighsensitivitytroponinatpresentationisnotinferiortoserialtroponinmeasurementsforrulingoutacutemyocardialinfarction |