Cargando…
Equipment for Testing Measuring Devices at a Low-Level Radon Activity Concentration
The National Institute for Nuclear, Biological, and Chemical Protection, under the European project 16ENV10 MetroRADON (the European metrology program for innovation and research, EMPIR), has developed unique equipment for the testing of measuring devices at low-level radon activity concentrations....
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7142911/ https://www.ncbi.nlm.nih.gov/pubmed/32183418 http://dx.doi.org/10.3390/ijerph17061904 |
_version_ | 1783519491468034048 |
---|---|
author | Fialova, Eliska Otahal, Petr P. S. Vosahlik, Josef Mazanova, Monika |
author_facet | Fialova, Eliska Otahal, Petr P. S. Vosahlik, Josef Mazanova, Monika |
author_sort | Fialova, Eliska |
collection | PubMed |
description | The National Institute for Nuclear, Biological, and Chemical Protection, under the European project 16ENV10 MetroRADON (the European metrology program for innovation and research, EMPIR), has developed unique equipment for the testing of measuring devices at low-level radon activity concentrations. The equipment consists particularly of an airtight low-level radon chamber (LLRCH) with an inner volume of 324 liters; a Rn-222 type RF 5 flow-through source with a Ra-226 activity of 4.955 kBq developed by Czech Metrological Institute within the above-mentioned project; and a pressure vessel as a radon-free air source. The mass flow controller of the Bronkhorst EL-Flow type is a part of the apparatus and ensures the requested airflow through the radon source—partialized if necessary—through the chamber. The homogeneity of the atmosphere in the chamber is ensured by means of a continuously regulated fan (airflows in the range of 0.1–3.5 m·s(−1) can be established). Another important chamber component is the measuring device of climatic conditions, since temperature, air pressure, and relative humidity must be determined. The construction of the equipment allows the time-stable radon activity concentration to be maintained at a precise level for several days. Radon concentration values can be arbitrarily and continuously set in the range from 100 Bq·m(−3) to 300 Bq·m(−3). |
format | Online Article Text |
id | pubmed-7142911 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-71429112020-04-14 Equipment for Testing Measuring Devices at a Low-Level Radon Activity Concentration Fialova, Eliska Otahal, Petr P. S. Vosahlik, Josef Mazanova, Monika Int J Environ Res Public Health Article The National Institute for Nuclear, Biological, and Chemical Protection, under the European project 16ENV10 MetroRADON (the European metrology program for innovation and research, EMPIR), has developed unique equipment for the testing of measuring devices at low-level radon activity concentrations. The equipment consists particularly of an airtight low-level radon chamber (LLRCH) with an inner volume of 324 liters; a Rn-222 type RF 5 flow-through source with a Ra-226 activity of 4.955 kBq developed by Czech Metrological Institute within the above-mentioned project; and a pressure vessel as a radon-free air source. The mass flow controller of the Bronkhorst EL-Flow type is a part of the apparatus and ensures the requested airflow through the radon source—partialized if necessary—through the chamber. The homogeneity of the atmosphere in the chamber is ensured by means of a continuously regulated fan (airflows in the range of 0.1–3.5 m·s(−1) can be established). Another important chamber component is the measuring device of climatic conditions, since temperature, air pressure, and relative humidity must be determined. The construction of the equipment allows the time-stable radon activity concentration to be maintained at a precise level for several days. Radon concentration values can be arbitrarily and continuously set in the range from 100 Bq·m(−3) to 300 Bq·m(−3). MDPI 2020-03-15 2020-03 /pmc/articles/PMC7142911/ /pubmed/32183418 http://dx.doi.org/10.3390/ijerph17061904 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Fialova, Eliska Otahal, Petr P. S. Vosahlik, Josef Mazanova, Monika Equipment for Testing Measuring Devices at a Low-Level Radon Activity Concentration |
title | Equipment for Testing Measuring Devices at a Low-Level Radon Activity Concentration |
title_full | Equipment for Testing Measuring Devices at a Low-Level Radon Activity Concentration |
title_fullStr | Equipment for Testing Measuring Devices at a Low-Level Radon Activity Concentration |
title_full_unstemmed | Equipment for Testing Measuring Devices at a Low-Level Radon Activity Concentration |
title_short | Equipment for Testing Measuring Devices at a Low-Level Radon Activity Concentration |
title_sort | equipment for testing measuring devices at a low-level radon activity concentration |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7142911/ https://www.ncbi.nlm.nih.gov/pubmed/32183418 http://dx.doi.org/10.3390/ijerph17061904 |
work_keys_str_mv | AT fialovaeliska equipmentfortestingmeasuringdevicesatalowlevelradonactivityconcentration AT otahalpetrps equipmentfortestingmeasuringdevicesatalowlevelradonactivityconcentration AT vosahlikjosef equipmentfortestingmeasuringdevicesatalowlevelradonactivityconcentration AT mazanovamonika equipmentfortestingmeasuringdevicesatalowlevelradonactivityconcentration |