Cargando…
Buoyancy-Free Janus Microcylinders as Mobile Microelectrode Arrays for Continuous Microfluidic Biomolecule Collection within a Wide Frequency Range: A Numerical Simulation Study
We numerically study herein the AC electrokinetic motion of Janus mobile microelectrode (ME) arrays in electrolyte solution in a wide field frequency, which holds great potential for biomedical applications. A fully coupled physical model, which incorporates the fluid-structure interaction under the...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7142959/ https://www.ncbi.nlm.nih.gov/pubmed/32164333 http://dx.doi.org/10.3390/mi11030289 |
_version_ | 1783519502715060224 |
---|---|
author | Liu, Weiyu Ren, Yukun Tao, Ye Yan, Hui Xiao, Congda Wu, Qisheng |
author_facet | Liu, Weiyu Ren, Yukun Tao, Ye Yan, Hui Xiao, Congda Wu, Qisheng |
author_sort | Liu, Weiyu |
collection | PubMed |
description | We numerically study herein the AC electrokinetic motion of Janus mobile microelectrode (ME) arrays in electrolyte solution in a wide field frequency, which holds great potential for biomedical applications. A fully coupled physical model, which incorporates the fluid-structure interaction under the synergy of induced-charge electroosmotic (ICEO) slipping and interfacial Maxwell stress, is developed for this purpose. A freely suspended Janus cylinder free from buoyancy, whose main body is made of polystyrene, while half of the particle surface is coated with a thin conducting film of negligible thickness, will react actively on application of an AC signal. In the low-frequency limit, induced-charge electrophoretic (ICEP) translation occurs due to symmetric breaking in ICEO slipping, which renders the insulating end to move ahead. At higher field frequencies, a brand-new electrokinetic transport phenomenon called “ego-dielectrophoresis (e-DEP)” arises due to the action of the localized uneven field on the inhomogeneous particle dipole moment. In stark contrast with the low-frequency ICEP translation, the high-frequency e-DEP force tends to drive the asymmetric dipole moment to move in the direction of the conducting end. The bidirectional transport feature of Janus microspheres in a wide AC frequency range can be vividly interpreted as an array of ME for continuous loading of secondary bioparticles from the surrounding liquid medium along its direction-controllable path by long-range electroconvection. These results pave the way for achieving flexible and high-throughput on-chip extraction of nanoscale biological contents for subsequent on-site bioassay based upon AC electrokinetics of Janus ME arrays. |
format | Online Article Text |
id | pubmed-7142959 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-71429592020-04-14 Buoyancy-Free Janus Microcylinders as Mobile Microelectrode Arrays for Continuous Microfluidic Biomolecule Collection within a Wide Frequency Range: A Numerical Simulation Study Liu, Weiyu Ren, Yukun Tao, Ye Yan, Hui Xiao, Congda Wu, Qisheng Micromachines (Basel) Article We numerically study herein the AC electrokinetic motion of Janus mobile microelectrode (ME) arrays in electrolyte solution in a wide field frequency, which holds great potential for biomedical applications. A fully coupled physical model, which incorporates the fluid-structure interaction under the synergy of induced-charge electroosmotic (ICEO) slipping and interfacial Maxwell stress, is developed for this purpose. A freely suspended Janus cylinder free from buoyancy, whose main body is made of polystyrene, while half of the particle surface is coated with a thin conducting film of negligible thickness, will react actively on application of an AC signal. In the low-frequency limit, induced-charge electrophoretic (ICEP) translation occurs due to symmetric breaking in ICEO slipping, which renders the insulating end to move ahead. At higher field frequencies, a brand-new electrokinetic transport phenomenon called “ego-dielectrophoresis (e-DEP)” arises due to the action of the localized uneven field on the inhomogeneous particle dipole moment. In stark contrast with the low-frequency ICEP translation, the high-frequency e-DEP force tends to drive the asymmetric dipole moment to move in the direction of the conducting end. The bidirectional transport feature of Janus microspheres in a wide AC frequency range can be vividly interpreted as an array of ME for continuous loading of secondary bioparticles from the surrounding liquid medium along its direction-controllable path by long-range electroconvection. These results pave the way for achieving flexible and high-throughput on-chip extraction of nanoscale biological contents for subsequent on-site bioassay based upon AC electrokinetics of Janus ME arrays. MDPI 2020-03-10 /pmc/articles/PMC7142959/ /pubmed/32164333 http://dx.doi.org/10.3390/mi11030289 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Liu, Weiyu Ren, Yukun Tao, Ye Yan, Hui Xiao, Congda Wu, Qisheng Buoyancy-Free Janus Microcylinders as Mobile Microelectrode Arrays for Continuous Microfluidic Biomolecule Collection within a Wide Frequency Range: A Numerical Simulation Study |
title | Buoyancy-Free Janus Microcylinders as Mobile Microelectrode Arrays for Continuous Microfluidic Biomolecule Collection within a Wide Frequency Range: A Numerical Simulation Study |
title_full | Buoyancy-Free Janus Microcylinders as Mobile Microelectrode Arrays for Continuous Microfluidic Biomolecule Collection within a Wide Frequency Range: A Numerical Simulation Study |
title_fullStr | Buoyancy-Free Janus Microcylinders as Mobile Microelectrode Arrays for Continuous Microfluidic Biomolecule Collection within a Wide Frequency Range: A Numerical Simulation Study |
title_full_unstemmed | Buoyancy-Free Janus Microcylinders as Mobile Microelectrode Arrays for Continuous Microfluidic Biomolecule Collection within a Wide Frequency Range: A Numerical Simulation Study |
title_short | Buoyancy-Free Janus Microcylinders as Mobile Microelectrode Arrays for Continuous Microfluidic Biomolecule Collection within a Wide Frequency Range: A Numerical Simulation Study |
title_sort | buoyancy-free janus microcylinders as mobile microelectrode arrays for continuous microfluidic biomolecule collection within a wide frequency range: a numerical simulation study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7142959/ https://www.ncbi.nlm.nih.gov/pubmed/32164333 http://dx.doi.org/10.3390/mi11030289 |
work_keys_str_mv | AT liuweiyu buoyancyfreejanusmicrocylindersasmobilemicroelectrodearraysforcontinuousmicrofluidicbiomoleculecollectionwithinawidefrequencyrangeanumericalsimulationstudy AT renyukun buoyancyfreejanusmicrocylindersasmobilemicroelectrodearraysforcontinuousmicrofluidicbiomoleculecollectionwithinawidefrequencyrangeanumericalsimulationstudy AT taoye buoyancyfreejanusmicrocylindersasmobilemicroelectrodearraysforcontinuousmicrofluidicbiomoleculecollectionwithinawidefrequencyrangeanumericalsimulationstudy AT yanhui buoyancyfreejanusmicrocylindersasmobilemicroelectrodearraysforcontinuousmicrofluidicbiomoleculecollectionwithinawidefrequencyrangeanumericalsimulationstudy AT xiaocongda buoyancyfreejanusmicrocylindersasmobilemicroelectrodearraysforcontinuousmicrofluidicbiomoleculecollectionwithinawidefrequencyrangeanumericalsimulationstudy AT wuqisheng buoyancyfreejanusmicrocylindersasmobilemicroelectrodearraysforcontinuousmicrofluidicbiomoleculecollectionwithinawidefrequencyrangeanumericalsimulationstudy |