Cargando…

Using Additives for Fouling Control in a Lab-Scale MBR; Comparing the Anti-Fouling Potential of Coagulants, PAC and Bio-Film Carriers

This study investigates the effect of different additives, such as coagulants/flocculants, adsorption agents (powdered activated carbon, PAC), and bio-film carriers, on the fouling propensity of a lab-scale membrane bio-reactor (MBR) treating synthetic municipal wastewater. The coagulation agents FO...

Descripción completa

Detalles Bibliográficos
Autores principales: Gkotsis, Petros, Zouboulis, Anastasios, Mitrakas, Manassis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7143806/
https://www.ncbi.nlm.nih.gov/pubmed/32178462
http://dx.doi.org/10.3390/membranes10030042
_version_ 1783519698337398784
author Gkotsis, Petros
Zouboulis, Anastasios
Mitrakas, Manassis
author_facet Gkotsis, Petros
Zouboulis, Anastasios
Mitrakas, Manassis
author_sort Gkotsis, Petros
collection PubMed
description This study investigates the effect of different additives, such as coagulants/flocculants, adsorption agents (powdered activated carbon, PAC), and bio-film carriers, on the fouling propensity of a lab-scale membrane bio-reactor (MBR) treating synthetic municipal wastewater. The coagulation agents FO 4350 SSH, Adifloc KD 451, and PAC1 A9-M at concentrations of 10 mg/L, 10 mg/L, and 100 mg Al/L, respectively, and PAC at a concentration of 3.6 ± 0.1 g/L, exhibited the best results during their batch-mode addition to biomass samples. The optimal additives FO 4350 SSH and Adifloc KD 451 were continuously added to the bioreactor at continuous-flow addition experiments and resulted in increased membrane lifetime by 16% and 13%, respectively, suggesting that the decrease of SMP(c) concentration and the increase of sludge filterability is the dominant fouling reduction mechanism. On the contrary, fouling reduction was low when PAC1 A9-M and PAC were continuously added, as the membrane lifetime was increased by approximately 6%. Interestingly, the addition of bio-film carriers (at filling ratios of 40%, 50%, and 60%) did not affect SMP(c) concentration, sludge filterability, and trans-membrane pressure (TMP). Finally, the effluent quality was satisfactory in terms of organics and ammonia removal, as chemical oxygen demand (COD), biochemical oxygen demand (BOD)(5), and NH [Formula: see text]-N concentrations were consistently below the permissible discharge limits and rarely exceeded 30, 15, and 0.9 mg/L, respectively.
format Online
Article
Text
id pubmed-7143806
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-71438062020-04-14 Using Additives for Fouling Control in a Lab-Scale MBR; Comparing the Anti-Fouling Potential of Coagulants, PAC and Bio-Film Carriers Gkotsis, Petros Zouboulis, Anastasios Mitrakas, Manassis Membranes (Basel) Article This study investigates the effect of different additives, such as coagulants/flocculants, adsorption agents (powdered activated carbon, PAC), and bio-film carriers, on the fouling propensity of a lab-scale membrane bio-reactor (MBR) treating synthetic municipal wastewater. The coagulation agents FO 4350 SSH, Adifloc KD 451, and PAC1 A9-M at concentrations of 10 mg/L, 10 mg/L, and 100 mg Al/L, respectively, and PAC at a concentration of 3.6 ± 0.1 g/L, exhibited the best results during their batch-mode addition to biomass samples. The optimal additives FO 4350 SSH and Adifloc KD 451 were continuously added to the bioreactor at continuous-flow addition experiments and resulted in increased membrane lifetime by 16% and 13%, respectively, suggesting that the decrease of SMP(c) concentration and the increase of sludge filterability is the dominant fouling reduction mechanism. On the contrary, fouling reduction was low when PAC1 A9-M and PAC were continuously added, as the membrane lifetime was increased by approximately 6%. Interestingly, the addition of bio-film carriers (at filling ratios of 40%, 50%, and 60%) did not affect SMP(c) concentration, sludge filterability, and trans-membrane pressure (TMP). Finally, the effluent quality was satisfactory in terms of organics and ammonia removal, as chemical oxygen demand (COD), biochemical oxygen demand (BOD)(5), and NH [Formula: see text]-N concentrations were consistently below the permissible discharge limits and rarely exceeded 30, 15, and 0.9 mg/L, respectively. MDPI 2020-03-12 /pmc/articles/PMC7143806/ /pubmed/32178462 http://dx.doi.org/10.3390/membranes10030042 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Gkotsis, Petros
Zouboulis, Anastasios
Mitrakas, Manassis
Using Additives for Fouling Control in a Lab-Scale MBR; Comparing the Anti-Fouling Potential of Coagulants, PAC and Bio-Film Carriers
title Using Additives for Fouling Control in a Lab-Scale MBR; Comparing the Anti-Fouling Potential of Coagulants, PAC and Bio-Film Carriers
title_full Using Additives for Fouling Control in a Lab-Scale MBR; Comparing the Anti-Fouling Potential of Coagulants, PAC and Bio-Film Carriers
title_fullStr Using Additives for Fouling Control in a Lab-Scale MBR; Comparing the Anti-Fouling Potential of Coagulants, PAC and Bio-Film Carriers
title_full_unstemmed Using Additives for Fouling Control in a Lab-Scale MBR; Comparing the Anti-Fouling Potential of Coagulants, PAC and Bio-Film Carriers
title_short Using Additives for Fouling Control in a Lab-Scale MBR; Comparing the Anti-Fouling Potential of Coagulants, PAC and Bio-Film Carriers
title_sort using additives for fouling control in a lab-scale mbr; comparing the anti-fouling potential of coagulants, pac and bio-film carriers
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7143806/
https://www.ncbi.nlm.nih.gov/pubmed/32178462
http://dx.doi.org/10.3390/membranes10030042
work_keys_str_mv AT gkotsispetros usingadditivesforfoulingcontrolinalabscalembrcomparingtheantifoulingpotentialofcoagulantspacandbiofilmcarriers
AT zouboulisanastasios usingadditivesforfoulingcontrolinalabscalembrcomparingtheantifoulingpotentialofcoagulantspacandbiofilmcarriers
AT mitrakasmanassis usingadditivesforfoulingcontrolinalabscalembrcomparingtheantifoulingpotentialofcoagulantspacandbiofilmcarriers