Cargando…

The frequency of reduction loss after arthroscopic fixation of acute acromioclavicular dislocations using a double-button device, and its effect on clinical and radiological results

BACKGROUND: The aim of this study was to investigate the effect of reduction loss of more than 3 mm on clinical and radiological results after at least 2 years of follow-up after arthroscopic fixation of acute acromioclavicular joint dislocations using a double-button device. METHODS: Thirty-six pat...

Descripción completa

Detalles Bibliográficos
Autores principales: Çarkçı, Engin, Polat, Ayşe Esin, Gürpınar, Tahsin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7144043/
https://www.ncbi.nlm.nih.gov/pubmed/32268914
http://dx.doi.org/10.1186/s13018-020-01674-x
_version_ 1783519755890589696
author Çarkçı, Engin
Polat, Ayşe Esin
Gürpınar, Tahsin
author_facet Çarkçı, Engin
Polat, Ayşe Esin
Gürpınar, Tahsin
author_sort Çarkçı, Engin
collection PubMed
description BACKGROUND: The aim of this study was to investigate the effect of reduction loss of more than 3 mm on clinical and radiological results after at least 2 years of follow-up after arthroscopic fixation of acute acromioclavicular joint dislocations using a double-button device. METHODS: Thirty-six patients who had acute (< 3 weeks old), type III or V acromioclavicular (AC) joint dislocations underwent arthroscopic fixation of the AC joint using a double-button device. Clinical and radiological evaluations were performed at preoperative, postoperative first day, 3 months and last follow-up. When the coracoclavicular (CC) distances of patients at the last follow-up were compared to the early postop CC distances, those with a difference of 3 mm or less were grouped as group A and those with a difference of more than 3 mm were grouped as group B. RESULTS: There was no statistically significant difference between the groups in terms of age, gender, follow-up time, time from injury to surgery, return to work, and distribution of Rockwood classification. Pre-operative CC distance was reduced from 18.7 ± 3.5 to 8.5 ± 0.6 in the early postoperative period. Anatomic reduction was achieved in all patients compared with the unaffected side (CC distance 8.6 ± 0.7). However, the CC distance increased to 9.9 ± 1.5 at the third-month follow-up and increased to 11 ± 2.7 at the last follow-up. There were no significant Constant score differences between the groups in the preoperative and last follow-up periods (p > 0.05). At the last follow-up, the mean Acromioclavicular Joint Instability (ACJI) score of group A was 84.4 ± 8, whereas it was 68.3 ± 8.3 for group B, and the difference was statistically significant (p < 0.01). Furthermore, the subjective evaluation and aesthetic subjective satisfaction values of group B were lower than group A (p < 0.01). CONCLUSIONS: Reduction loss of more than 3 mm was observed in 25% of patients after arthroscopic fixation of acute acromioclavicular dislocations using a double-button device. Although this loss did not create a statistically significant difference in Constant scores, AC joint-specific tests such as ACJI, subjective evaluation, and aesthetic subjective satisfaction values were significantly impaired.
format Online
Article
Text
id pubmed-7144043
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-71440432020-04-14 The frequency of reduction loss after arthroscopic fixation of acute acromioclavicular dislocations using a double-button device, and its effect on clinical and radiological results Çarkçı, Engin Polat, Ayşe Esin Gürpınar, Tahsin J Orthop Surg Res Research Article BACKGROUND: The aim of this study was to investigate the effect of reduction loss of more than 3 mm on clinical and radiological results after at least 2 years of follow-up after arthroscopic fixation of acute acromioclavicular joint dislocations using a double-button device. METHODS: Thirty-six patients who had acute (< 3 weeks old), type III or V acromioclavicular (AC) joint dislocations underwent arthroscopic fixation of the AC joint using a double-button device. Clinical and radiological evaluations were performed at preoperative, postoperative first day, 3 months and last follow-up. When the coracoclavicular (CC) distances of patients at the last follow-up were compared to the early postop CC distances, those with a difference of 3 mm or less were grouped as group A and those with a difference of more than 3 mm were grouped as group B. RESULTS: There was no statistically significant difference between the groups in terms of age, gender, follow-up time, time from injury to surgery, return to work, and distribution of Rockwood classification. Pre-operative CC distance was reduced from 18.7 ± 3.5 to 8.5 ± 0.6 in the early postoperative period. Anatomic reduction was achieved in all patients compared with the unaffected side (CC distance 8.6 ± 0.7). However, the CC distance increased to 9.9 ± 1.5 at the third-month follow-up and increased to 11 ± 2.7 at the last follow-up. There were no significant Constant score differences between the groups in the preoperative and last follow-up periods (p > 0.05). At the last follow-up, the mean Acromioclavicular Joint Instability (ACJI) score of group A was 84.4 ± 8, whereas it was 68.3 ± 8.3 for group B, and the difference was statistically significant (p < 0.01). Furthermore, the subjective evaluation and aesthetic subjective satisfaction values of group B were lower than group A (p < 0.01). CONCLUSIONS: Reduction loss of more than 3 mm was observed in 25% of patients after arthroscopic fixation of acute acromioclavicular dislocations using a double-button device. Although this loss did not create a statistically significant difference in Constant scores, AC joint-specific tests such as ACJI, subjective evaluation, and aesthetic subjective satisfaction values were significantly impaired. BioMed Central 2020-04-08 /pmc/articles/PMC7144043/ /pubmed/32268914 http://dx.doi.org/10.1186/s13018-020-01674-x Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Çarkçı, Engin
Polat, Ayşe Esin
Gürpınar, Tahsin
The frequency of reduction loss after arthroscopic fixation of acute acromioclavicular dislocations using a double-button device, and its effect on clinical and radiological results
title The frequency of reduction loss after arthroscopic fixation of acute acromioclavicular dislocations using a double-button device, and its effect on clinical and radiological results
title_full The frequency of reduction loss after arthroscopic fixation of acute acromioclavicular dislocations using a double-button device, and its effect on clinical and radiological results
title_fullStr The frequency of reduction loss after arthroscopic fixation of acute acromioclavicular dislocations using a double-button device, and its effect on clinical and radiological results
title_full_unstemmed The frequency of reduction loss after arthroscopic fixation of acute acromioclavicular dislocations using a double-button device, and its effect on clinical and radiological results
title_short The frequency of reduction loss after arthroscopic fixation of acute acromioclavicular dislocations using a double-button device, and its effect on clinical and radiological results
title_sort frequency of reduction loss after arthroscopic fixation of acute acromioclavicular dislocations using a double-button device, and its effect on clinical and radiological results
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7144043/
https://www.ncbi.nlm.nih.gov/pubmed/32268914
http://dx.doi.org/10.1186/s13018-020-01674-x
work_keys_str_mv AT carkcıengin thefrequencyofreductionlossafterarthroscopicfixationofacuteacromioclaviculardislocationsusingadoublebuttondeviceanditseffectonclinicalandradiologicalresults
AT polatayseesin thefrequencyofreductionlossafterarthroscopicfixationofacuteacromioclaviculardislocationsusingadoublebuttondeviceanditseffectonclinicalandradiologicalresults
AT gurpınartahsin thefrequencyofreductionlossafterarthroscopicfixationofacuteacromioclaviculardislocationsusingadoublebuttondeviceanditseffectonclinicalandradiologicalresults
AT carkcıengin frequencyofreductionlossafterarthroscopicfixationofacuteacromioclaviculardislocationsusingadoublebuttondeviceanditseffectonclinicalandradiologicalresults
AT polatayseesin frequencyofreductionlossafterarthroscopicfixationofacuteacromioclaviculardislocationsusingadoublebuttondeviceanditseffectonclinicalandradiologicalresults
AT gurpınartahsin frequencyofreductionlossafterarthroscopicfixationofacuteacromioclaviculardislocationsusingadoublebuttondeviceanditseffectonclinicalandradiologicalresults