Cargando…
Comparing the Effect of Bupivacaine and Ropivacaine in Cesarean Delivery with Spinal Anesthesia
BACKGROUND: Spinal anesthesia is the most common technique used for cesarean delivery due to some advantages compared to regional anesthesia. It is easily performed and provides a rapid onset of block. Though bupivacaine is a generally used long-acting amide type local anesthetic drug for spinal ane...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kowsar
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7144247/ https://www.ncbi.nlm.nih.gov/pubmed/32337166 http://dx.doi.org/10.5812/aapm.94155 |
_version_ | 1783519800895471616 |
---|---|
author | Olapour, Alireza Akhondzadeh, Reza Rashidi, Mahbobe Gousheh, Mohammadreza Homayoon, Raziyeh |
author_facet | Olapour, Alireza Akhondzadeh, Reza Rashidi, Mahbobe Gousheh, Mohammadreza Homayoon, Raziyeh |
author_sort | Olapour, Alireza |
collection | PubMed |
description | BACKGROUND: Spinal anesthesia is the most common technique used for cesarean delivery due to some advantages compared to regional anesthesia. It is easily performed and provides a rapid onset of block. Though bupivacaine is a generally used long-acting amide type local anesthetic drug for spinal anesthesia, ropivacaine may sometimes be selected. OBJECTIVES: This prospective, randomized, double-blinded study was aimed at comparing clinical efficacy and safety between ropivacaine and bupivacaine during cesarean section. METHODS: After getting ethical committee approval and written informed consent, 65 women who referred to Imam Khomeini Hospital of Ahvaz, Iran in 2018 were chosen for elective cesarean delivery under spinal anesthesia. They were randomly allocated to receive either ropivacaine 1% (n = 33) or bupivacaine 0.5% (n = 32). Afterwards, the differences in the anesthetic efficacy, vital signs, and hemodynamics of participants between the two groups were recorded. RESULTS: Duration of sensory block was shorter in the ropivacaine group than bupivacaine group (132.5 ± 21.6 min vs. 175.8 ± 26.2 min; P < 0.001). Ropivacaine also produced a shorter duration of motor blockade than bupivacaine (124.8 ± 20.2 min vs. 168.2 ± 21.7 min; P < 0.001). There is no difference between the two groups in terms of systolic and diastolic blood pressure, but the heart rate of patients in the bupivacaine group is significantly higher than the ropivacaine group. CONCLUSIONS: The results suggest that ropivacaine and bupivacaine are two efficient drugs in anesthesia in the cesarean section, ropivacaine is a better choice due to little influence on the hemodynamics and shorter duration of sensory block and motor block which are useful for the recovery and also safe to the patients. |
format | Online Article Text |
id | pubmed-7144247 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Kowsar |
record_format | MEDLINE/PubMed |
spelling | pubmed-71442472020-04-24 Comparing the Effect of Bupivacaine and Ropivacaine in Cesarean Delivery with Spinal Anesthesia Olapour, Alireza Akhondzadeh, Reza Rashidi, Mahbobe Gousheh, Mohammadreza Homayoon, Raziyeh Anesth Pain Med Research Article BACKGROUND: Spinal anesthesia is the most common technique used for cesarean delivery due to some advantages compared to regional anesthesia. It is easily performed and provides a rapid onset of block. Though bupivacaine is a generally used long-acting amide type local anesthetic drug for spinal anesthesia, ropivacaine may sometimes be selected. OBJECTIVES: This prospective, randomized, double-blinded study was aimed at comparing clinical efficacy and safety between ropivacaine and bupivacaine during cesarean section. METHODS: After getting ethical committee approval and written informed consent, 65 women who referred to Imam Khomeini Hospital of Ahvaz, Iran in 2018 were chosen for elective cesarean delivery under spinal anesthesia. They were randomly allocated to receive either ropivacaine 1% (n = 33) or bupivacaine 0.5% (n = 32). Afterwards, the differences in the anesthetic efficacy, vital signs, and hemodynamics of participants between the two groups were recorded. RESULTS: Duration of sensory block was shorter in the ropivacaine group than bupivacaine group (132.5 ± 21.6 min vs. 175.8 ± 26.2 min; P < 0.001). Ropivacaine also produced a shorter duration of motor blockade than bupivacaine (124.8 ± 20.2 min vs. 168.2 ± 21.7 min; P < 0.001). There is no difference between the two groups in terms of systolic and diastolic blood pressure, but the heart rate of patients in the bupivacaine group is significantly higher than the ropivacaine group. CONCLUSIONS: The results suggest that ropivacaine and bupivacaine are two efficient drugs in anesthesia in the cesarean section, ropivacaine is a better choice due to little influence on the hemodynamics and shorter duration of sensory block and motor block which are useful for the recovery and also safe to the patients. Kowsar 2020-01-18 /pmc/articles/PMC7144247/ /pubmed/32337166 http://dx.doi.org/10.5812/aapm.94155 Text en Copyright © 2020, Author(s) http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited. |
spellingShingle | Research Article Olapour, Alireza Akhondzadeh, Reza Rashidi, Mahbobe Gousheh, Mohammadreza Homayoon, Raziyeh Comparing the Effect of Bupivacaine and Ropivacaine in Cesarean Delivery with Spinal Anesthesia |
title | Comparing the Effect of Bupivacaine and Ropivacaine in Cesarean Delivery with Spinal Anesthesia |
title_full | Comparing the Effect of Bupivacaine and Ropivacaine in Cesarean Delivery with Spinal Anesthesia |
title_fullStr | Comparing the Effect of Bupivacaine and Ropivacaine in Cesarean Delivery with Spinal Anesthesia |
title_full_unstemmed | Comparing the Effect of Bupivacaine and Ropivacaine in Cesarean Delivery with Spinal Anesthesia |
title_short | Comparing the Effect of Bupivacaine and Ropivacaine in Cesarean Delivery with Spinal Anesthesia |
title_sort | comparing the effect of bupivacaine and ropivacaine in cesarean delivery with spinal anesthesia |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7144247/ https://www.ncbi.nlm.nih.gov/pubmed/32337166 http://dx.doi.org/10.5812/aapm.94155 |
work_keys_str_mv | AT olapouralireza comparingtheeffectofbupivacaineandropivacaineincesareandeliverywithspinalanesthesia AT akhondzadehreza comparingtheeffectofbupivacaineandropivacaineincesareandeliverywithspinalanesthesia AT rashidimahbobe comparingtheeffectofbupivacaineandropivacaineincesareandeliverywithspinalanesthesia AT goushehmohammadreza comparingtheeffectofbupivacaineandropivacaineincesareandeliverywithspinalanesthesia AT homayoonraziyeh comparingtheeffectofbupivacaineandropivacaineincesareandeliverywithspinalanesthesia |