Comparison of the Depth of Cure of Flowable Composites Polymerized at Variable Increment Thicknesses and Voltages: An In vitro Study

OBJECTIVES: The aim of this study is to compare the depth of cure of two composite materials (SDR and Filtek bulk-fill) cured at variable increment depths (2, 4, and 6 mm) and voltages (180 and 220 volts). MATERIALS AND METHODS: Each sample of the composite material was packed in a mold of 2 mm, 4 m...

Descripción completa

Detalles Bibliográficos
Autores principales: Tabassum, Sadia, Hameed, Muhammad Hasan, Khan, Farhan Raza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7145244/
https://www.ncbi.nlm.nih.gov/pubmed/32308281
http://dx.doi.org/10.4103/ccd.ccd_635_18
_version_ 1783519963894513664
author Tabassum, Sadia
Hameed, Muhammad Hasan
Khan, Farhan Raza
author_facet Tabassum, Sadia
Hameed, Muhammad Hasan
Khan, Farhan Raza
author_sort Tabassum, Sadia
collection PubMed
description OBJECTIVES: The aim of this study is to compare the depth of cure of two composite materials (SDR and Filtek bulk-fill) cured at variable increment depths (2, 4, and 6 mm) and voltages (180 and 220 volts). MATERIALS AND METHODS: Each sample of the composite material was packed in a mold of 2 mm, 4 mm, and 6 mm and curing light (quartz tungsten halogen) of optimal intensity was exposed for 20 s at 2 different voltages on each specimen. After curing, the specimens were removed and the composite on the nonexposed end was scraped with a plastic instrument. The remaining composite thickness was measured using a digital Vernier caliper. The reading was divided by half to follow the ISO 4049 method. Independent sample t-test, one-way ANOVA, and linear regression analysis were applied. Level of significance was kept at 0.01. RESULTS: The mean DOC of SDR and Filtek were 1.93 ± 0.82 and 1.77 ± 0.65 mm. Lowering the voltage from 220 to 180 volts reduced the depth of Filtek from 1.87 ± 0.74 to 1.67 ± 0.54 mm, whereas the DOC of SDR remained unchanged at 1.93 mm at the two voltages. The adjusted R(2) for the depth of cure was 0.93 when the increment thickness, voltage, and restorative material were taken together in the regression model. CONCLUSIONS: There was no statistically significant difference between SDR and Filtek for the depth of cure at 2 and 4 mm increments. However, at 6 mm increment, the SDR cured significantly deeper than the Filtek. Around 91% variation in the depth of cure of these composites materials is explained by increment thickness alone.
format Online
Article
Text
id pubmed-7145244
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-71452442020-04-17 Comparison of the Depth of Cure of Flowable Composites Polymerized at Variable Increment Thicknesses and Voltages: An In vitro Study Tabassum, Sadia Hameed, Muhammad Hasan Khan, Farhan Raza Contemp Clin Dent Original Article OBJECTIVES: The aim of this study is to compare the depth of cure of two composite materials (SDR and Filtek bulk-fill) cured at variable increment depths (2, 4, and 6 mm) and voltages (180 and 220 volts). MATERIALS AND METHODS: Each sample of the composite material was packed in a mold of 2 mm, 4 mm, and 6 mm and curing light (quartz tungsten halogen) of optimal intensity was exposed for 20 s at 2 different voltages on each specimen. After curing, the specimens were removed and the composite on the nonexposed end was scraped with a plastic instrument. The remaining composite thickness was measured using a digital Vernier caliper. The reading was divided by half to follow the ISO 4049 method. Independent sample t-test, one-way ANOVA, and linear regression analysis were applied. Level of significance was kept at 0.01. RESULTS: The mean DOC of SDR and Filtek were 1.93 ± 0.82 and 1.77 ± 0.65 mm. Lowering the voltage from 220 to 180 volts reduced the depth of Filtek from 1.87 ± 0.74 to 1.67 ± 0.54 mm, whereas the DOC of SDR remained unchanged at 1.93 mm at the two voltages. The adjusted R(2) for the depth of cure was 0.93 when the increment thickness, voltage, and restorative material were taken together in the regression model. CONCLUSIONS: There was no statistically significant difference between SDR and Filtek for the depth of cure at 2 and 4 mm increments. However, at 6 mm increment, the SDR cured significantly deeper than the Filtek. Around 91% variation in the depth of cure of these composites materials is explained by increment thickness alone. Wolters Kluwer - Medknow 2019 /pmc/articles/PMC7145244/ /pubmed/32308281 http://dx.doi.org/10.4103/ccd.ccd_635_18 Text en Copyright: © 2020 Contemporary Clinical Dentistry http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Tabassum, Sadia
Hameed, Muhammad Hasan
Khan, Farhan Raza
Comparison of the Depth of Cure of Flowable Composites Polymerized at Variable Increment Thicknesses and Voltages: An In vitro Study
title Comparison of the Depth of Cure of Flowable Composites Polymerized at Variable Increment Thicknesses and Voltages: An In vitro Study
title_full Comparison of the Depth of Cure of Flowable Composites Polymerized at Variable Increment Thicknesses and Voltages: An In vitro Study
title_fullStr Comparison of the Depth of Cure of Flowable Composites Polymerized at Variable Increment Thicknesses and Voltages: An In vitro Study
title_full_unstemmed Comparison of the Depth of Cure of Flowable Composites Polymerized at Variable Increment Thicknesses and Voltages: An In vitro Study
title_short Comparison of the Depth of Cure of Flowable Composites Polymerized at Variable Increment Thicknesses and Voltages: An In vitro Study
title_sort comparison of the depth of cure of flowable composites polymerized at variable increment thicknesses and voltages: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7145244/
https://www.ncbi.nlm.nih.gov/pubmed/32308281
http://dx.doi.org/10.4103/ccd.ccd_635_18
work_keys_str_mv AT tabassumsadia comparisonofthedepthofcureofflowablecompositespolymerizedatvariableincrementthicknessesandvoltagesaninvitrostudy
AT hameedmuhammadhasan comparisonofthedepthofcureofflowablecompositespolymerizedatvariableincrementthicknessesandvoltagesaninvitrostudy
AT khanfarhanraza comparisonofthedepthofcureofflowablecompositespolymerizedatvariableincrementthicknessesandvoltagesaninvitrostudy