Comparison of the Depth of Cure of Flowable Composites Polymerized at Variable Increment Thicknesses and Voltages: An In vitro Study
OBJECTIVES: The aim of this study is to compare the depth of cure of two composite materials (SDR and Filtek bulk-fill) cured at variable increment depths (2, 4, and 6 mm) and voltages (180 and 220 volts). MATERIALS AND METHODS: Each sample of the composite material was packed in a mold of 2 mm, 4 m...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7145244/ https://www.ncbi.nlm.nih.gov/pubmed/32308281 http://dx.doi.org/10.4103/ccd.ccd_635_18 |
_version_ | 1783519963894513664 |
---|---|
author | Tabassum, Sadia Hameed, Muhammad Hasan Khan, Farhan Raza |
author_facet | Tabassum, Sadia Hameed, Muhammad Hasan Khan, Farhan Raza |
author_sort | Tabassum, Sadia |
collection | PubMed |
description | OBJECTIVES: The aim of this study is to compare the depth of cure of two composite materials (SDR and Filtek bulk-fill) cured at variable increment depths (2, 4, and 6 mm) and voltages (180 and 220 volts). MATERIALS AND METHODS: Each sample of the composite material was packed in a mold of 2 mm, 4 mm, and 6 mm and curing light (quartz tungsten halogen) of optimal intensity was exposed for 20 s at 2 different voltages on each specimen. After curing, the specimens were removed and the composite on the nonexposed end was scraped with a plastic instrument. The remaining composite thickness was measured using a digital Vernier caliper. The reading was divided by half to follow the ISO 4049 method. Independent sample t-test, one-way ANOVA, and linear regression analysis were applied. Level of significance was kept at 0.01. RESULTS: The mean DOC of SDR and Filtek were 1.93 ± 0.82 and 1.77 ± 0.65 mm. Lowering the voltage from 220 to 180 volts reduced the depth of Filtek from 1.87 ± 0.74 to 1.67 ± 0.54 mm, whereas the DOC of SDR remained unchanged at 1.93 mm at the two voltages. The adjusted R(2) for the depth of cure was 0.93 when the increment thickness, voltage, and restorative material were taken together in the regression model. CONCLUSIONS: There was no statistically significant difference between SDR and Filtek for the depth of cure at 2 and 4 mm increments. However, at 6 mm increment, the SDR cured significantly deeper than the Filtek. Around 91% variation in the depth of cure of these composites materials is explained by increment thickness alone. |
format | Online Article Text |
id | pubmed-7145244 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-71452442020-04-17 Comparison of the Depth of Cure of Flowable Composites Polymerized at Variable Increment Thicknesses and Voltages: An In vitro Study Tabassum, Sadia Hameed, Muhammad Hasan Khan, Farhan Raza Contemp Clin Dent Original Article OBJECTIVES: The aim of this study is to compare the depth of cure of two composite materials (SDR and Filtek bulk-fill) cured at variable increment depths (2, 4, and 6 mm) and voltages (180 and 220 volts). MATERIALS AND METHODS: Each sample of the composite material was packed in a mold of 2 mm, 4 mm, and 6 mm and curing light (quartz tungsten halogen) of optimal intensity was exposed for 20 s at 2 different voltages on each specimen. After curing, the specimens were removed and the composite on the nonexposed end was scraped with a plastic instrument. The remaining composite thickness was measured using a digital Vernier caliper. The reading was divided by half to follow the ISO 4049 method. Independent sample t-test, one-way ANOVA, and linear regression analysis were applied. Level of significance was kept at 0.01. RESULTS: The mean DOC of SDR and Filtek were 1.93 ± 0.82 and 1.77 ± 0.65 mm. Lowering the voltage from 220 to 180 volts reduced the depth of Filtek from 1.87 ± 0.74 to 1.67 ± 0.54 mm, whereas the DOC of SDR remained unchanged at 1.93 mm at the two voltages. The adjusted R(2) for the depth of cure was 0.93 when the increment thickness, voltage, and restorative material were taken together in the regression model. CONCLUSIONS: There was no statistically significant difference between SDR and Filtek for the depth of cure at 2 and 4 mm increments. However, at 6 mm increment, the SDR cured significantly deeper than the Filtek. Around 91% variation in the depth of cure of these composites materials is explained by increment thickness alone. Wolters Kluwer - Medknow 2019 /pmc/articles/PMC7145244/ /pubmed/32308281 http://dx.doi.org/10.4103/ccd.ccd_635_18 Text en Copyright: © 2020 Contemporary Clinical Dentistry http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Tabassum, Sadia Hameed, Muhammad Hasan Khan, Farhan Raza Comparison of the Depth of Cure of Flowable Composites Polymerized at Variable Increment Thicknesses and Voltages: An In vitro Study |
title | Comparison of the Depth of Cure of Flowable Composites Polymerized at Variable Increment Thicknesses and Voltages: An In vitro Study |
title_full | Comparison of the Depth of Cure of Flowable Composites Polymerized at Variable Increment Thicknesses and Voltages: An In vitro Study |
title_fullStr | Comparison of the Depth of Cure of Flowable Composites Polymerized at Variable Increment Thicknesses and Voltages: An In vitro Study |
title_full_unstemmed | Comparison of the Depth of Cure of Flowable Composites Polymerized at Variable Increment Thicknesses and Voltages: An In vitro Study |
title_short | Comparison of the Depth of Cure of Flowable Composites Polymerized at Variable Increment Thicknesses and Voltages: An In vitro Study |
title_sort | comparison of the depth of cure of flowable composites polymerized at variable increment thicknesses and voltages: an in vitro study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7145244/ https://www.ncbi.nlm.nih.gov/pubmed/32308281 http://dx.doi.org/10.4103/ccd.ccd_635_18 |
work_keys_str_mv | AT tabassumsadia comparisonofthedepthofcureofflowablecompositespolymerizedatvariableincrementthicknessesandvoltagesaninvitrostudy AT hameedmuhammadhasan comparisonofthedepthofcureofflowablecompositespolymerizedatvariableincrementthicknessesandvoltagesaninvitrostudy AT khanfarhanraza comparisonofthedepthofcureofflowablecompositespolymerizedatvariableincrementthicknessesandvoltagesaninvitrostudy |