Cargando…

Comparison of Using Cold Versus Regular Temperature Tube on Successful Nasogastric Intubation for Patients in Toxicology Emergency Department: a Randomized Clinical Trial

Introduction: In view of the contradictory results for the use of cold tubes for the purpose of enhancing nasogastric tube insertion success there is a pressing need for further research in this area. This study aimed to determine the effect of using cold versus regular temperature nasogastric tube...

Descripción completa

Detalles Bibliográficos
Autores principales: Mazlom, Seyed Reza, Firouzian, Ali Asghar, Norozi, Heji Mohamad, Ghasemi Toussi, Alireza, Marhamati, Mahmoud
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tabriz University of Medical Sciences 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7146729/
https://www.ncbi.nlm.nih.gov/pubmed/32296655
http://dx.doi.org/10.34172/jcs.2020.004
_version_ 1783520268635865088
author Mazlom, Seyed Reza
Firouzian, Ali Asghar
Norozi, Heji Mohamad
Ghasemi Toussi, Alireza
Marhamati, Mahmoud
author_facet Mazlom, Seyed Reza
Firouzian, Ali Asghar
Norozi, Heji Mohamad
Ghasemi Toussi, Alireza
Marhamati, Mahmoud
author_sort Mazlom, Seyed Reza
collection PubMed
description Introduction: In view of the contradictory results for the use of cold tubes for the purpose of enhancing nasogastric tube insertion success there is a pressing need for further research in this area. This study aimed to determine the effect of using cold versus regular temperature nasogastric tube on successful nasogastric tube insertion for patients referring to toxicology emergency department. Methods: This study is a clinical trial with two groups design of 65 patients admitted to toxicology emergency department who were divided into two groups by random allocation. Nasogastric tubes used in the intervention group had been stored in a refrigerator at 2°-8° C while the ones employed in the control group had been maintained at the room temperature of 22-28° C. Nasogastric tube insertions in both groups were done by the investigator according to standard methods. The data were analyzed using SPSS ver. 13. Results: The placement of nasogastric tube was done in the first attempt with 27 (%84.4) of the subjects in the control group and 33 (%100.0) in the intervention group. The chi-square test results showed that the frequency of the number of attempts for gastric intubation in subjects between the two groups was statistically significant. Conclusion: Cooling gastric tubes reduces the time required for nasogastric intubation. Thus, it is suggested that the gastric tubes be cooled before the application of the procedure so as to reduce complications, increase patient comfort and save nurses time.
format Online
Article
Text
id pubmed-7146729
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Tabriz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-71467292020-04-15 Comparison of Using Cold Versus Regular Temperature Tube on Successful Nasogastric Intubation for Patients in Toxicology Emergency Department: a Randomized Clinical Trial Mazlom, Seyed Reza Firouzian, Ali Asghar Norozi, Heji Mohamad Ghasemi Toussi, Alireza Marhamati, Mahmoud J Caring Sci Original Article Introduction: In view of the contradictory results for the use of cold tubes for the purpose of enhancing nasogastric tube insertion success there is a pressing need for further research in this area. This study aimed to determine the effect of using cold versus regular temperature nasogastric tube on successful nasogastric tube insertion for patients referring to toxicology emergency department. Methods: This study is a clinical trial with two groups design of 65 patients admitted to toxicology emergency department who were divided into two groups by random allocation. Nasogastric tubes used in the intervention group had been stored in a refrigerator at 2°-8° C while the ones employed in the control group had been maintained at the room temperature of 22-28° C. Nasogastric tube insertions in both groups were done by the investigator according to standard methods. The data were analyzed using SPSS ver. 13. Results: The placement of nasogastric tube was done in the first attempt with 27 (%84.4) of the subjects in the control group and 33 (%100.0) in the intervention group. The chi-square test results showed that the frequency of the number of attempts for gastric intubation in subjects between the two groups was statistically significant. Conclusion: Cooling gastric tubes reduces the time required for nasogastric intubation. Thus, it is suggested that the gastric tubes be cooled before the application of the procedure so as to reduce complications, increase patient comfort and save nurses time. Tabriz University of Medical Sciences 2020-03-01 /pmc/articles/PMC7146729/ /pubmed/32296655 http://dx.doi.org/10.34172/jcs.2020.004 Text en © 2020 The Author(s). http://creativecommons.org/licenses/by-nc/4.0/ This work is published by Journal of Caring Sciences as an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by-nc/4.0/). Non-commercial uses of the work are permitted, provided the original work is properly cited.
spellingShingle Original Article
Mazlom, Seyed Reza
Firouzian, Ali Asghar
Norozi, Heji Mohamad
Ghasemi Toussi, Alireza
Marhamati, Mahmoud
Comparison of Using Cold Versus Regular Temperature Tube on Successful Nasogastric Intubation for Patients in Toxicology Emergency Department: a Randomized Clinical Trial
title Comparison of Using Cold Versus Regular Temperature Tube on Successful Nasogastric Intubation for Patients in Toxicology Emergency Department: a Randomized Clinical Trial
title_full Comparison of Using Cold Versus Regular Temperature Tube on Successful Nasogastric Intubation for Patients in Toxicology Emergency Department: a Randomized Clinical Trial
title_fullStr Comparison of Using Cold Versus Regular Temperature Tube on Successful Nasogastric Intubation for Patients in Toxicology Emergency Department: a Randomized Clinical Trial
title_full_unstemmed Comparison of Using Cold Versus Regular Temperature Tube on Successful Nasogastric Intubation for Patients in Toxicology Emergency Department: a Randomized Clinical Trial
title_short Comparison of Using Cold Versus Regular Temperature Tube on Successful Nasogastric Intubation for Patients in Toxicology Emergency Department: a Randomized Clinical Trial
title_sort comparison of using cold versus regular temperature tube on successful nasogastric intubation for patients in toxicology emergency department: a randomized clinical trial
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7146729/
https://www.ncbi.nlm.nih.gov/pubmed/32296655
http://dx.doi.org/10.34172/jcs.2020.004
work_keys_str_mv AT mazlomseyedreza comparisonofusingcoldversusregulartemperaturetubeonsuccessfulnasogastricintubationforpatientsintoxicologyemergencydepartmentarandomizedclinicaltrial
AT firouzianaliasghar comparisonofusingcoldversusregulartemperaturetubeonsuccessfulnasogastricintubationforpatientsintoxicologyemergencydepartmentarandomizedclinicaltrial
AT norozihejimohamad comparisonofusingcoldversusregulartemperaturetubeonsuccessfulnasogastricintubationforpatientsintoxicologyemergencydepartmentarandomizedclinicaltrial
AT ghasemitoussialireza comparisonofusingcoldversusregulartemperaturetubeonsuccessfulnasogastricintubationforpatientsintoxicologyemergencydepartmentarandomizedclinicaltrial
AT marhamatimahmoud comparisonofusingcoldversusregulartemperaturetubeonsuccessfulnasogastricintubationforpatientsintoxicologyemergencydepartmentarandomizedclinicaltrial