Cargando…

Disinfection efficiency of positive pressure respiratory protective hood using fumigation sterilization cabinet

Concerns have been raised about both the disinfection and the reusability of respiratory protective equipment following a disinfection process. Currently, there is little data available on the effects of disinfection and decontamination on positive pressure respiratory protective hoods (PPRPH). In t...

Descripción completa

Detalles Bibliográficos
Autores principales: Hao, Limei, Wu, Jinhui, Zhang, Enlei, Yi, Ying, Zhang, Zongxing, Zhang, Jinming, Qi, Jiancheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Chinese Medical Association Publishing House. Published by Elsevier B.V. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7148600/
https://www.ncbi.nlm.nih.gov/pubmed/32501442
http://dx.doi.org/10.1016/j.bsheal.2019.02.006
Descripción
Sumario:Concerns have been raised about both the disinfection and the reusability of respiratory protective equipment following a disinfection process. Currently, there is little data available on the effects of disinfection and decontamination on positive pressure respiratory protective hoods (PPRPH). In this study, we evaluated the effect of vaporized hydrogen peroxide (VHP) on the disinfection of PPRPH to determine applicability of this method for disinfection of protective equipment, especially protective equipment with an electric supply system. A hydrogen peroxide-based fumigation sterilization cabinet was developed particularly for disinfection of protective equipment, and the disinfection experiments were conducted using four PPRPHs hung in the fumigation chamber. The pathogenic microorganism Geobacillus stearothermophilus ATCC 7953 was used as a biological indicator in this study and the relationship between air flow (the amount of VHP) and disinfection was investigated. Both function and the material physical properties of the PPRPH were assessed following the disinfection procedure. No surviving Geobacillus stearothermophilus ATCC 7953, both inside and outside of these disinfected PPRPHs, could be observed after a 60 min treatment with an air flow of 10.5–12.3 m(3)/h. Both function and material physical properties of these PPRPHs met the working requirements after disinfection. This study indicates that air flow in the fumigation chamber directly influences the concentration of VHP. The protective equipment fumigation sterilization cabinet developed in this paper achieves the complete sterilization of the PPRPHs when the air flow is at 10.5–12.3 m(3)/h, and provides a potential solution for the disinfection of various kind of protective equipment.