Cargando…
Chromatography of complex protein mixtures
This review has shown that a variety of chromatographic techniques are available for fractionating proteins. Fortunately, high-quality columns of every type described in this review are commercially available. Most water-soluble proteins may be eluted from size-exclusion, hydrophobic-interaction, io...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Published by Elsevier B.V.
1987
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7148779/ https://www.ncbi.nlm.nih.gov/pubmed/3305538 http://dx.doi.org/10.1016/0378-4347(87)80007-5 |
_version_ | 1783520667061190656 |
---|---|
author | Regnier, Fred E. |
author_facet | Regnier, Fred E. |
author_sort | Regnier, Fred E. |
collection | PubMed |
description | This review has shown that a variety of chromatographic techniques are available for fractionating proteins. Fortunately, high-quality columns of every type described in this review are commercially available. Most water-soluble proteins may be eluted from size-exclusion, hydrophobic-interaction, ion-exchange, metal chelate, and bioaffinity columns with ease. When this is the case, high recovery and retention of biological activity are the norm. The exception is reversed-phase chromatography where the organic solvents and acids used in polypeptide elution denature many proteins. When problems do occur, they are generally the result of unique structural features of the protein. Very hydrophobic proteins have presented the biggest problem in that they are difficult to solubilize, particularly with retention of biological activity. It has been found that zwitterionic an non-ionic detergents are the most suitable solubilizing agents, but area has also been used in cases where hydrophobic interacts are not as strong. Unfortunately, there is still an element of trial-and-error in selecting the most suitable solubilizing agent. Heterogeneous glycosylation of proteins also presents a problem. Both neutral and charged monosaccharides can be incorporated into proteins through multiple steps at several sites. Thus, there is the potential in a sample for a large number of glycoprotein species which have the same polypeptide backbone and differing amounts of oligosaccharide. A problem arises when size-exclusion, ion-exchange, hydrophobic-interaction, reversed-phase and bioaffinity systems begin to discriminate between these very similar glycoprotein species. Chromatographic peaks can become very load, due to incomplete fractionation, and the polypeptide chain of interest can be associated with multiple peaks. The separation of glycoproteins requires much more study before logical procedures can be suggested for column selection and operation. Aggregated species are another class of proteins which present occasional problems. Multimeric proteins are adsorbed to sorbents by a series of forces, among which are hydrogen bonding, hydrophobic interactions, and electrostatic forces. These forces are also responsible for the maintenance of quaternary structure in proteins. When the same forces dominate both retention of protein structure and adsorption at the sorbent surface, the quaternary structure of the protein can be disrupted during elution. Very basic proteins also present a problem in some cases. Columns with residual negative charges, such as a silica-based reversed-phase column, adsorb anionic species so strongly that they are difficult to elute. This is the case with ribosomal and nucleoproteins. The solution is to use exhaustively end-capped columns which diminish electrostatic interactions. |
format | Online Article Text |
id | pubmed-7148779 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1987 |
publisher | Published by Elsevier B.V. |
record_format | MEDLINE/PubMed |
spelling | pubmed-71487792020-04-13 Chromatography of complex protein mixtures Regnier, Fred E. Journal of Chromatography B: Biomedical Sciences and Applications Article This review has shown that a variety of chromatographic techniques are available for fractionating proteins. Fortunately, high-quality columns of every type described in this review are commercially available. Most water-soluble proteins may be eluted from size-exclusion, hydrophobic-interaction, ion-exchange, metal chelate, and bioaffinity columns with ease. When this is the case, high recovery and retention of biological activity are the norm. The exception is reversed-phase chromatography where the organic solvents and acids used in polypeptide elution denature many proteins. When problems do occur, they are generally the result of unique structural features of the protein. Very hydrophobic proteins have presented the biggest problem in that they are difficult to solubilize, particularly with retention of biological activity. It has been found that zwitterionic an non-ionic detergents are the most suitable solubilizing agents, but area has also been used in cases where hydrophobic interacts are not as strong. Unfortunately, there is still an element of trial-and-error in selecting the most suitable solubilizing agent. Heterogeneous glycosylation of proteins also presents a problem. Both neutral and charged monosaccharides can be incorporated into proteins through multiple steps at several sites. Thus, there is the potential in a sample for a large number of glycoprotein species which have the same polypeptide backbone and differing amounts of oligosaccharide. A problem arises when size-exclusion, ion-exchange, hydrophobic-interaction, reversed-phase and bioaffinity systems begin to discriminate between these very similar glycoprotein species. Chromatographic peaks can become very load, due to incomplete fractionation, and the polypeptide chain of interest can be associated with multiple peaks. The separation of glycoproteins requires much more study before logical procedures can be suggested for column selection and operation. Aggregated species are another class of proteins which present occasional problems. Multimeric proteins are adsorbed to sorbents by a series of forces, among which are hydrogen bonding, hydrophobic interactions, and electrostatic forces. These forces are also responsible for the maintenance of quaternary structure in proteins. When the same forces dominate both retention of protein structure and adsorption at the sorbent surface, the quaternary structure of the protein can be disrupted during elution. Very basic proteins also present a problem in some cases. Columns with residual negative charges, such as a silica-based reversed-phase column, adsorb anionic species so strongly that they are difficult to elute. This is the case with ribosomal and nucleoproteins. The solution is to use exhaustively end-capped columns which diminish electrostatic interactions. Published by Elsevier B.V. 1987-07-17 2002-03-29 /pmc/articles/PMC7148779/ /pubmed/3305538 http://dx.doi.org/10.1016/0378-4347(87)80007-5 Text en Copyright © 1987 Published by Elsevier B.V. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Regnier, Fred E. Chromatography of complex protein mixtures |
title | Chromatography of complex protein mixtures |
title_full | Chromatography of complex protein mixtures |
title_fullStr | Chromatography of complex protein mixtures |
title_full_unstemmed | Chromatography of complex protein mixtures |
title_short | Chromatography of complex protein mixtures |
title_sort | chromatography of complex protein mixtures |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7148779/ https://www.ncbi.nlm.nih.gov/pubmed/3305538 http://dx.doi.org/10.1016/0378-4347(87)80007-5 |
work_keys_str_mv | AT regnierfrede chromatographyofcomplexproteinmixtures |