BACKGROUND: Organic tin compounds (OTCs), a group of high-risk hazardous substances, are highly concerned in safety regulation of consumer products especially for toys because they can cause serious damage to organs after prolonged or repeated exposure. Gastric juice migration is nowadays widely imp...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Lina, Li, Hanke, Li, Yuhang, Ren, Peng, Yi, Lezhou, Chen, Yang, Ma, Tongmei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7150698/
https://www.ncbi.nlm.nih.gov/pubmed/32292479
http://dx.doi.org/10.1155/2020/1975471
_version_ 1783521077041823744
author Huang, Lina
Li, Hanke
Li, Yuhang
Ren, Peng
Yi, Lezhou
Chen, Yang
Ma, Tongmei
author_facet Huang, Lina
Li, Hanke
Li, Yuhang
Ren, Peng
Yi, Lezhou
Chen, Yang
Ma, Tongmei
author_sort Huang, Lina
collection PubMed
description BACKGROUND: Organic tin compounds (OTCs), a group of high-risk hazardous substances, are highly concerned in safety regulation of consumer products especially for toys because they can cause serious damage to organs after prolonged or repeated exposure. Gastric juice migration is nowadays widely implemented to assess organic tin intake from toys or food-contact materials; however, the followed up detection method using sodium tetraethylborate [NaB(Et(4))] as a derivatization agent may directly lead to false positive of monomethyltins (MMT). OBJECTIVE: In order to avoid the phenomena of false positive of MMT in the course of laboratory testing of toys, it is necessary and important to perform relative experimental and theoretical studies to reveal the cause of false positive of MMT. METHOD: With metal tin powder as a representative of inorganic tin which existed in real samples, it was treated with artificial gastric juice (0.07 mol/L·HCl), followed by ethyl derivatization using sodium tetraethylborate [NaB(Et)(4)] and then analyzed by gas chromatography-mass spectrometry (GC-MS) according to the procedure specified in the standard of EN 71-3:2013+A3:2018 issued by the European Committee for Standardization (CEN). RESULTS: Without any OTCs in the starting materials, MMT false positive can be reproduced by detecting 0.56 mg/L of triethylmethyltin (TEMT) together with approximately 1000 mg/L of tetraethyltin (TeET), which is similar to real samples. Further, it is demonstrated that the detected amount of TEMT is linearly related with the added amount of NaB(Et)(4), and that the formation of TEMT (methyl derivative) is easier than TeET (ethyl derivative) even though the ethyl group is present in a larger amount than the methyl group. CONCLUSIONS: The phenomena of MMT false positive which occurred in the laboratory testing of toys is mainly because that TEMT is highly likely to be obtained from the reaction of inorganic tin and trace level of methylation agent impurities contained in the derivatization reagent—NaB(Et)(4). To avoid MMT false positive, it is concluded that the maximum acceptable mole ratio of methylation agent impurities contained in NaB(Et)(4) is approximately 0.028%. This research is helpful to be aware of methylation impurities and is favorable to avoid false judgment caused by MMT false positive in routine analysis of toys.
format Online
Article
Text
id pubmed-7150698
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-71506982020-04-14 Experimental and Theoretical Study on the False Positive of Monomethyltin Determination in Toys Based on Gastric Juice Migration Huang, Lina Li, Hanke Li, Yuhang Ren, Peng Yi, Lezhou Chen, Yang Ma, Tongmei Int J Anal Chem Research Article BACKGROUND: Organic tin compounds (OTCs), a group of high-risk hazardous substances, are highly concerned in safety regulation of consumer products especially for toys because they can cause serious damage to organs after prolonged or repeated exposure. Gastric juice migration is nowadays widely implemented to assess organic tin intake from toys or food-contact materials; however, the followed up detection method using sodium tetraethylborate [NaB(Et(4))] as a derivatization agent may directly lead to false positive of monomethyltins (MMT). OBJECTIVE: In order to avoid the phenomena of false positive of MMT in the course of laboratory testing of toys, it is necessary and important to perform relative experimental and theoretical studies to reveal the cause of false positive of MMT. METHOD: With metal tin powder as a representative of inorganic tin which existed in real samples, it was treated with artificial gastric juice (0.07 mol/L·HCl), followed by ethyl derivatization using sodium tetraethylborate [NaB(Et)(4)] and then analyzed by gas chromatography-mass spectrometry (GC-MS) according to the procedure specified in the standard of EN 71-3:2013+A3:2018 issued by the European Committee for Standardization (CEN). RESULTS: Without any OTCs in the starting materials, MMT false positive can be reproduced by detecting 0.56 mg/L of triethylmethyltin (TEMT) together with approximately 1000 mg/L of tetraethyltin (TeET), which is similar to real samples. Further, it is demonstrated that the detected amount of TEMT is linearly related with the added amount of NaB(Et)(4), and that the formation of TEMT (methyl derivative) is easier than TeET (ethyl derivative) even though the ethyl group is present in a larger amount than the methyl group. CONCLUSIONS: The phenomena of MMT false positive which occurred in the laboratory testing of toys is mainly because that TEMT is highly likely to be obtained from the reaction of inorganic tin and trace level of methylation agent impurities contained in the derivatization reagent—NaB(Et)(4). To avoid MMT false positive, it is concluded that the maximum acceptable mole ratio of methylation agent impurities contained in NaB(Et)(4) is approximately 0.028%. This research is helpful to be aware of methylation impurities and is favorable to avoid false judgment caused by MMT false positive in routine analysis of toys. Hindawi 2020-03-31 /pmc/articles/PMC7150698/ /pubmed/32292479 http://dx.doi.org/10.1155/2020/1975471 Text en Copyright © 2020 Lina Huang et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Huang, Lina
Li, Hanke
Li, Yuhang
Ren, Peng
Yi, Lezhou
Chen, Yang
Ma, Tongmei
Experimental and Theoretical Study on the False Positive of Monomethyltin Determination in Toys Based on Gastric Juice Migration
title Experimental and Theoretical Study on the False Positive of Monomethyltin Determination in Toys Based on Gastric Juice Migration
title_full Experimental and Theoretical Study on the False Positive of Monomethyltin Determination in Toys Based on Gastric Juice Migration
title_fullStr Experimental and Theoretical Study on the False Positive of Monomethyltin Determination in Toys Based on Gastric Juice Migration
title_full_unstemmed Experimental and Theoretical Study on the False Positive of Monomethyltin Determination in Toys Based on Gastric Juice Migration
title_short Experimental and Theoretical Study on the False Positive of Monomethyltin Determination in Toys Based on Gastric Juice Migration
title_sort experimental and theoretical study on the false positive of monomethyltin determination in toys based on gastric juice migration
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7150698/
https://www.ncbi.nlm.nih.gov/pubmed/32292479
http://dx.doi.org/10.1155/2020/1975471
work_keys_str_mv AT huanglina experimentalandtheoreticalstudyonthefalsepositiveofmonomethyltindeterminationintoysbasedongastricjuicemigration
AT lihanke experimentalandtheoreticalstudyonthefalsepositiveofmonomethyltindeterminationintoysbasedongastricjuicemigration
AT liyuhang experimentalandtheoreticalstudyonthefalsepositiveofmonomethyltindeterminationintoysbasedongastricjuicemigration
AT renpeng experimentalandtheoreticalstudyonthefalsepositiveofmonomethyltindeterminationintoysbasedongastricjuicemigration
AT yilezhou experimentalandtheoreticalstudyonthefalsepositiveofmonomethyltindeterminationintoysbasedongastricjuicemigration
AT chenyang experimentalandtheoreticalstudyonthefalsepositiveofmonomethyltindeterminationintoysbasedongastricjuicemigration
AT matongmei experimentalandtheoreticalstudyonthefalsepositiveofmonomethyltindeterminationintoysbasedongastricjuicemigration