Cargando…

Poly(Hydroxyethyl Methacrylate) Immunoaffinity Cryogel Column for the Purification of Human Immunoglobulin M

Human immunoglobulin M (hIgM) antibodies are considered as hopeful tools for diseases therapy. Therefore, chromatography approaches are used to purify hIgM with a single step. In this study, we prepared a poly(hydroxyethyl methacrylate) based immunoaffinity p(HEMA-I) cryogel column by using cyanamid...

Descripción completa

Detalles Bibliográficos
Autores principales: Bakhshpour, Monireh, Topcu, Aykut Arif, Bereli, Nilay, Alkan, Huseyin, Denizli, Adil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7151037/
https://www.ncbi.nlm.nih.gov/pubmed/32013072
http://dx.doi.org/10.3390/gels6010004
_version_ 1783521157473894400
author Bakhshpour, Monireh
Topcu, Aykut Arif
Bereli, Nilay
Alkan, Huseyin
Denizli, Adil
author_facet Bakhshpour, Monireh
Topcu, Aykut Arif
Bereli, Nilay
Alkan, Huseyin
Denizli, Adil
author_sort Bakhshpour, Monireh
collection PubMed
description Human immunoglobulin M (hIgM) antibodies are considered as hopeful tools for diseases therapy. Therefore, chromatography approaches are used to purify hIgM with a single step. In this study, we prepared a poly(hydroxyethyl methacrylate) based immunoaffinity p(HEMA-I) cryogel column by using cyanamide to immobilize antihuman immunoglobulin on the p(HEMA) cryogel for purification of hIgM in aqueous solution and artificial human plasma. The characterization of the p(HEMA) cryogel column was performed by using a scanning electron microscope (SEM), micro-computerized tomography (µ-CT), Fourier transform infrared spectroscopy (FTIR), swelling degree and macro-porosity. Further, the optimizations of various parameters were performed such as, pH, ionic strength, temperature and concentration of hIgM in aqueous solutions. In addition, the Langmuir adsorption model was supported by experimental results. Maximum adsorbed amount of hIgM corresponded to 11.1 mg/g at pH 5.75 [morpholino ethanesulfonic acid (MES buffer)]. Our results indicated that the p(HEMA-I) cryogel column can be reused at least 10 times without significant loss in adsorption capacity. As a natural source, artificial human plasma was selected for hIgM adsorption and the purity of hIgM was evaluated using sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE).
format Online
Article
Text
id pubmed-7151037
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-71510372020-04-20 Poly(Hydroxyethyl Methacrylate) Immunoaffinity Cryogel Column for the Purification of Human Immunoglobulin M Bakhshpour, Monireh Topcu, Aykut Arif Bereli, Nilay Alkan, Huseyin Denizli, Adil Gels Article Human immunoglobulin M (hIgM) antibodies are considered as hopeful tools for diseases therapy. Therefore, chromatography approaches are used to purify hIgM with a single step. In this study, we prepared a poly(hydroxyethyl methacrylate) based immunoaffinity p(HEMA-I) cryogel column by using cyanamide to immobilize antihuman immunoglobulin on the p(HEMA) cryogel for purification of hIgM in aqueous solution and artificial human plasma. The characterization of the p(HEMA) cryogel column was performed by using a scanning electron microscope (SEM), micro-computerized tomography (µ-CT), Fourier transform infrared spectroscopy (FTIR), swelling degree and macro-porosity. Further, the optimizations of various parameters were performed such as, pH, ionic strength, temperature and concentration of hIgM in aqueous solutions. In addition, the Langmuir adsorption model was supported by experimental results. Maximum adsorbed amount of hIgM corresponded to 11.1 mg/g at pH 5.75 [morpholino ethanesulfonic acid (MES buffer)]. Our results indicated that the p(HEMA-I) cryogel column can be reused at least 10 times without significant loss in adsorption capacity. As a natural source, artificial human plasma was selected for hIgM adsorption and the purity of hIgM was evaluated using sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). MDPI 2020-01-29 /pmc/articles/PMC7151037/ /pubmed/32013072 http://dx.doi.org/10.3390/gels6010004 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bakhshpour, Monireh
Topcu, Aykut Arif
Bereli, Nilay
Alkan, Huseyin
Denizli, Adil
Poly(Hydroxyethyl Methacrylate) Immunoaffinity Cryogel Column for the Purification of Human Immunoglobulin M
title Poly(Hydroxyethyl Methacrylate) Immunoaffinity Cryogel Column for the Purification of Human Immunoglobulin M
title_full Poly(Hydroxyethyl Methacrylate) Immunoaffinity Cryogel Column for the Purification of Human Immunoglobulin M
title_fullStr Poly(Hydroxyethyl Methacrylate) Immunoaffinity Cryogel Column for the Purification of Human Immunoglobulin M
title_full_unstemmed Poly(Hydroxyethyl Methacrylate) Immunoaffinity Cryogel Column for the Purification of Human Immunoglobulin M
title_short Poly(Hydroxyethyl Methacrylate) Immunoaffinity Cryogel Column for the Purification of Human Immunoglobulin M
title_sort poly(hydroxyethyl methacrylate) immunoaffinity cryogel column for the purification of human immunoglobulin m
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7151037/
https://www.ncbi.nlm.nih.gov/pubmed/32013072
http://dx.doi.org/10.3390/gels6010004
work_keys_str_mv AT bakhshpourmonireh polyhydroxyethylmethacrylateimmunoaffinitycryogelcolumnforthepurificationofhumanimmunoglobulinm
AT topcuaykutarif polyhydroxyethylmethacrylateimmunoaffinitycryogelcolumnforthepurificationofhumanimmunoglobulinm
AT berelinilay polyhydroxyethylmethacrylateimmunoaffinitycryogelcolumnforthepurificationofhumanimmunoglobulinm
AT alkanhuseyin polyhydroxyethylmethacrylateimmunoaffinitycryogelcolumnforthepurificationofhumanimmunoglobulinm
AT denizliadil polyhydroxyethylmethacrylateimmunoaffinitycryogelcolumnforthepurificationofhumanimmunoglobulinm