A Two-Stage Framework for Automated Malignant Pulmonary Nodule Detection in CT Scans

This research is concerned with malignant pulmonary nodule detection (PND) in low-dose CT scans. Due to its crucial role in the early diagnosis of lung cancer, PND has considerable potential in improving the survival rate of patients. We propose a two-stage framework that exploits the ever-growing a...

Descripción completa

Detalles Bibliográficos
Autores principales: EL-Bana, Shimaa, Al-Kabbany, Ahmad, Sharkas, Maha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7151085/
https://www.ncbi.nlm.nih.gov/pubmed/32121281
http://dx.doi.org/10.3390/diagnostics10030131
_version_ 1783521168667443200
author EL-Bana, Shimaa
Al-Kabbany, Ahmad
Sharkas, Maha
author_facet EL-Bana, Shimaa
Al-Kabbany, Ahmad
Sharkas, Maha
author_sort EL-Bana, Shimaa
collection PubMed
description This research is concerned with malignant pulmonary nodule detection (PND) in low-dose CT scans. Due to its crucial role in the early diagnosis of lung cancer, PND has considerable potential in improving the survival rate of patients. We propose a two-stage framework that exploits the ever-growing advances in deep neural network models, and that is comprised of a semantic segmentation stage followed by localization and classification. We employ the recently published DeepLab model for semantic segmentation, and we show that it significantly improves the accuracy of nodule detection compared to the classical U-Net model and its most recent variants. Using the widely adopted Lung Nodule Analysis dataset (LUNA16), we evaluate the performance of the semantic segmentation stage by adopting two network backbones, namely, MobileNet-V2 and Xception. We present the impact of various model training parameters and the computational time on the detection accuracy, featuring a 79.1% mean intersection-over-union (mIoU) and an 88.34% dice coefficient. This represents a mIoU increase of 60% and a dice coefficient increase of 30% compared to U-Net. The second stage involves feeding the output of the DeepLab-based semantic segmentation to a localization-then-classification stage. The second stage is realized using Faster RCNN and SSD, with an Inception-V2 as a backbone. On LUNA16, the two-stage framework attained a sensitivity of 96.4%, outperforming other recent models in the literature, including deep models. Finally, we show that adopting a transfer learning approach, particularly, the DeepLab model weights of the first stage of the framework, to infer binary (malignant-benign) labels on the Kaggle dataset for pulmonary nodules achieves a classification accuracy of 95.66%, which represents approximately 4% improvement over the recent literature.
format Online
Article
Text
id pubmed-7151085
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-71510852020-04-20 A Two-Stage Framework for Automated Malignant Pulmonary Nodule Detection in CT Scans EL-Bana, Shimaa Al-Kabbany, Ahmad Sharkas, Maha Diagnostics (Basel) Article This research is concerned with malignant pulmonary nodule detection (PND) in low-dose CT scans. Due to its crucial role in the early diagnosis of lung cancer, PND has considerable potential in improving the survival rate of patients. We propose a two-stage framework that exploits the ever-growing advances in deep neural network models, and that is comprised of a semantic segmentation stage followed by localization and classification. We employ the recently published DeepLab model for semantic segmentation, and we show that it significantly improves the accuracy of nodule detection compared to the classical U-Net model and its most recent variants. Using the widely adopted Lung Nodule Analysis dataset (LUNA16), we evaluate the performance of the semantic segmentation stage by adopting two network backbones, namely, MobileNet-V2 and Xception. We present the impact of various model training parameters and the computational time on the detection accuracy, featuring a 79.1% mean intersection-over-union (mIoU) and an 88.34% dice coefficient. This represents a mIoU increase of 60% and a dice coefficient increase of 30% compared to U-Net. The second stage involves feeding the output of the DeepLab-based semantic segmentation to a localization-then-classification stage. The second stage is realized using Faster RCNN and SSD, with an Inception-V2 as a backbone. On LUNA16, the two-stage framework attained a sensitivity of 96.4%, outperforming other recent models in the literature, including deep models. Finally, we show that adopting a transfer learning approach, particularly, the DeepLab model weights of the first stage of the framework, to infer binary (malignant-benign) labels on the Kaggle dataset for pulmonary nodules achieves a classification accuracy of 95.66%, which represents approximately 4% improvement over the recent literature. MDPI 2020-02-28 /pmc/articles/PMC7151085/ /pubmed/32121281 http://dx.doi.org/10.3390/diagnostics10030131 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
EL-Bana, Shimaa
Al-Kabbany, Ahmad
Sharkas, Maha
A Two-Stage Framework for Automated Malignant Pulmonary Nodule Detection in CT Scans
title A Two-Stage Framework for Automated Malignant Pulmonary Nodule Detection in CT Scans
title_full A Two-Stage Framework for Automated Malignant Pulmonary Nodule Detection in CT Scans
title_fullStr A Two-Stage Framework for Automated Malignant Pulmonary Nodule Detection in CT Scans
title_full_unstemmed A Two-Stage Framework for Automated Malignant Pulmonary Nodule Detection in CT Scans
title_short A Two-Stage Framework for Automated Malignant Pulmonary Nodule Detection in CT Scans
title_sort two-stage framework for automated malignant pulmonary nodule detection in ct scans
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7151085/
https://www.ncbi.nlm.nih.gov/pubmed/32121281
http://dx.doi.org/10.3390/diagnostics10030131
work_keys_str_mv AT elbanashimaa atwostageframeworkforautomatedmalignantpulmonarynoduledetectioninctscans
AT alkabbanyahmad atwostageframeworkforautomatedmalignantpulmonarynoduledetectioninctscans
AT sharkasmaha atwostageframeworkforautomatedmalignantpulmonarynoduledetectioninctscans
AT elbanashimaa twostageframeworkforautomatedmalignantpulmonarynoduledetectioninctscans
AT alkabbanyahmad twostageframeworkforautomatedmalignantpulmonarynoduledetectioninctscans
AT sharkasmaha twostageframeworkforautomatedmalignantpulmonarynoduledetectioninctscans